Refine Your Search

Search Results

Viewing 1 to 11 of 11
Journal Article

Experimental Investigation of Heat Transfer Rate and Pressure Drop through Angled Compact Heat Exchangers Relative to the Incoming Airflow

2014-09-30
2014-01-2337
This paper presents pressure drops and heat transfer rates for compact heat exchangers, where the heat exchangers are angled 90°, 60°, 30° and 10° relative to the incoming airflow. The investigation is based on three heat exchangers with thicknesses of 19mm and 52mm. Each heat exchanger was mounted in a duct, where it was tested for thermal and isothermal conditions. The inlet temperature of the coolant was defined to two temperatures; ambient temperature and 90°C. For the ambient cases the coolant had the same temperature as the surrounding air, these tests were performed for five airflow rates. When the coolant had a temperature of 90°C a combination of five coolant flow rates and five airflow rates were tested. The test set-up was defined as having a constant cross-section area for 90°, 60° and 30° angles, resulting in a larger core area and a lower airspeed through the core, for a more inclined heat exchanger.
Journal Article

Comparative Studies between CFD and Wind Tunnel Measurements of Cooling Performance and External Aerodynamics for a Heavy Truck

2014-09-30
2014-01-2443
Nowadays, much focus for vehicle manufacturers is directed towards improving the energy efficiency of their products. The aerodynamic drag constitutes one major part of the total driving resistance for a vehicle travelling at higher speeds. In fact, above approximately 80km/h the aerodynamic drag is the dominating resistance acting on a truck. Hence the importance of reducing this resistance is apparent. Cooling drag is one part of the total aerodynamic drag, which arises from air flowing through the heat exchangers, and the irregular under-hood area. When using Computational Fluid Dynamics (CFD) in the development process it is of great importance to ensure that the methods used are accurately capturing the physics of the flow. This paper deals with comparative studies between CFD and wind-tunnel tests. In this paper, two comparative studies are presented.
Journal Article

CFD Simulations of one Period of a Louvered Fin where the Airflow is Inclined Relative to the Heat Exchanger

2015-04-14
2015-01-1656
This article presents Computational Fluid Dynamics (CFD) simulations fo one period of a louvered fin, for a crossflow compact finned heat exchanger, where the incoming airflow was inclined relative to its core. Four inclinations were investigated: 90°, which was when the air flowed perpendicular to the heat exchanger, 60°, 30° and 10° angles relative to the vertical plane. The study included three heat exchanger designs, where two of them had symmetrical louvered fins and a thickness of 19mm and 52mm. The third had a thickness of 19mm and had the louvers angled in one direction. All heat exchangers have been simulated when the airflow entered both from above and below relative to the horizontal plane. Simulations have also been carried out when the airflow entered from the side, illustrating the heat exchanger to be angled relative to the vertical axis. Two air speeds have been investigated for each configuration, where the results were compared to experimental data.
Journal Article

Simulation of Energy Used for Vehicle Interior Climate

2015-12-01
2015-01-9116
In recent years fuel consumption of passenger vehicles has received increasing attention by customers, the automotive industry, regulatory agencies and academia. However, some areas which affect the fuel consumption have received relatively small interest. One of these areas is the total energy used for vehicle interior climate which can have a large effect on real-world fuel consumption. Although there are several methods described in the literature for analyzing fuel consumption for parts of the climate control system, especially the Air-Condition (AC) system, the total fuel consumption including the vehicle interior climate has often been ignored, both in complete vehicle testing and simulation. The purpose of this research was to develop a model that predicts the total energy use for the vehicle interior climate. To predict the total energy use the model included sub models of the passenger compartment, the air-handling unit, the AC, the engine cooling system and the engine.
Journal Article

Force Based Measurement Method for Cooling Flow Quantification

2017-03-28
2017-01-1520
Quantification of heat exchanger performance in its operative environment is in many engineering applications an essential task, and the air flow rate through the heat exchanger core is an important optimizing parameter. This paper explores an alternative method for quantifying the air flow rate through compact heat exchangers positioned in the underhood of a passenger car. Unlike conventional methods, typically relying on measurements of direct flow characteristics at discrete probe locations, the proposed method is based on the use of load-cells for direct measurement of the total force acting on the heat exchanger. The air flow rate is then calculated from the force measurement. A direct comparison with a conventional pressure based method is presented as both methods are applied on a passenger car’s radiator tested in a full scale wind tunnel using six different grill configurations. The measured air flow rates are presented and discussed over a wide range of test velocities.
Technical Paper

