Refine Your Search

Search Results

Standard

Filler Pipes and Openings of Motor Vehicle Fuel Tanks

2019-10-02
CURRENT
J1140_201910
This SAE Recommended Practice was developed primarily for gasoline-powered passenger car and truck applications to interface vapor recovery systems, but may be used in diesel applications, marine, industrial, and similar applications where a nozzle is required for filling. The zones cover nozzle spout access and handle clearance to a refilling port. In addition, this practice includes a design window for nozzle manufacturers to develop with.
Standard

Dispenser Nozzle Spouts for Liquid Fuels Intended for Use with Spark Ignition and Compression Ignition Engines

2019-04-29
CURRENT
J285_201904
This SAE Recommended Practice provides standard dimensions for liquid fuel dispenser nozzle spouts and a system for differentiating between nozzles that dispense liquid fuel into vehicles with spark ignition (SI) engines and compression ignition (CI) engines for land vehicles. Current legal definitions only distinguish between “Unleaded Fuel” and “All Other Types of Fuel.” These definitions are no longer valid. This document establishes a new set of definitions that have practical application to current automobile liquid fuel inlets and liquid fuel dispenser nozzle spouts.
Standard

Fuel Tank Filler, Capless Closure

2019-04-24
CURRENT
J3144_201904
This SAE Recommended Practice was developed primarily for passenger car and truck applications, but it may be used in marine, industrial, and similar applications.
Standard

Fuel Tank Filler Cap and Cap Retainer

2019-04-24
CURRENT
J829_201904
This SAE Standard was developed primarily for passenger car and truck applications for the sizes indicated, but it may be used in marine, industrial, and similar applications.
Standard

Fuel Tank Filler Cap and Cap Retainer Threaded

2019-04-24
CURRENT
J1114_201904
This SAE Recommended Practice was developed primarily for passenger car and truck applications, but it may be used in marine, industrial, and similar applications.
Standard

Test Procedure to Measure the Fuel Permeability of Materials by the Cup Weight Loss Method

2018-12-12
CURRENT
J2665_201812
This test standard covers the procedure for measuring the permeation of fuel or fuel surrogates through test samples of elastomeric, plastic or composite materials, up to about 3 mm thick. The method involves filling a test cup with the test fluid (fuel or fuel surrogate), sealing test sample over the open end of the cup, and then placing the sealed container into an oven at the desired test temperature and measuring the weight loss over time. Permeation rates are calculated from the rate of weight loss and the exposed area of the test sample. Standard permeation test temperatures are 40 °C and 60 °C. Standard test fluids are Fuel C, Fuel CE10 and Fuel CM15. Other fluids, such as Fuel CMTBE15, and other volatile liquids may be tested according to this procedure as desired (SAE J1681). The method is not applicable for measuring permeation of higher boiling materials that will not completely evaporate from the exterior surface of the sample at the test temperature.
Standard

Rated (Advertised) Fuel Capacity - Passenger Car, Multi-Purpose Passenger Vehicles, and Light Duty Trucks

2012-11-01
CURRENT
J398_201211
This recommended practice provides a method for establishing the rated or advertised fuel capacity for a vehicle utilizing liquid fuel at atmospheric pressure. It applies to passenger cars, multi-purpose passenger vehicles and light duty trucks (10 000 lb (4536 kg) maximum GVW), (Ref. SAE J1100). It also includes a standardized procedure for creating a full tank when another test requires that condition as a starting point. It is intended as a guide toward standard practice and is subject to change to keep pace with experience and technical advances.
Standard

Fuel Tank Filler Cap and Cap Retainer

2012-06-29
HISTORICAL
J829_201206
This SAE Standard was developed primarily for passenger car and truck applications for the sizes indicated, but it may be used in marine, industrial, and similar applications.
Standard

Dispenser Nozzle Spouts for Liquid Fuels Intended for Use with Spark Ignition and Compression Ignition Engines

2012-05-31
HISTORICAL
J285_201205
This SAE recommended practice provides standard dimensions for liquid fuel dispenser nozzle spouts and a system for differentiating between nozzles that dispense liquid fuel into vehicles with Spark Ignition (SI) Engines and Compression Ignition (CI) Engines for land vehicles. Current legal definitions only distinguish between “UNLEADED Fuel” and “All Other Types of Fuel.” These definitions are no longer valid. This document establishes a new set of definitions that have practical application to current automobile liquid fuel inlets and liquid fuel dispenser nozzle spouts.
Standard

Requirements for Built-In Service Port for On Board Diagnostics

2008-08-11
HISTORICAL
J2744_200808
This document presents the requirements for a built-in service port to be used in vehicles intended to comply with Enhanced Evaporative Emissions Requirements. The primary function of the Service Port (Valve Assembly-Evaporative Emission Canister Purge Harness Service) is to provide non-destructive access to the evaporative emissions system to enable testing of the integrity of the system. The Service Port is used to introduce air pressure or fuel vapors into, or evacuates them out of, the system. This access may be used for the following evaluations: • Evaporative System Certifications Canister Loading and Purging • End-of-line Testing System Integrity • Service (e.g. OBD MIL on) Leak Location and Repair Verification • In-Use Compliance Testing Canister Loading and Purging • Inspection/Maintenance Testing System Integrity and Purge Check
Standard

