Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

Correlating Dynamic Pressure Signal Features to Diesel Particulate Filter Load

2007-04-16
2007-01-0333
The firing frequency components of the dynamic diesel particulate filter pressure signals carry significant information about the particulate load. Specifically, the normalized magnitude and relative phase of the firing frequency components exhibit clear dependence on the particulate load in a filter. Further, the test-to-test variation and back-to-back repeatability in this work was better for the dynamic pressure signal features than for the mean value pressure drop. This work provides a promising extension or alternative to the mean value pressure drop correlation to particulate load through Darcy's Law. The results may be particularly useful for filter monitoring and control.
Technical Paper

1-D Dynamic Diesel Particulate Filter Model for Unsteady Pulsating Flow

2007-04-16
2007-01-1140
A fast time-scale 1-D dynamic diesel particulate filter model capable of resolving the pressure pulsations due to individual cylinder firing events is presented. The purpose of this model is to investigate changes in the firing frequency component of the pulsating exhaust flow at different particulate loadings. Experimental validation data and simulation results clearly show that the magnitude and phase of the firing frequency components are directly correlated to the mass of particulate stored in a diesel particulate filter. This dynamic pressure signal information may prove particularly useful for monitoring particulate load during vehicle operation.
Technical Paper

Cylinder Deactivation for Increased Engine Efficiency and Aftertreatment Thermal Management in Diesel Engines

2018-04-03
2018-01-0384
Diesel engine cylinder deactivation (CDA) can be used to reduce petroleum consumption and greenhouse gas (GHG) emissions of the global freight transportation system. Heavy duty trucks require complex exhaust aftertreatment (A/T) in order to meet stringent emission regulations. Efficient reduction of engine-out emissions require a certain A/T system temperature range, which is achieved by thermal management via control of engine exhaust flow and temperature. Fuel efficient thermal management is a significant challenge, particularly during cold start, extended idle, urban driving, and vehicle operation in cold ambient conditions. CDA results in airflow reductions at low loads. Airflow reductions generally result in higher exhaust gas temperatures and lower exhaust flow rates, which are beneficial for maintaining already elevated component temperatures. Airflow reductions also reduce pumping work, which improves fuel efficiency.
Technical Paper

Finite Element Analysis of Soot Load Detection Capability via Electrical Capacitance Tomography in a Diesel Particulate Filter

2018-04-03
2018-01-0648
In this paper, feasibility study was completed to prove the ability of detecting soot load amount in diesel particulate filter using electromagnetic finite element model. It is critical to accurately measure the soot load in a Diesel Particulate Filter (DPF) in order to optimize the active regeneration process that clears the filter clogged with soot. Tetrahedral mesh was created with electrostatic solid element for this analysis. Because of the geometry of the DPF and the narrowness of some sections between holes, a very fine mesh was generated. A model consistency study was created illustrating the effect of clogging on the internal electric field of the filter. Multiple scenarios representing various clogging configurations were simulated. These configurations included a fully clogged filter, the top-right quadrant of holes clogged, and the lower half of holes clogged.
Technical Paper

Real-Time On-Board Indirect Light-Off Temperature Estimation as a Detection Technique of Diesel Oxidation Catalyst Effectiveness Level

2013-04-08
2013-01-1517
The latest US emission regulations require dramatic reductions in Nitrogen Oxide (NOx) emissions from vehicular diesel engines. Selective Catalytic Reduction (SCR) is the current technology that achieves NOx reductions of up to 90%. It is typically mounted downstream of the existing after-treatment system, i.e., after the Diesel Oxidation Catalyst (DOC) and Diesel Particulate Filter (DPF). Accurate prediction of input NO₂:NO ratio is useful for control of SCR urea injection to reduce NOx output and NH₃ slippage downstream of the SCR catalyst. Most oxidation of NO to NO₂ occurs in the DOC since its main function is to oxidize emission constituents. The DOC thus determines the NO₂:NO ratio as feedgas to the SCR catalyst. The prediction of NO₂:NO ratio varies as the catalyst in the DOC ages or deteriorates due to poisoning. Thus, the DOC prediction model has to take into account the correlation of DOC conversion effectiveness and the aging of the catalyst.
Technical Paper

Measuring Particulate Load in a Diesel Particulate Filter

2006-04-03
2006-01-0868
A gravimetric particulate measurement system, which extracts samples isokinetically from raw exhaust, is presented to quantify the particulate mass stored in diesel particulate filters. The purpose of this measurement system is to facilitate the study of wall-flow filter behavior at different particulate load levels. Within this paper, the design considerations for the particulate measurement system are detailed and its operation is described. The accuracy of the measurement is examined through a theoretical error analysis and direct experimental comparison to the differential weight of a diesel particulate filter. Experimental results are also presented to validate the ability of the system to maintain the isokinetic sampling condition.
X