Technical Paper

Theories, Facts and Issues About Recliner and Track Release of Front Seats in Rear Impacts

2018-04-03
2018-01-1329
Objective: This study involved a number of different tests addressing theories for recliner and track release of front seats in rear impacts. It addresses the validity of the theories. Method: Several separate test series were conducted to address claims made about recliner and track release of front seats in rear impacts. The following theories were evaluated to see the validity of the issues: 1 Recliner teeth slipping with minimal damage to the teeth 2 Recliner teeth bypass by disengaging and re-engaging under load without damaging the teeth 3 Recliner shaft bending and torque releasing the recliners 4 Track release by heel loading 5 Track release with occupant load on the seat 6 Recliner handle rotation causing recliner release 7 Double pull body block tests Results: Many of the theories were found to be uncorroborated once actual test data was available to judge the merits of the issue raised. The laboratory tests were set-up to specifically address particular issues.
Book

Occupant and Vehicle Responses in Rollovers

2004-03-08
During the past decade, there has been a steady increase in studies addressing rollover crashes and injuries. Though rollovers are not the most frequent crash type, they are significant with respect to serious injury and interest in rollovers has grown with the introduction of SUVs, vans, and light trucks. A review of Occupant and Vehicle Responses in Rollovers examines relevant conditions for field roll overs, vehicle responses, and occupant kinetics in the vehicle. This book edited by Dr. David C. Viano and Dr. Chantal S. Parenteau includes 62 technical documents covering 15 years of rollover crash safety, including field crash statistics, pre- and rollover dynamics, test procedures and dummy responses.
Technical Paper

Research Issues on the Biomechanics of Seating Discomfort: An Overview with Focus on Issues of the Elderly and Low-Back Pain

1992-02-01
920130
This paper reviews issues relating to seats including design for comfort and restraint, mechanics of discomfort and irritability, older occupants, and low-back pain. It focuses on the interface between seating technology and occupant comfort, and involves a technical review of medical-engineering information. The dramatic increase in the number of features currently available on seats outreaches the technical understanding of occupant accommodation and ride comfort. Thus, the current understanding of seat design parameters may not adequately encompass occupant needs. The review has found many pathways between seating features and riding comfort, each of which requires more specific information on the biomechanics of discomfort by pressure distribution, body support, ride vibration, material breathability, and other factors. These inputs stimulate mechanisms of discomfort that need to be quantified in terms of mechanical requirements for seat design and function.
Technical Paper

History of Safety Research and Development on the General Motors Energy-Absorbing Steering System

1991-10-01
912890
This paper covers the development of the General Motors Energy Absorbing Steering System beginning with the work of the early crash injury pioneers Hugh DeHaven and Colonel John P. Stapp through developments and introduction of the General Motors energy absorbing steering system in 1966. evaluations of crash performance of the system, and further improvement in protective function of the steering assembly. The contributions of GM Research Laboratories are highlighted, including its safety research program. Safety Car, Invertube, the biomechanic projects at Wayne State University, and the thoracic and abdominal tolerance studies that lead to the development of the Viscous Injury Criterion and self-aligning steering wheel.
Technical Paper

Biomechanics of Bone and Tissue: A Review of Material Properties and Failure Characteristics

1986-10-01
861923
This paper contains a review of current information on biological structure, material properties and failure characteristics of bone, articular cartilage, ligament and tendon. The load-deformation response of biological tissues is presented with particular reference to the microstructure of the material. Although many of the tissues have been characterized as linear, elastic and isotropic materials, they actually have a more complicated response to load, which includes stiffening with increasing strain, inelastic yield, and strain rate sensitivity. Failure of compact and cancellous bone depends on the rate, type, and direction of loading. Soft biological tissues are vlscoelastie and exhibit a higher load tolerance with an increasing rate of loading. The paper includes a discussion on the basic principles of biomechanics and emphasizes material properties and failure characteristics of biological tissues subjected to impact loading.
Technical Paper

Biomechanics of Nonpenetrating Aortic Trauma: A Review

1983-10-17
831608
Life threatening chest injury can involve partial or full tears of the aorta. Investigations of fatal injuries in automobile accidents indicate that aortic trauma occurs in 10-20% of the cases. The major sites of aortic trauma include the aortic isthmus, the root, and the aortic insertion at the diaphragm - all of which are points of aortic tethering. The biomechanics of the injury process involve stretching of the vessel from points of tethering and hydrodynamic increases in blood pressure, which stretch the tissue to failure at a strain of about 150%. The non-isotropic stretch response of aortic tissue is discussed with reference to the frequent transverse orientation of the laceration. Congenital and pathophysiological conditions also influence the failure characteristics of the tissue. The significant factors associated with traumatic injury of the aorta are discussed in this review paper which is based on published technical information.
Technical Paper

Critical Issues in Finite Element Modeling of Head Impact

1982-02-01
821150
Current finite element models of head impact involve a geometrically simplified fluid-filled shell composed of homogeneous, linear and (visco) elastic materials as the primary surrogate of the human skull and brain. The numerical procedure, which solves the mechanical response to impact, requires and presumes continuity of stress and displacement between elements, a defined boundary condition simulating the neck attachment and a known forcing function. Our critical review of the models discussed, primarily, the technical aspects of the approximations made to simulate the head and the limitations of the proposed analytical tools in predicting the response of biological tissue. The following critical features were identified as major factors which compromised the accuracy and objectivity of the models: - The brain was approximated by a fluid contained in an elastic or rigid shell with no provision for relative motion between the shell and fluid.
Technical Paper

Thoracic Impact Response of Live Porcine Subjects

1976-02-01
760823
Five anesthetized porcine subjects were exposed to blunt thoracic impact using a 21 kg mass with a flat contact surface traveling at 3.0 to 12.2 m/s. The experiments were conducted to assess the appropriateness of studying in vivo mechanical and physiological response to thoracic impact in a porcine animal model. A comprehensive review of comparative anatomy between the pig and man indicates that the cardiovascular, respiratory and thoracic skeletal systems of the pig are anatomically and functionally a good parallel of similar structures in man. Thoracic anthropometry measurements document that the chest of a 50 to 60 kg pig is similar to the 50th percentile adult male human, but is narrower and deeper. Peak applied force and chest deflection are in good agreement between the animal's responses and similar impact severity data on fresh cadavers.
Technical Paper

Significance of Rate of Onset in Impact Injury Evaluation

1975-02-01
751169
The concept of rate of onset as an injury potential index is critically discussed through the analysis of a wide range of noninjurious whole body decelerations and localized impacts. Examination of the physical data shows that extremely high rates of onset are tolerable without injury and that these levels of rate of onset are reciprocally dependent on the pulse rise time. The physical data is next discussed with reference to existing acceleration injury criteria, specifically the GSI and HIC indices. This work substantiates the conclusions that a single rate of onset tolerance level is not warranted and that rate of onset is not a proven injury potential index.