Continued Study of the Error and Consistency of Fan CFD MRF Models

2010-04-12
2010-01-0553
The most common fan model to use in commercial CFD software today is the Multiple Reference Frame (MRF) model. This is at least valid for automotive under hood applications. Within the industry, for this typical application, this model is commonly known to under predict performance. This under prediction has been documented by the authors' of this paper in SAE paper 2009-01-0178 and VTMS paper 2009-01-3067. Furthermore has this been documented by S.Moreau from Valeo in “Numerical and Experimental Investigation of Rotor-Stator Interaction in Automotive Engine Cooling Fan Systems”, ETC, 7th European Conference on Turbomachinery, 2007. In preceding papers a specific methodology of use has been documented and it has been shown that the MRF model under predicts performance for the airflow in a cooling system commonly with 14% in volumetric flow rate. This is for a system dominated by inertial effects.
Technical Paper

Cooling Performance Investigation of a Rear Mounted Cooling Package for Heavy Vehicles

2011-04-12
2011-01-0174
The aim of the study was to investigate the cooling performance of two cooling package positions for distribution vehicles by using Computational Fluid Dynamics. The first cooling package was positioned in the front of the vehicle, behind the grill and the second position was at the rear of the vehicle. Each case was evaluated by its cooling performance for a critical driving situation and its aerodynamic drag at 90 km/h, where the largest challenge of an alternative position is the cooling air availability. The geometry used was a semi-generic commercial vehicle, based on a medium size distribution truck with a heat rejection value set to a fixed typical level at maximum power for a 13 litre Euro 6 diesel engine. The heat exchangers included in the study were the air conditioning condenser, the charge air cooler and the radiator. It was found that the main problem with the rear mounted cooling installation was the combination of the fan and the geometry after the fan.
Technical Paper

Continuing Cooling Performance Investigation of a Rear Mounted Cooling Package for Heavy Vehicles

2011-09-13
2011-01-2285
This investigation is a continuing analysis of the cooling performance and aerodynamic properties of a rear-mounted cooling module on a semi-generic commercial vehicle, which was carried out by Larsson, Löfdahl and Wiklund. In the previous study two designs of the cooling package installation were positioned behind the rear wheelhouse and the results were compared to a front-mounted cooling module. The investigation was mainly focused on a critical cooling situation occurring at lower vehicle speeds for a local distribution vehicle. The conclusion from the study was that the cooling performance for one of the rear-mounted installation was favorable compared to the front-mounted cooling package. This was mainly due to the low vehicle speed, the high fan speed and to fewer obstacles around the cooling module resulting in a lower system restriction within the installation.
Technical Paper

Comparison of Working Fluids in Both Subcritical and Supercritical Rankine Cycles for Waste-Heat Recovery Systems in Heavy-Duty Vehicles

2012-04-16
2012-01-1200
In a modern internal combustion engine, most of the fuel energy is dissipated as heat, mainly in the form of hot exhaust gas. A high temperature is required to allow conversion of the engine-out emissions in the catalytic system, but the temperature is usually still high downstream of the exhaust gas aftertreatment system. One way to recover some of this residual heat is to implement a Rankine cycle, which is connected to the exhaust system via a heat exchanger. The relatively low weight increase due to the additional components does not cause a significant fuel penalty, particularly for heavy-duty vehicles. The efficiency of a waste-heat recovery system such as a Rankine cycle depends on the efficiencies of the individual components and the choice of a suitable working fluid for the given boundary conditions.
Technical Paper

Selecting an Expansion Machine for Vehicle Waste-Heat Recovery Systems Based on the Rankine Cycle

2013-04-08
2013-01-0552
An important objective in combustion engine research is to develop strategies for recovering waste heat and thereby increasing the efficiency of the propulsion system. Waste-heat recovery systems based on the Rankine cycle are the most efficient tools for recovering energy from the exhaust gas and the Exhaust Gas Recirculation (EGR) system. The properties of the working fluid and the expansion machine have significant effects on Rankine cycle efficiency. The expansion machine is particularly important because it is the interface at which recovered heat energy is ultimately converted into power. Parameters such as the pressure, temperature and mass-flow conditions in the cycle can be derived for a given waste-heat source and expressed as dimensionless numbers that can be used to determine whether displacement expanders or turbo expanders would be preferable under the circumstances considered.
Technical Paper

Ultra-High Fuel Pressure in GDI to Suppress Particulate Formation during Warming-Up and Load Transients

2023-04-11
2023-01-0239
This study investigates if particulates from a GDI engine can be significantly suppressed by use of ultra-high injection pressures under 2 different engine conditions known to be associated with high particulate numbers (PN): warm-up and transients. Experiments were carried out in a single-cylinder GDI engine equipped with an endoscope connected to a high-speed camera to enable combustion visualization. To mimic the warming-up, the coolant temperature was varied between 20 °C and 90 °C. A Diesel injector with modified nozzle was used and the injection pressures were varied between 400 and 1500 bar. The results revealed that increasing the fuel injection pressure decreased engine out HC and PN under warming-up conditions. However, the coolant water temperature was the most dominant factor affecting the emissions. For coolant temperature of 20 °C, the use of 1500 bar fuel injection pressure in comparison to lower fuel pressures resulted in significantly lower PN.
X