Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

DC Arc Fault Detection Methods in MEA Distribution Systems

2018-10-30
2018-01-1934
Direct current (DC) for primary power distribution is a promising solution that is being explored by aircraft system integrators for MEA applications to enable the paralleling of non-synchronized engine off-take generators, and to enable the reduction of energy conversion stages required to supply electronically actuated loads. However, a significant challenge in the use of DC systems is the reliable detection of arc faults. Arcing presents a significant fire risk to aircraft and their presence can result in critical system damage and potentially fatal conditions. Series arc faults in DC systems are particularly challenging to detect as the associated reduction in system current eliminates the use of conventional overcurrent and current differential methods for fault detection. This paper provides an overview of series arc faults in DC systems and presents both simulation and hardware results to illustrate key trends, characteristics and discriminating features.
Technical Paper

AC/DC Converter with DC Fault Suppression for Aircraft +/− 270 VDC Distribution Systems

2015-09-15
2015-01-2411
The increasing electrical demand in commercial and military aircraft justifies a growing need for higher voltage DC primary distribution systems. A DC system offers reduced power losses and space savings, which is of major importance for aircraft manufacturers. At present, challenges associated with DC systems include reliable fast acting short circuit protection. Solid State Contactors (SSC) have gained wide acceptance in traditional 28 VDC secondary systems for DC fault interruption. However, the reliable operation at higher operating voltages and currents requires further technology maturation. This paper examines a supporting method to SSC for more reliable fault mitigation by investigating bidirectional AC/DC converter topology with DC fault current blocking capability. Replacement of semiconductor switches with full bridge cells allows instant reversal of voltage polarities to limit rapid capacitor discharge and machine inductive currents.
Technical Paper

Failure Analysis of a Turboelectric Distributed Propulsion Aircraft Electrical Network: A Case Study

2015-09-15
2015-01-2403
A number of concepts have been proposed to meet future aircraft performance goals. One such concept under consideration is Turboelectric Distributed Propulsion (TeDP) featuring a large number of superconducting motors powered by two superconducting generators placed on each wingtip and connected through a DC distribution network. A key aspect in any design concept is the ability to prove that the system will exhibit a satisfactory reliability for all intended operating conditions. A common tool to support the calculation of failure rates and reliability is Fault Tree Analysis (FTA), and this will be utilized within this paper. The paper undertakes an architectural level FTA on a NASA proposed TeDP architecture to identify any significant factors contributing to the failure rate of key functionalities within the network.
Journal Article

Impact of Engine Certification Standards on the Design Requirements of More-Electric Engine Electrical System Architectures

2014-09-16
2014-01-2119
The development of the More-Electric Engine (MEE) concept will see an expansion in the power levels, functionality and criticality of electrical systems within engines. However, to date, these more critical electrical systems have not been accounted for in existing engine certification standards. To begin to address this gap, this paper conducts a review of current engine certification standards in order to determine how these standards will impact on the design requirements of More-Electric Engine (MEE) electrical system architectures. The paper focuses on determining two key architectural requirements: the number of individual failures an architecture can accommodate and still remain functional and the rate at which these failures are allowed to occur.
Journal Article

A Method for the Evaluation of the Effectiveness of Turboelectric Distributed Propulsion Power System Architectures

2014-09-16
2014-01-2120
Radical new electrically propelled aircraft are being considered to meet strict future performance goals. One concept design proposed is a Turboelectric Distributed Propulsion (TeDP) aircraft that utilises a number of electrically driven propulsors. Such concepts place a new and significant reliance on an aircraft's electrical system for safe and efficient flight. Accordingly, in addition to providing certainty that supply reliability targets are being met, a contingency analysis, evaluating the probability of component failure within the electrical network and the impact of that failure upon the available thrust must also be undertaken for architecture designs. Solutions that meet specified thrust requirements at a minimum associated weight are desired as these will likely achieve the greatest performance against the proposed emissions targets.
Technical Paper

Average-Value Diode Rectifier Modeling for Aerospace Applications

2011-10-18
2011-01-2621
Modern aerospace power systems commonly make use of uncontrolled rectifiers to satisfy many power conversion needs on board the aircraft. Whilst being highly accurate, an analytically detailed simulation of the aircraft power system, which includes all electric machine dynamics, semiconductor switching states, and power system dynamics, is often very computationally demanding. Average-value models of power electronic converters, with their reduced computational requirement, offer one potential solution to this issue. However, of the many converter topologies presented in the literature, average-value models of uncontrolled diode rectifiers are perhaps the most challenging to develop. The dependence of the rectifier's operating state on its loading conditions and the surrounding network topology complicates the derivation of average-value models.
X