Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Brain Strain from Motion of Sparse Markers

2020-03-31
2019-22-0001
Brain strain secondary to head impact or inertial loading is closely associated with pathologic observations in the brain. The only experimental brain strain dataset under loadings close to traumatic levels was calculated by imposing the experimentally measured motion of markers embedded in the brain to an auxiliary model formed by triad elements (Hardy et al., 2007). However, fidelity of the calculated strain as well as the suitability of using triad elements for three-dimensional (3D) strain estimation remains to be verified. Therefore, this study proposes to use tetrahedron elements as a new approach to estimate the brain strain. Fidelity of this newly-proposed approach along with the previous triad-based approach is evaluated with the aid of three independently-developed finite element (FE) head models by numerically replicating the experimental impacts and strain estimation procedures.
Technical Paper

A Reanalysis of Experimental Brain Strain Data: Implication for Finite Element Head Model Validation

2018-11-12
2018-22-0007
Relative motion between the brain and skull and brain deformation are biomechanics aspects associated with many types of traumatic brain injury (TBI). Thus far, there is only one experimental endeavor (Hardy et al., 2007) reported brain strain under loading conditions commensurate with levels that were capable of producing injury. Most of the existing finite element (FE) head models are validated against brain-skull relative motion and then used for TBI prediction based on strain metrics. However, the suitability of using a model validated against brain-skull relative motion for strain prediction remains to be determined. To partially address the deficiency of experimental brain deformation data, this study revisits the only existing dynamic experimental brain strain data and updates the original calculations, which reflect incremental strain changes. The brain strain is recomputed by imposing the measured motion of neutral density target (NDT) to the NDT triad model.
Technical Paper

Kinematics Response of the PMHS Brain to Rotational Loading of the Head: Development of Experimental Methods and Analysis of Preliminary Data

2018-04-03
2018-01-0547
Experimentally derived brain response envelopes are needed to evaluate and validate existing finite element (FE) head models. Motion of the brain relative to the skull during rotational input was measured using high-speed biplane x-ray. To generate repeatable, reproducible, and scalable data, methods were developed to reduce experimental variance. An “extreme-energy” device was developed to provide a controlled input that is unaffected by specimen characteristics. Additionally, a stereotactic frame was used to deploy radiopaque markers at specific, pre-determined locations within the brain. One post-mortem human surrogate (PMHS) head specimen was subjected to repeat tests of a half-sine rotational speed pulse in the sagittal plane. The desired pulse had a peak angular speed of 40 rad/s and duration of 30 ms. Relative motion of the brain was quantified using radiopaque targets and high-speed biplane x-ray. Frontal and occipital intracranial pressure (ICP) were also measured.
Technical Paper

Characterizing Vehicle Occupant Body Dimensions and Postures Using a Statistical Body Shape Model

2017-03-28
2017-01-0497
Reliable, accurate data on vehicle occupant characteristics could be used to personalize the occupant experience, potentially improving both satisfaction and safety. Recent improvements in 3D camera technology and increased use of cameras in vehicles offer the capability to effectively capture data on vehicle occupant characteristics, including size, shape, posture, and position. In previous work, the body dimensions of standing individuals were reliably estimated by fitting a statistical body shape model (SBSM) to data from a consumer-grade depth camera (Microsoft Kinect). In the current study, the methodology was extended to consider seated vehicle occupants. The SBSM used in this work was developed using laser scan data gathered from 147 children with stature ranging from 100 to 160 cm and BMI from 12 to 27 kg/m2 in various sitting postures.
Technical Paper

Evaluation of the Kinematic Responses and Potential Injury Mechanisms of the Jejunum during Seatbelt Loading

2015-11-09
2015-22-0009
High-speed biplane x-ray was used to research the kinematics of the small intestine in response to seatbelt loading. Six driver-side 3-point seatbelt simulations were conducted with the lap belt routed superior to the pelvis of six unembalmed human cadavers. Testing was conducted with each cadaver perfused, ventilated, and positioned in a fixed-back configuration with the spine angled 30° from the vertical axis. Four tests were conducted with the cadavers in an inverted position, and two tests were conducted with the cadavers upright. The jejunum was instrumented with radiopaque markers using a minimally-invasive, intraluminal approach without inducing preparation-related damage to the small intestine. Tests were conducted at a target peak lap belt speed of 3 m/s, resulting in peak lap belt loads ranging from 5.4-7.9 kN. Displacement of the radiopaque markers was recorded using high-speed x-ray from two perspectives.
Technical Paper

