Refine Your Search

Topic

Search Results

Journal Article

Start-Up Characteristics and Gravity Effects on a Medium/High-Lift Heat Pump using Advanced Hybrid Loop Technology

2008-06-29
2008-01-1959
Thermal characterization was performed on a vapor compression heat pump using a novel, hybrid two phase loop design. Previous work on this technology has demonstrated its ability to provide passive phase separation and flow control based on capillary action. This provides high quality vapor to the compressor without relying on gravity-based phase separation or other active devices. This paper describes the subsequent work done to characterize evaporator performance under various startup scenarios, tilt angles, and heat loads. The use of a thermal expansion valve as a method to regulate operation was investigated. The effect of past history of use on startup behavior was also studied. Testing under various tilt angles showed evaporator performance to be affected by both adverse and favorable tilts for the given compressor. And depending on the distribution of liquid in the system upon startup, markedly different performance can result for the same system settings and heat loads.
Journal Article

Off-Gassing and Particle Release by Heated Polymeric Materials

2008-06-29
2008-01-2090
Polymers are one of the major constituents in electrical components. A study investigating pre-combustion off-gassing and particle release by polymeric materials over a range of temperatures can provide an understanding of thermal degradation prior to failure which may result in a fire hazard. In this work, we report simultaneous measurements of pre-combustion vapor and particle release by heated polymeric materials. The polymer materials considered for the current study are silicone and Kapton. The polymer samples were heated over the range 20 to 400°C. Response to vapor releases were recorded using the JPL Electronic Nose (ENose) and Industrial Scientific's ITX gas monitor configured to detect hydrogen chloride (HCl), carbon monoxide (CO) and hydrogen cyanide (HCN). Particle release was monitored using a TSI P-TRAK particle counter.
Technical Paper

Development of the Surface Thermal Environment for the Mars Scout Phoenix Mission

2007-07-09
2007-01-3239
Phoenix is NASA's first Mars Scouts Mission that will place a soft-lander on the Martian surface at a high northern latitude. Much of the Mars surface environmental flight data from landed missions pertains to the near-equatorial regions. However, orbital observations have yielded very useful data about the surface environment. These data along with a simple, but highly effective one-dimensional atmospheric model was used to develop the Phoenix surface thermal environment. As candidate landing sites were identified, parametric studies including statistical variations were conducted to prescribe minimum nighttime and maximum daytime temperature design Sols (a Martian day). Atmospheric effects such as clouds and ice were considered. Finally, recent candidate landing site imaging conducted by the Mars Reconnaissance Orbiter revealed that the prime site contained a much higher rock density than first thought.
Technical Paper

Viral Populations within the International Space Station's Internal Active Thermal Control System Ground Support and Potential Flight Hardware

2007-07-09
2007-01-3108
The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) contains an aqueous, alkaline fluid (pH 9.5±0.5) that aids in maintaining a habitable environment for the crew. Because microbes have significant potential to cause disease, adverse effects on astronaut health, and microbe-induced corrosion, the presence of both bacteria and viruses within IATCS fluids is of concern. This study sought to detect and identify viral populations in IATCS samples obtained from the Kennedy Space Center as a first step towards characterizing and understanding potential risks associated with them. Samples were concentrated and viral nucleic acids (NA) extracted providing solutions containing 8.87-22.67 μg NA per mL of heat transfer fluid. After further amplification viral DNA and cDNA were then pooled, fluorescently labeled, and hybridized onto a Combimatrix panvira 12K microarray containing probes for ∼1,000 known human viruses.
Technical Paper

Thermal Vacuum Testing of the Orbiting Carbon Observatory Instrument

2008-06-29
2008-01-2036
The Orbiting Carbon Observatory (OCO) instrument is scheduled for launch onboard an Orbital Sciences Corporation LEOStar-2 architecture spacecraft in December 2008. The instrument will collect data to identify CO2 sources and sinks and quantify their seasonal variability. OCO observations will permit the collection of spatially resolved, high resolution spectroscopic observations of CO2 and O2 absorption in reflected sunlight over both continents and oceans. OCO has three bore-sighted, high resolution, grating spectrometers which share a common telescope with similar optics and electronics. A 0.765 μm channel will be used for O2 observations, while the weak and strong CO2 bands will be observed with 1.61 μm and 2.06 μm channels, respectively. The OCO spacecraft circular polar orbit will be sun-synchronous with an inclination of 98.2 degrees, mean altitude of 705 km and 98.9 minute orbit period.
Technical Paper

Operation of Third Generation JPL Electronic Nose on the International Space Station

2009-07-12
2009-01-2522
The Third Generation ENose is an air quality monitor designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 – 30 °C, relative humidity from 25 – 75% and pressure from 530 to 760 torr. This device was installed and activated on ISS on Dec. 9, 2008 and has been operating continuously since activation. Data are downlinked and analyzed weekly. Results of analysis of ENose monitoring data show the short term presence of low concentration of alcohols, octafluoropropane and formaldehyde as well as frequent short term unknown events.
Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Technical Paper

