Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

Large-Eddy Simulation of a NACA23012 Airfoil under Clean and Iced Conditions

2023-06-15
2023-01-1483
Predicting the aerodynamic performance of an aircraft in icing conditions is critical as failures in an aircraft’s ice protection system can compromise flight safety. Aerodynamic effects of icing have typically relied on RANS modeling, which usually struggles to predict stall behavior, including those induced by surface roughness. Encouraged by recent studies using LES that demonstrate the ability to predict stall characteristics on full aircraft with smooth wings at an affordable cost [1], this study seeks to apply this methodology to icing conditions. Measurements of lift, drag, and pitching moments of a NACA23012 airfoil under clean and iced conditions are collected at Re = 1.8M. Using laser scanned, detailed representations of the icing geometries, LES calculations are conducted to compare integrated loads against experimental measurements in both clean and iced conditions at various angles of attack through the onset of stall [2].
Technical Paper

Crank-angle-resolved Measurements of Air-fuel Ratio, Temperature, and Liquid Fuel Droplet Scattering in a Direct-injection Gasoline Engine

2010-10-25
2010-01-2246
Simultaneous crank-angle-resolved measurements of gasoline vapor concentration, gas temperature, and liquid fuel droplet scattering were made with three-color infrared absorption in a direct-injection spark-ignition engine with premium gasoline. The infrared light was coupled into and out of the cylinder using fiber optics incorporated into a modified spark plug, allowing measurement at a location adjacent to the spark plug electrode. Two mid-infrared (mid-IR) laser wavelengths were simultaneously produced by difference-frequency-generation in periodically poled lithium niobate (PPLN) using one signal and two pump lasers operating in the near-infrared (near-IR). A portion of the near-IR signal laser residual provided a simultaneous third, non-resonant, wavelength for liquid droplet detection. This non-resonant signal was used to subtract the influence of droplet scattering from the resonant mid-IR signals to obtain vapor absorption signals in the presence of droplet extinction.
Journal Article

Two-Wavelength PLIF Diagnostic for Temperature and Composition

2008-04-14
2008-01-1067
Laser excitation wavelengths for two-line planar laser-induced fluorescence (PLIF) of 3-pentanone have been optimized for simultaneous imaging of temperature and composition under engine-relevant conditions. Validation of the diagnostic was performed in a motored optical IC engine seeded homogeneously with 3-pentanone. PLIF measurements of the uniform mixture during the compression stroke were used to measure the average temperature and to access the random uncertainty in the measurements. To determine the accuracy of the temperature measurements, experimental average temperatures were compared to values computed assuming isentropic compression and to the output of a tuned 1-D engine simulation. The comparison indicated that the absolute accuracy of the temperature measurements is better than ±5%. Probability density functions (PDFs) calculated from the single-shot images were used to estimate the precision of the measurements.
Technical Paper

Simultaneous Measurement of In-Cylinder Temperature and Residual Gas Concentration in the Vicinity of the Spark Plug by Wavelength Modulation Infrared Absorption

2007-04-16
2007-01-0639
This paper presents a new measurement technique for in-cylinder gas temperature and residual gas concentration during the compression stroke of an internal combustion (IC) engine. This technique is based on the infrared absorption of water vapor by a wavelength modulated laser. Wavelength modulation spectroscopy with second harmonic detection (WMS-2f) was adopted to enable the short-path measurements over a wide range of temperatures and pressures corresponding to the late compression stroke in a typical automotive engine. The WMS-2f signal is detected through a bandpass filter at a width of 7.5 kHz, enabling crank angle-resolved measurements. The temperature is determined from the ratio of optical absorption for two overtone transitions of water vapor in the intake gas mixture, and the H2O concentration is determined from this inferred temperature and the absorption for one of the transitions.
Technical Paper

Evaporating Spray Concentration Measurementsfrom Small and Medium Bore Diesel Injectors

2002-03-04
2002-01-0219
Vapor concentration measurements were performed for two unit injectors typically found in small- and medium-bore applications under evaporating conditions similar to those experienced in Diesel engines. Ambient gas temperatures of 800 and 1000 K and an ambient density of 15 kg/m3 were investigated using a constant volume combustion-type spray chamber. The exciplex laserinduced fluorescence technique with TMPD/naphthalene doped into the fuel was used to quantitatively determine the vapor-phase concentration and liquid-phase extent. The vapor-phase concentration was quantified using a previously developed method that includes corrections for the temperature dependence of the TMPD fluorescence, laser sheet absorption, and the laser sheet intensity profile. The effect of increasing ambient temperature (1000 vs. 800 K) was significant on intact liquid length, and on the spray-spreading angle in the early portion of the injection period.
Technical Paper