Development and Validation of an Older Occupant Finite Element Model of a Mid-Sized Male for Investigation of Age-related Injury Risk

2015-11-09
2015-22-0014
The aging population is a growing concern as the increased fragility and frailty of the elderly results in an elevated incidence of injury as well as an increased risk of mortality and morbidity. To assess elderly injury risk, age-specific computational models can be developed to directly calculate biomechanical metrics for injury. The first objective was to develop an older occupant Global Human Body Models Consortium (GHBMC) average male model (M50) representative of a 65 year old (YO) and to perform regional validation tests to investigate predicted fractures and injury severity with age. Development of the GHBMC M50 65 YO model involved implementing geometric, cortical thickness, and material property changes with age. Regional validation tests included a chest impact, a lateral impact, a shoulder impact, a thoracoabdominal impact, an abdominal bar impact, a pelvic impact, and a lateral sled test.
Technical Paper

Comparison of ATD to PMHS Response in the Under-Body Blast Environment

2015-11-09
2015-22-0017
A blast buck (Accelerative Loading Fixture, or ALF) was developed for studying underbody blast events in a laboratory-like setting. It was designed to provide a high-magnitude, high-rate, vertical loading environment for cadaver and dummy testing. It consists of a platform with a reinforcing cage that supports adjustable-height rigid seats for two crew positions. The platform has a heavy frame with a deformable floor insert. Fourteen tests were conducted using fourteen PMHS (post mortem human surrogates) and the Hybrid III ATD (Anthropomorphic Test Device). Tests were conducted at two charge levels: enhanced and mild. The surrogates were tested with and without PPE (Personal Protective Equipment), and in two different postures: nominal (knee angle of 90°) and obtuse (knee angle of 120°). The ALF reproduces damage in the PMHS commensurate with injuries experienced in theater, with the most common damage being to the pelvis and ankle.
Technical Paper

Response and Tolerance of Female and/or Elderly PMHS to Lateral Impact

2014-11-10
2014-22-0015
Eight whole fresh-frozen cadavers (6 female, 2 male) that were elderly and/or female were laterally impacted using UMTRI's dual-sled side-impact test facility. Cadavers were not excluded on the basis of old age or bone diseases that affect tolerance. A thinly padded, multi-segment impactor was used that independently measured force histories applied to the shoulder, thorax, abdomen, greater trochanter, iliac wing, and femur of each PMHS. Impactor plates were adjusted vertically and laterally toward the subject so that contact with body regions occurred simultaneously and so that each segment contacted the same region on every subject. This configuration minimized the effects of body shape on load sharing between regions. Prior to all tests, cadavers were CT scanned to check for pre-existing skeletal injuries. Cadavers were excluded if they had pre-existing rib fractures or had undergone CPR.
Technical Paper

PMHS Impact Response in 3 m/s and 8 m/s Nearside Impacts with Abdomen Offset

2013-11-11
2013-22-0015
Lateral impact tests were performed using seven male post-mortem human subjects (PMHS) to characterize the force-deflection response of contacted body regions, including the lower abdomen. All tests were performed using a dual-sled, side-impact test facility. A segmented impactor was mounted on a sled that was pneumatically accelerated into a second, initially stationary sled on which a subject was seated facing perpendicular to the direction of impact. Positions of impactor segments were adjusted for each subject so that forces applied to different anatomic regions, including thorax, abdomen, greater trochanter, iliac wing, and thigh, could be independently measured on each PMHS. The impactor contact surfaces were located in the same vertical plane, except that the abdomen plate was offset 5.1 cm towards the subject.
Journal Article

Development of a Methodology for Simulating Seat Back Interaction Using Realistic Body Contours

2013-04-08
2013-01-0452
Seat comfort is driven in part by the fit between the sitter and seat. Traditional anthropometric data provide little information about the size and shape of the torso that can be used for backrest design. This study introduces a methodology for using three-dimensional computer models of the human torso based on a statistical analysis of body shapes for conducting automated fit assessments. Surface scan data from 296 men and 417 women in a seated posture were analyzed to create a body shape model that can be adjusted to a range of statures, body shape, and postures spanning those typical of vehicle occupants. Finite-element models of two auto seat surface were created, along with custom software that generates body models and postures them in the seat. A simple simulation technique was developed to rapidly assess the fit of the torso relative to the seat back.
Technical Paper