Planar Array REDOX Cells and pH Sensors for ISS Water Quality and Microbe Detection

2003-07-07
2003-01-2553
This paper describes results acquired from E-Tongue 2 and E-Tongue 3 which are arrays of planar three-element electrochemical cells and pH sensors. The approach uses ASV (Anodic Stripping Voltammery) to achieve a detection limit, which in the case of Pb, is below one μM which is needed for water quality measurements. The richness of the detectable species is illustrated with Fe where seven species are identified using the Pourbiax diagram. The detection of multiple species is illustrated using Pb and Cu. The apparatus was used to detect the electroactivity of the metabolic-surrogate, PMS (phenazine-methosulphate). Finally, four types of pH sensors were fabricated and characterized for linearity, sensitivity, and responsiveness.
Technical Paper

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

2002-07-15
2002-01-2503
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration.
Technical Paper

Expanding the Capabilities of the JPL Electronic Nose for an International Space Station Technology Demonstration

2006-07-17
2006-01-2179
An array-based sensing system based on polymer-carbon composite conductometric sensors is under development at JPL for use as an environmental monitor in the International Space Station. Sulfur dioxide has been added to the analyte set for this phase of development. Using molecular modeling techniques, the interaction energy between SO2 and polymer functional groups has been calculated, and polymers selected as potential SO2 sensors. Experiment has validated the model and two selected polymers have been shown to be promising materials for SO2 detection.
Technical Paper

Chemical Sensor Testing for Space Life Support Chemical Processing: Part I. Moisture Sensors

1994-06-01
941263
In support of the National Aeronautics and Space Administration(NASA), a laboratory has been established at the Jet Propulsion Laboratory (JPL) to evaluate the characteristics of chemical sensors which are candidates for use in a controlled chemical processing life support system. Such a facility is required for characterizing those sensors under development as well as those commercially available but whose functional properties are typically based upon operating in industrial environments that will not be completely synonomous with space operations. Space environments, such as an orbiting station or lunar base, will generally have different sensor requirements than terrestrial applications with respect to size, multifunctionality, sensitivity, reliability, temperature, ruggedness, mass, consumables, life, and power requirements. Both commercially available and developmental moisture sensors have been evaluated.
Technical Paper

Mars Exploration Rover Surface Mission Flight Thermal Performance

2005-07-11
2005-01-2827
NASA launched two rovers in June and July of 2003 as a part of the Mars Exploration Rover (MER) project. MER-A (Spirit) landed on Mars in Gusev Crater at 15 degrees South latitude and 175 degrees East longitude on January 4, 2004 (Squyres, et al., Dec. 2004). MER-B (Opportunity) landed on Mars in Terra Meridiani at 2 degrees South latitude and 354 degrees East longitude on January 25, 2004 (Squyres, et al., Aug. 2004). Both rovers have well exceeded their design lifetime (90 Sols) by more than a factor of 5. Spirit and Opportunity are still healthy and continue to execute their roving science missions at the time of this writing. This paper discusses rover flight thermal performance during the surface missions of both vehicles, covering roughly the time from the MER-A landing in late Southern Summer (aereocentric longitude, Ls = 328, Sol 1A) through the Southern Winter solstice (Ls = 90, Sol 255A) to nearly Southern Vernal equinox (Ls = 160, Sol 398A).
Technical Paper

Q-PCR Based Bioburden Assessment of Drinking Water Throughout Treatment and Delivery to the International Space Station

2005-07-11
2005-01-2932
Previous studies indicated evidence of opportunistic pathogens in samples obtained during missions to the International Space Station (ISS). This study utilized TaqMan quantitative PCR to determine specific gene abundance in potable and non-potable ISS waters. Probe and primer sets specific to the small subunit rRNA genes were designed and used to elucidate overall bacterial rRNA gene numbers. In addition, primer-probe sets specific for Burkholderia cepacia and Stenotrophomonas maltophilia were optimized and genes of these two opportunistic pathogens quantified in the pre- and post-flight drinking water as well as coolant waters. This Q-PCR approach supports findings of previous culture-based studies however; the culture based studies may have underestimated the microbial burden of ISS drinking water.
Technical Paper

Implications of the VBNC State of B. cepacia and S. maltophilia on Bioreduction and Microbial Monitoring of ISS Potable Waters

2005-07-11
2005-01-2933
Certain Eubacteria enter a viable but nonculturable (VBNC) state upon encountering unfavorable environmental conditions. VBNC cells do not divide on conventional media yet remain viable and in some cases retain virulence. Here, we describe the VBNC state of two opportunistic pathogens previously isolated from ISS potable waters, Burkholderia cepacia and Stenotrophomonas maltophilia. Artificially inoculated microcosms were exposed to the biocidal agents copper (CuSO4) and iodine (I2) in an attempt to induce nonculturablility. Viability was assessed via fluorescent microscopy (direct viable count assay coupled with BacLight™ staining) and metabolic activity was monitored by quantifying both intracellular ATP and transcribed rRNA (reverse transcriptase quantitative PCR). Culturablility was lost in both B. cepacia and S. maltophilia within two days of exposure to copper or high concentrations of iodine (6 or 8 ppm).
Technical Paper

