Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Functional Modeling of 18-Pulse Autotransformer Rectifier Units for Aircraft Applications

2015-09-15
2015-01-2412
This paper aims to develop a general functional model of multi-pulse Auto-Transformer Rectifier Units (ATRUs) for More-Electric Aircraft (MEA) applications. The ATRU is seen as the most reliable way readily to be applied in the MEA. Interestingly, there is no model of ATRUs suitable for unbalanced or faulty conditions at the moment. This paper is aimed to fill this gap and develop functional models suitable for both balanced and unbalanced conditions. Using the fact that the DC voltage and current are strongly related to the voltage and current vectors at the AC terminals of ATRUs, a generic functional model has been developed for both symmetric and asymmetric ATRUs. The developed functional models are validated through simulation and experiment. The efficiency of the developed model is also demonstrated by comparing with corresponding detailed switching models. The developed functional model shows significant improvement of simulation efficiency, especially under balanced conditions.
Journal Article

Application of Dynamic Phasor Concept in Modeling Aircraft Electrical Power Systems

2013-09-17
2013-01-2083
As future commercial aircraft incorporates more EMAs, the aircraft electrical power system architecture will become a complex electrical distribution system with increased numbers of power electronic converters (PEC) and electrical loads. The overall system performance and the power management for on-board electrical loads are therefore key issues that need to be addressed. In order to understand these issues and identify high pay-off technologies that would enable a major improvement of the overall system performance, it is necessary to study the aircraft EPS at the system level. Due to the switching behaviour of power electronic devices, it is very time-consuming and even impractical to simulate a large-scale EPS with some non-linear and time-varying models. The dynamic phasor (DP) technique is one way to solve that problem.
Technical Paper

Application of Dynamic Phasors for Modeling of Active Front-End Converter for More-Electric Aircraft

2012-10-22
2012-01-2157
The paper deals with the development of active front-end rectifier model based on dynamic phasors concept. The model addresses the functional modeling level as defined by the multi-layer modeling paradigm and is suitable for accelerated simulation studies of the electric power systems under normal, unbalanced and line fault conditions. The performance and effectiveness of the developed model have been demonstrated by comparison against time-domain models in three-phase and synchronous space-vector representations. The experimental verification of the dynamic phasor model is also reported. The prime purpose of the model is for the simulation studies of more-electric aircraft power architectures at system level; however it can be directly applied for simulation study of any other electrical power system interfacing with active front-end rectifiers.
Technical Paper

Modeling of An 18-pulse Autotransformer Rectifier Unit with Dynamic Phasors

2012-10-22
2012-01-2159
The more-electric aircraft (MEA) is the major trend for airplanes in the next generation. Comparing with traditional airplanes, a significant increase of on-board electrical and electronic devices in MEAs has been recognized and resulted in new challenges for electrical power system (EPS) designers. The design of EPS essentially involves in extensive simulation work in order to ensure the availability, stability and performance of the EPS under all possible operation conditions. Due to the switching behavior of power electronic devices, it is very time-consuming and even impractical to simulate a large-scale EPS with some non-linear and time-varying models. The functional models in the dq0 frame have shown great performance under balanced conditions but these models become very time-consuming under unbalanced conditions, due to the second harmonics in d and q axes. The dynamic phasor (DP) technique has been proposed to solve that problem.