Kinematics of the Thoracoabdominal Contents Under Various Loading Scenarios

2012-10-29
2012-22-0001
High-speed biplane x-ray was used to investigate relative kinematics of the thoracoabdominal organs in response to blunt loading. Four post-mortem human surrogates instrumented with radiopaque markers were subjected to eight crash-specific loading scenarios, including frontal chest and abdominal impacts, as well as driver-shoulder seatbelt loading. Testing was conducted with each surrogate perfused, ventilated, and positioned in an inverted, fixed-back configuration. Displacement of radiopaque markers recorded with high-speed x-ray in two perspectives was tracked using motion analysis software and projected into calibrated three-dimensional coordinates. Internal organ kinematics in response to blunt impact were quantified for the pericardium, lungs, diaphragm, liver, spleen, stomach, mesentery, and bony structures.
Technical Paper

Understanding Work Task Assessment Sensitivity to the Prediction of Standing Location

2011-04-12
2011-01-0527
Digital human models (DHM) are now widely used to assess worker tasks as part of manufacturing simulation. With current DHM software, the simulation engineer or ergonomist usually makes a manual estimate of the likely worker standing location with respect to the work task. In a small number of cases, the worker standing location is determined through physical testing with one or a few workers. Motion capture technology is sometimes used to aid in quantitative analysis of the resulting posture. Previous research has demonstrated the sensitivity of work task assessment using DHM to the accuracy of the posture prediction. This paper expands on that work by demonstrating the need for a method and model to accurately predict worker standing location. The effect of standing location on work task posture and the resulting assessment is documented through three case studies using the Siemens Jack DHM software.
Technical Paper

Validation of the Human Motion Simulation Framework: Posture Prediction for Standing Object Transfer Tasks

2009-06-09
2009-01-2284
The Human Motion Simulation Framework is a hierarchical set of algorithms for physical task simulation and analysis. The Framework is capable of simulating a wide range of tasks, including standing and seated reaches, walking and carrying objects, and vehicle ingress and egress. In this paper, model predictions for the terminal postures of standing object transfer tasks are compared to data from 20 subjects with a wide range of body dimensions. Whole body postures were recorded using optical motion capture for one-handed and two-handed object transfers to target destinations at three angles from straight ahead and three heights. The hand and foot locations from the data were input to the HUMOSIM Framework Reference Implementation (HFRI) in the Jack human modeling software. The whole-body postures predicted by the HFRI were compared to the measured postures using a set of measures selected for their importance to ergonomic analysis.
Technical Paper

Comparison of ATD and Driver Knee Positions

2009-04-20
2009-01-0390
Contact between the knees and knee bolster commonly occurs in frontal collisions. The contact region on the bolster and the knee anatomy involved are related to the pre-crash positioning of the knees. The location of the distal (or infra-) patella was recorded on volunteers of widely varying stature after they had selected a comfortable driving position in mockups of three vehicles representing a large variation in size and shape: sedan, crossover SUV, and full-size pickup. On average, the right knees were grouped more tightly and were located more forward and lower than the left knees. On average, the knees were positioned 200 mm from the knee bolster for all subjects. The range of distance separating the distal patellae (within subject knee-to-knee distance) varied from 184–559 mm for all subjects for the three vehicles.
Technical Paper

Investigation of Upper Body and Cervical Spine Kinematics of Post Mortem Human Subjects (PMHS) during Low-Speed, Rear-End Impacts

2009-04-20
2009-01-0387
A total of eight low-speed, rear-end impact tests using two Post Mortem Human Subjects (PMHS) in a seated posture are reported. These tests were conducted using a HYGE-style mini-sled. Two test conditions were employed: 8 kph without a headrestraint or 16 kph with a headrestraint. Upper-body kinematics were captured for each test using a combination of transducers and high-speed video. A 3-2-2-2-accelerometer package was used to measure the generalized 3D kinematics of both the head and pelvis. An angular rate sensor and two single-axis linear accelerometers were used to measure angular speed, angular acceleration, and linear acceleration of T1 in the sagittal plane. Two high-speed video cameras were used to track targets rigidly attached to the head, T1, and pelvis. The cervical spine kinematics were captured with a high-speed, biplane x-ray system by tracking radiopaque markers implanted into each cervical vertebra.
Technical Paper

