Refine Your Search

Search Results

Viewing 1 to 11 of 11
Technical Paper

Role of Environmental Factors in Immunity and Infectious Disease Risk

2005-07-11
2005-01-2763
Environmental monitoring of microbial contaminants is important for crew health and assessing functionality of engineering systems. Routine monitoring of air and surfaces on the International Space Station found Staphylococcus spp. to be the most common bacterial species whereas Aspergillus spp. were the most common fungi. The levels of microbial contaminants in the air and surfaces were typically low and within the acceptability limits. Bacterial levels in the potable water from the hot water port were uniformly low. Levels in water from the warm port and the SVO-ZV water distribution system exceeded acceptability limits on occasion. Methylobacterium spp. And Ralstonia spp. were the bacteria most commonly isolated from the potable water systems. The space environment, stress, and other factors may also diminish the host immune system. The status of antimicrobial functions of neutrophils and monocytes was determined by flow cytometry.
Technical Paper

Microbial Surveillance of Potable Water Sources of the International Space Station

2005-07-11
2005-01-2886
To mitigate risk to crew health, the microbial surveillance of the quality of potable water sources of the International Space Station (ISS) has been ongoing since before the arrival of the first permanent crew. These water sources have included stored ground-supplied water, water produced by the Shuttle fuel cells during flight, and ISS humidity condensate that is reclaimed and processed. In-flight monitoring was accomplished using a self-contained filtering system designed to allow bacterial growth and enumeration during flight. Upon return to Earth, microbial isolates were identified using 16S ribosomal gene sequencing. While the predominant isolates were common Gram negative bacteria including Ralstonia eutropha, Methylobacterium fujisawaense, and Sphingomonas paucimobilis, opportunistic pathogens such as Stenotrophomonas maltophilia and Pseudomonas aeruginosa were also isolated.
Technical Paper

Utilization of the Space Station Detergent IGEPON by a Candidate Organism for Use in a Space Biological Waste Reactor

1998-07-13
981608
The microgravity environment of space introduces a major new variable for consideration that will affect the design and operation of bioreactors. Adequate aeration for aerobic bioreactors will be a challenge as will gas/liquid separation, removal of carbon dioxide and other bacterial metabolic waste products, control algorithms, and overall performance assessment. These challenges must be addressed in order to fully assess the efficacy of biological approaches to the recovery of potable water from wastewater in microgravity. The first step in this process is to define the fermentation parameters of the organism or consortia that will be used in these space bioreactors. This study was designed to investigate the ability of bacteria to degrade the space station detergent IGEPON.
Technical Paper

Microbiology Standards for the International Space Station

1995-07-01
951682
The Crew Health System (CHeCS) plays a pivotal role in monitoring the life-support activities that maintain space station environmental quality and crew safety. Sampling hardware will be used in specific protocols to monitor the microbial dynamics of the closed spacecraft environment. NASA flight experience, ground-based studies, consultations with clinical and environmental microbiologists, and panel discussions with experts in engineering, flight-crew operations, microbiology, toxicology, and water quality systems all have been integral to the revision of in-flight microbial standards. The new standards for air and internal surfaces differentiate between bacterial and fungal loads, unlike previous standards that relied on total microbial counts. Microorganisms that must not be present in air or water or on surfaces also are listed.
Technical Paper

Microbiological Analysis of Water in Space

1995-07-01
951683
One of the proposed methods for monitoring the microbial quality of the water supply aboard the International Space Station is membrane filtration. We adapted this method for space flight by using an off-the-shelf filter unit developed by Millipore. This sealed unit allows liquid to be filtered through a 0.45 μm cellulose acetate filter that sits atop an absorbent pad to which growth medium is added. We combined a tetrazolium dye with R2A medium to allow microbial colonies to be seen easily, and modified the medium to remain stable over 70 weeks at 25°C. This hardware was assembled and tested in the laboratory and during parabolic flight; a modified version was then flown on STS-66. After the STS-66 mission, a back-up plastic syringe and an all-metal syringe pump were added to the kit, and the hardware was used successfully to evaluate water quality aboard the Russian Mir space station.
Technical Paper

Evaluation of Methods for Remediating Biofilms in Spacecraft Potable Water Systems