Nonmetallic Fuel System Tubing with One or More Layers

2008-04-22
WIP
J2260
This SAE Standard presents the minimum requirements for nonmetallic tubing with one or more layers manufactured for use as liquid-carrying or vapor-carrying component in fuel systems for gasoline, or alcohol blends with gasoline. Requirements in this document also apply to monowall tubing (one layer construction). When the construction has one or more layers of polymer-based compounds in the wall, the multilayer constructions are primarily for the purpose of improvement in permeation resistance to hydrocarbons found in various fuels. The tube construction can have a straight-wall configuration, a wall that is convoluted or corrugated, or a combination of each. It may have an innermost layer with improved electrical conductivity for use where such a characteristic is desired. The improved electrical conductivity can apply to the entire wall construction, if the tubing is a monowall. (For elastomeric based MLT constructions, refer to SAE J30 and SAE J2405).
Standard

Test Procedure to Measure the Fuel Permeability of Materials by the Cup Weight Loss Method

2006-10-13
HISTORICAL
J2665_200610
This test standard covers the procedure for measuring the permeation of fuel or fuel surrogates through test samples of elastomeric, plastic or composite materials, up to about 3 mm thick. The method involves filling a test cup with the test fluid (fuel or fuel surrogate), sealing test sample over the open end of the cup, and then placing the sealed container into an oven at the desired test temperature and measuring the weight loss over time. Permeation rates are calculated from the rate of weight loss and the exposed area of the test sample. Standard permeation test temperatures are 40 °C and 60 °C. Standard test fluids are Fuel C, Fuel CE10 and Fuel CM15. Other fluids, such as Fuel CMTBE15, and other volatile liquids may be tested according to this procedure as desired (SAE J1681). The method is not applicable for measuring permeation of higher boiling materials that will not completely evaporate from the exterior surface of the sample at the test temperature.
Standard

Fuel Tank Filler Cap and Cap Retainer

2005-08-04
HISTORICAL
J829_200508
This SAE Standard was developed primarily for passenger car and truck applications for the sizes indicated, but it may be used in marine, industrial, and similar applications.
Standard

Rated (Advertised) Fuel Capacity—Passenger Car, Multi-Purpose Passenger Vehicles, and Light Duty Trucks

2005-03-24
HISTORICAL
J398_200503
This recommended practice provides a method for establishing the rated or advertised fuel capacity for a vehicle utilizing liquid fuel at atmospheric pressure. It applies to passenger cars, multi-purpose passenger vehicles and light duty trucks (10 000 lb (4536 kg) maximum GVW), (Ref. SAE J1100). It also includes a standardized procedure for creating a full tank when another test requires that condition as a starting point. It is intended as a guide toward standard practice and is subject to change to keep pace with experience and technical advances.
Standard

Fuel Tank Filler Cap and Cap Retainer

2000-06-16
HISTORICAL
J829_200006
This SAE Standard was developed primarily for passenger car and truck applications for the sizes indicated, but it may be used in marine, industrial, and similar applications.
Standard

Filler Pipes and Openings of Motor Vehicle Fuel Tanks

2000-04-04
HISTORICAL
J1140_200004
This SAE Recommended Practice was developed primarily for gasoline-powered passenger car and truck applications but may be used in marine, industrial, and similar applications where refueling vapor recovery is required.
Standard

Gasoline Dispenser Nozzle Spouts

1999-01-01
HISTORICAL
J285_199901
This SAE Recommended Practice provides standardized dimensions for nozzle spouts and a system for differentiating between "unleaded gasoline" nozzle spouts and all other fuel nozzle spouts. If emission control equipment requires unleaded gasoline exclusively and other fuels not meeting this specification are available, differentiation is accomplished by providing differences between the outside diameter of the nozzle spouts used to dispense "unleaded gasoline" and those used for all other fuels. These differences establish a basis on which fuel filler inlets that will accept only "unleaded gasoline" can be designed. Spouts used to dispense "unleaded gasoline" should have a nominal OD of 20.6 mm (13/16 in) and be straight for 85 to 95 mm (3.35 to 3.74 in) from the outlet. It is understood that tolerances and normal use may increase the spout up to 21.3 mm (0.84 in) OD. The spouts for all other fuels should have a nominal OD of 23.8 mm (15/16 in) or more.
Standard

FUEL TANK FILLER CONDITIONS—PASSENGER CAR, MULTIPURPOSE PASSENGER VEHICLES, AND LIGHT-DUTY TRUCKS

1995-07-01
HISTORICAL
J398_199507
This SAE Recommended Practice defines conditions for evaluating the compatibility of vehicle fuel tanks and filler pipes with fuel dispensing facilities equipped with standard (non-vapor recovery) configuration as well as vapor recovery type nozzles. It applies to passenger cars, multipurpose passenger vehicles, and light-duty trucks 4536 kg (10 000 lb) maximum GVW (Ref. J1100). It includes a technique for filling a tank full that can be used to establish a reference condition for other tests which require starting with a full tank.
Standard

FUEL TANK FILLER CONDITIONS - PASSENGER CAR, MULTI-PURPOSE PASSENGER VEHICLES, AND LIGHT DUTY TRUCKS

1988-02-01
HISTORICAL
J398_198802
This recommended practice defines conditions for evaluating the compatibility of vehicle fuel tanks and filler pipes with fuel dispensing facilities equipped with standard (non-vapor recovery) configuration as well as vapor recovery type nozzles. It applies to passenger cars, multi-purpose passenger vehicles, and light-duty trucks (10 000 lb (4536 kg) maximum gvw), (Ref. J1100, Motor Vehicle Dimensions). It includes a technique for filling a tank full that can be used to establish a reference condition for other tests which require starting with a full tank.
X