Interactions of Out-of-Position Small-Female Surrogates with a Depowered Driver Airbag

2008-11-03
2008-22-0008
The objectives of this study were to examine the response, repeatability, and injury predictive ability of the Hybrid III small-female dummy to static out-of-position (OOP) deployments using a depowered driver-side airbag. Five dummy tests were conducted in two OOP configurations by two different laboratories. The OOP configurations were nose-on-rim (NOR) and chest-on-bag (COB). Four cadaver tests were conducted using unembalmed small-female cadavers and the same airbags used in the dummy tests under similar OOP conditions. One cadaver test was designed to increase airbag loading of the face and neck (a forehead-on-rim, or FOR test). Comparison between the dummy tests of Lab 1 and of Lab 2 indicated the test conditions and results were repeatable. In the cadaver tests no skull fractures or neck injuries occurred. However, all four cadavers had multiple rib fractures.
Technical Paper

Characterization of Knee-Thigh-Hip Response in Frontal Impacts Using Biomechanical Testing and Computational Simulations

2008-11-03
2008-22-0017
Development and validation of crash test dummies and computational models that are capable of predicting the risk of injury to all parts of the knee-thigh-hip (KTH) complex in frontal impact requires knowledge of the force transmitted from the knee to the hip under knee impact loading. To provide this information, the knee impact responses of whole and segmented cadavers were measured over a wide range of knee loading conditions. These data were used to develop and help validate a computational model, which was used to estimate force transmitted to the cadaver hip. Approximately 250 tests were conducted using five unembalmed midsize male cadavers. In these tests, the knees were symmetrically impacted with a 255-kg padded impactor using three combinations of knee-impactor padding and velocity that spanned the range of knee loading conditions produced in FMVSS 208 and NCAP tests. Each subject was tested in four conditions.
Technical Paper

Modeling Vehicle Ingress and Egress Using the Human Motion Simulation Framework

2008-06-17
2008-01-1896
The ease of getting into and out of passenger cars and light trucks is a critical component of customer acceptance and product differentiation. In commercial vehicles, the health and safety of drivers is affected by the design of the steps and handholds they use to get into and out of the cab. Ingress/egress assessment appears to represent a substantial application opportunity for digital human models. The complexity of the design space and the range of possible biomechanical and subjective measures of interest mean that developing useful empirical models is difficult, requiring large-scale subject testing with physical mockups. Yet, ingress and egress motions are complex and strongly affected by the geometric constraints and driver attributes, posing substantial challenges in creating meaningful simulations using figure models.
Journal Article

Postural Behaviors during One-Hand Force Exertions

2008-06-17
2008-01-1915
Posture and external loads such as hand forces have a dominant effect on ergonomic analysis outcomes. Yet, current digital human modeling tools used for proactive ergonomics analysis lack validated models for predicting postures for standing hand-force exertions. To address this need, the effects of hand magnitude and direction on whole-body posture for standing static hand-force exertion tasks were quantified in a motion-capture study of 19 men and women with widely varying body size. The objective of this work was to identify postural behaviors that might be incorporated into a posture-prediction algorithm for standing hand-force tasks. Analysis of one-handed exertions indicates that, when possible, people tend to align their bodies with the direction of force application, converting potential cross-body exertions into sagittal plane exertions. With respect to the hand-force plane, pelvis position is consistent with a postural objective of reducing rotational trunk torques.
Technical Paper

A Study of the Response of the Human Cadaver Head to Impact

2007-10-29
2007-22-0002
High-speed biplane x-ray and neutral density targets were used to examine brain displacement and deformation during impact. Relative motion, maximum principal strain, maximum shear strain, and intracranial pressure were measured in thirty-five impacts using eight human cadaver head and neck specimens. The effect of a helmet was evaluated. During impact, local brain tissue tends to keep its position and shape with respect to the inertial frame, resulting in relative motion between the brain and skull and deformation of the brain. The local brain motions tend to follow looping patterns. Similar patterns are observed for impact in different planes, with some degree of posterior-anterior and right-left symmetry. Peak coup pressure and pressure rate increase with increasing linear acceleration, but coup pressure pulse duration decreases. Peak average maximum principal strain and maximum shear are on the order of 0.09 for CFC 60 Hz data for these tests.
X