1994-06-01
941388
Controlling microbial growth and biofilm formation in spacecraft water-distribution systems is necessary to protect the health of the crew. Methods to decontaminate the water system in flight may be needed to support long-term missions. We evaluated the ability of iodine and ozone to kill attached bacteria and remove biofilms formed on stainless steel coupons. The biofilms were developed by placing the coupons in a manifold attached to the effluent line of a simulated spacecraft water-distribution system. After biofilms were established, the coupons were removed and placed in a treatment manifold in a separate water treatment system where they were exposed to the chemical treatments for various periods. Disinfection efficiency over time was measured by counting the bacteria that could be recovered from the coupons using a sonication and plate count technique. Scanning electron microscopy was also used to determine whether the treatments actually removed the biofilm.
Technical Paper

Disinfectants for Spacecraft Applications: An Overview

1991-07-01
911516
In-flight contamination control has been an important concern of NASA since the first manned missions. Previous experience has shown that uncontrolled growth of bacteria and fungi can have a detrimental effect on both the health of the crew and the proper operation of flight hardware. It is therefore imperative to develop a safe, effective method of microbial control. Spacecraft application dictates a more stringent set of requirements for biocide selection than is usually necessary for terrestrial situations. Toxicity of the biocide is the driving factor for disinfectant choice in spacecraft. This concern greatly reduces the number and types of chemical agents that can be used as disinfectants. Currently, four biocide candidates (hydrogen peroxide, quaternary ammonium compounds, iodine, glutaraldehyde) are being evaluated as potential surface disinfectants for Space Station Freedom.
Technical Paper

Biofilm Formation and Control in a Simulated Spacecraft Water System: Two-Year Results

1991-07-01
911403
The ability of iodine to maintain microbial water quality in a simulated spacecraft water system is being studied. An iodine level of about 2.0 mg/L is maintained by passing ultrapure influent water through an iodinated ion exchange resin. Six liters are withdrawn daily and the chemical and microbial quality of the water is monitored regularly. Stainless steel coupons used to monitor biofilm formation are being analyzed by culture methods, epifluorescence microscopy, and scanning electron microscopy. Results from the first two years of operation show a single episode of high bacterial colony counts in the iodinated system. This growth was apparently controlled by replacing the iodinated ion exchange resin. Scanning electron microscopy indicates that the iodine has limited but not completely eliminated the formation of biofilm during the first two years of operation.
Technical Paper

Development Program for a Zero-G Whole Body Shower

1987-09-01
871522
In 1985, the Man-Systems Division at the Johnson Space Center initiated a program for the development of a whole body shower suitable for operation in a microgravity environment. Supporting this development effort has been a systematic research program focused on four critical aspects of the design (i.e., human factors engineering, biomedical, mechanical, and electrical) and on the interfaces between the whole body shower system and the other systems to be aboard the Space Station (e.g., the water reclamation and air revitalization systems). A series of tests has been conducted to help define the design requirements for the whole body shower. Crew interface research has identified major design parameters related to enclosure configurations, consumable quantities, operation timelines, displays and controls, and shower and cleanup protocols.
Technical Paper

Test Results of a Shower Water Recovery System

1987-07-01
871512
A shower test was conducted recently at NASA-JSC in which waste water was reclaimed and reused. Test subjects showered in a prototype whole body shower following a protocol similar to that anticipated for Space Station. The waste water was purified using reverse osmosis followed by filtration through activated carbon and ion exchange resin beds. The reclaimed waste water was maintained free of microorganisms by using both heat and iodine. This paper discusses the test results, including the limited effectiveness of using iodine as a disinfectant and the evaluation of a Space Station candidate soap for showering. In addition, results are presented on chemical and microbial impurity content of water samples obtained from various locations in the water recovery process.
Technical Paper

Results on Reuse of Reclaimed Shower Water

1986-07-14
860983
A microgravity whole body shower (WBS) and a waste water recovery system (WWRS) were used in a closed loop test at the Johnson Space Center. The WWRS process involved chemical pretreatment, phase change distillation and post-treatment. A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem (TIMES) was used for distillation after pretreatment and the post-treatment was accomplished with activated carbon, mixed ion exchange resin beds and microbial check valve (MCV) iodine bactericide dispensing units. The purposes of this test were to evaluate a NASA approved Shuttle soap for whole body showering comfort; evaluate the effects of the shower water on the WBS and the TIMES; and evaluate purification qualities of the recovered water in a closed loop operation.
X