On the Calibration of Single-Shot Planar Laser Imaging Techniques in Engines

2002-03-04
2002-01-0748
The noise characteristics of four camera systems representative of those typically used for laser-imaging experiments (a back-illuminated slow-scan camera, a frame-straddling slow-scan camera, an intensified slow-scan camera and an intensified video-rate camera) were investigated, and the results are presented as a function of the signal level and illumination level. These results provide the maximum possible signal-to-noise ratio for laser-imaging experiments, and represent the limit of quantitative signal interpretation. A calibration strategy for engine data that limits the uncertainties associated with thermodynamic and optical correction was presented and applied to engine data acquired with two of the camera systems. When a rigorous analysis of the signal is performed it is seen that shot noise limits the quantitative interpretation of the data for most typical laser-imaging experiments, and obviates the use of single-pixel data.
Technical Paper

Characteristics of Air Flow Surrounding Non-Evaporating Transient Diesel Sprays

2000-10-16
2000-01-2789
Airflow characteristics surrounding non-evaporating transient diesel sprays were investigated using a 6-hole injector. Particle Image Velocimetry (PIV) was used to measure the gas velocities surrounding a spray plume as a function of space and time. A hydraulically actuated, electronically controlled unit injector (HEUI) system was used to supply the fuel into a pressurized constant volume chamber at room temperature. The chamber gas densities in this study were 10 kg/m3, 20 kg/m3 and 30 kg/m3. The injection pressure was 96.5 MPa. Two frequency doubled (532 nm) Nd:YAG lasers were used to create coincident laser sheets to illuminate the test section at two instances after start of injection (ASI). The double exposed images of sprays and Al2O3 seed particles were developed and velocity vectors of the gas surrounding the transient diesel sprays were obtained using a numerical autocorrelation PIV method.
Technical Paper

Air Entrainment in a High Pressure Diesel Spray

1997-05-01
971620
This paper presents some experimental results of air velocity measurements near high pressure diesel sprays. The measurements were made using a moderately high pressure (90 MPa) common rail injector in a pressurized spray chamber. The chamber was operated at ambient temperature (25°C) and was pressurized with Argon to produce a chamber gas density of about 27 kg/m3, similar to densities found in a large turbocharged diesel near TDC. The gas phase was tagged using water droplets doped with Stilbene 420, with an estimated droplet size of 18 μm. The atomized water-Stilbene droplets were illuminated with the third harmonic of a pair of Nd:YAG lasers which caused the Stilbene to fluoresce at about 420 nm. To reduce the competing fluorescence from the injected fuel, the injector was fueled with Jet-A fuel. Using the two lasers, double exposures of the small droplets were recorded on film. The laser pulse lengths were about 6 ns, and typical times between pulses were 100 μs.
Technical Paper

A Study on the Effects of Fuel Viscosity and Nozzle Geometry on High Injection Pressure Diesel Spray Characteristics

1997-02-24
970353
The objective of this study was to investigate the effects of fuel viscosity and the effects of nozzle inlet configuration on the characteristics of high injection pressure sprays. Three different viscosity fuels were used to reveal the effects of viscosity on the spray characteristics. The effects of nozzle inlet configuration on spray characteristics were studied using two mini-sac six-hole nozzles with different inlet configurations. A common rail injection system was used to introduce the spray at 90 MPa injection pressure into a constant volume chamber pressurized with argon gas. The information on high pressure transient sprays was captured by a high speed movie camera synchronized with a pulsed copper vapor laser. The images were analyzed to obtain the spray characteristics which include spray tip penetration, spray cone angle at two different regions, and overall spray Sauter Mean Diameter (SMD).
Technical Paper

Intake Valve Flow Measurements Using PIV

1993-10-01
932700
Intake valve flow patterns have been measured quantitatively using particle image velocimetry (PIV) for a commercial 4-valve diesel cylinder head and valve system. The measurements have been made for low (600 engine RPM) and higher (1000 engine RPM) speeds, and at several planes in the valve curtain area. The measurements involve double exposure photography of laser light scattered by seed particles (≅1 μm) from a laser light sheet (≅ 0.5 mm by 50 mm) through an imaging system onto silver halide film. Subsequent processing produces the local particle displacement between the two exposures. Combined with the known time interval between exposures, the displacement information can produce velocity vectors at many locations in the field of view. The results of the experiments are shown as vector plots for each operating condition. In the plane of the illuminating laser sheet, velocity vectors representing local gas velocity are produced.
X