Mars Exploration Rover Thermal Test Program Overview

2004-07-19
2004-01-2310
In January 2004, two Mars Exploration Rovers (MER) landed on the surface of Mars to begin their mission as robotic geologists. A year prior to these historic landings, both rovers and the spacecraft that delivered them to Mars, were completing a series of environmental tests in facilities at the Jet Propulsion Laboratory. This paper describes the test program undertaken to validate the thermal design and verify the workmanship integrity of both rovers and the spacecraft. The spacecraft, which contained the rover within the aeroshell, were tested in a 7.5 m diameter thermal vacuum chamber. Thermal balance was performed for the near earth (hot case) condition and for the near Mars (cold case) condition. A solar simulator was used to provide the solar boundary condition on the solar array. IR lamps were used to simulate the solar heat load on the aeroshell for the off-sun attitudes experienced by the spacecraft during its cruise to Mars.
Technical Paper

Physical and Environmental Effects on the Energy Dissipating Characteristics of Balsa Wood

1966-02-01
660657
This paper presents the results of a developmental program designed to determine physical and environmental effects on the response of balsa wood as an energy dissipator. Specifically, the effects of moisture content, density, temperature, and pressure on the energy dissipating characteristics of balsa wood are presented. It is shown that the response of balsa wood is critically dependent on physical and environmental conditions, and that the energy dissipating capacity of the material increases significantly under certain combinations of these conditions.
Technical Paper

Self-Sterilizing Properties of Martian Soil: Possible Nature & Implications

2000-07-10
2000-01-2343
As a result of the Viking missions in 1970s, the presence of a strong oxidant in Martian soil was suggested. Here we present a testable, by near-term missions, hypothesis that iron(VI) contributes to that oxidizing pool. Ferrate(VI) salts were studied for their spectral and oxidative properties and biological activities. Ferrate(VI) has distinctive spectroscopic features making it available for detection by remote sensing reflectance spectra and contact measurements via Mössbauer spectroscopy. The relevant miniaturized instrumentation has been developed or is underway, while XANES spectroscopy is shown to be a method of choice for the returned samples. Ferrate(VI) is capable of splitting water to yield oxygen, and oxidizing organic carbon to CO2. Organic oxidation was strongly abated after pre-heating ferrate, similar to the observations with Mars soil samples.
Technical Paper

Operation of an Electronic Nose Aboard the Space Shuttle and Directions for Research for a Second Generation Device

2000-07-10
2000-01-2512
A flight experiment to test the operation of an Electronic Nose developed and built at JPL and Caltech was done aboard STS-95 in October-November, 1998. This ENose uses conductometric sensors made of insulating polymer-carbon composite films; it has a volume of 1.7 liters, weighs 1.4 kg including the operating computer and operates on 1.5 W average power. In the flight experiment, the ENose was operated continuously for 6 days and recorded the sensors' response to changes in air in the mid-deck of the orbiter. The ENose had been trained to identify and quantify ten common contaminants at the 24-hour Spacecraft Maximum Allowable Concentration (SMAC) level. Most SMACs are on the order of 10-100 ppm. The experiment was controlled by collecting air samples daily and analyzing them using standard analytical techniques after the flight. The device is microgravity insensitive.
Technical Paper

Validation of the SCARLET Advanced Array on DS1

1999-08-02
1999-01-2630
In October, 1998, the first of the NASA New Millennium Spacecraft, DS1, was successfully launched into space. The objectives for this spacecraft are to test advanced technologies that can reduce the cost or risk of future missions. One of these technologies is the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET). Although part of the advanced technology validation study, the array is also the spacecraft power source. Funded by BMDO, the SCARLET™ concentrator solar array is the first spaceflight application of a refractive lens concentrator. As part of the DS1 validation process, the amount of array diagnostics is very extensive. The data obtained includes temperature measurements at numerous locations on the 2-wing solar array. For each individual panel, a 5-cell module in one of the circuit strings is wired so that a complete I-V curve can be obtained. This data is used to verify sun pointing accuracy and array output performance.
Technical Paper

Slow Reversible and Quasi-Reversible Performance Changes in AMTEC Electrodes and Electrolytes

1999-08-02
1999-01-2705
This paper reports several slow reversible and quasi-reversible processes which occur in the porous electrode/solid electrolyte combination at AMTEC operating temperatures. These processes help to elucidate the evolution of the electrode and electrolyte characteristics with time. They also demonstrate that the atomic constituents of the electrode/electrolyte engage in significant dynamic motion. We report the stability of the sodium beta“-alumina phase in low pressure sodium vapor at 1173K up to 3000 hours, and the decomposition of the sodium meta-aluminate (NaAlO2) phase present at about 1% in the BASE ceramic, which gives rise to transient local increases in the solid electrolyte resistivity due to local micro-cracking. We also report slow apparent morphological changes, possibly surface or grain boundary reconstruction, in TiN and RhW electrodes driven by changes in the local sodium activity.
X