Refine Your Search

Topic

Search Results

Viewing 1 to 11 of 11
Journal Article

Hydrocarbons and Particulate Matter in EGR Cooler Deposits: Effects of Gas Flow Rate, Coolant Temperature, and Oxidation Catalyst

2008-10-06
2008-01-2467
Compact heat exchangers are commonly used in diesel engines to reduce the temperature of recirculated exhaust gases, resulting in decreased NOx emissions. These exhaust gas recirculation (EGR) coolers experience fouling through deposition of particulate matter (PM) and hydrocarbons (HCs) that reduces the effectiveness of the cooler. Surrogate tubes have been used to investigate the impacts of gas flow rate and coolant temperature on the deposition of PM and HCs. The results indicate that mass deposition is lowest at high flow rates and high coolant temperatures. An oxidation catalyst was investigated and proved to effectively reduce deposition of HCs, but did not reduce overall mass deposition to near-zero levels. Speciation of the deposit HCs showed that a range of HCs from C15 - C25 were deposited and retained in the surrogate tubes.
Technical Paper

Influence of Tensioner Friction on Accessory Drive Dynamics

1997-05-20
971962
Belt drives have long been utilized in engine applications to power accessories such as alternators, pumps, compressors and fans. The first belt drives consisted of one or more V-belts powering fixed-centered pulleys and were pre-tensioned by statically adjusting the pulley center separation distances. In recent years, such drives have been replaced by a single, flat, ‘serpentine belt’ tensioned by an ‘automatic tensioner.’ The automatic tensioner consists of a spring-loaded, dry friction damped, tensioner arm that contacts the belt through an idler pulley. The tensioner's major function is to maintain constant belt tension in the presence of changing engine speeds and accessory loads. The engine crankshaft supplies both the requisite power to drive the accessories as well as the (unwanted) dynamic excitation that can adversely affect the accessories and the noise and vibration performance of the belt.
Technical Paper

Characterization of the Fluid Deaeration Device for a Hydraulic Hybrid Vehicle System

2008-04-14
2008-01-0308
The attractiveness of the hydraulic hybrid concept stems from the high power density and efficiency of the pump/motors and the accumulator. This is particularly advantageous in applications to heavy vehicles, as high mass translates into high rates of energy flows through the system. Using dry case hydraulic pumps further improves the energy conversion in the system, as they have 1-4% better efficiency than traditional wet-case pumps. However, evacuation of fluid from the case introduces air bubbles and it becomes imperative to address the deaeration problems. This research develops a bubble elimination efficiency testing apparatus (BEETA) to establish quantitative results characterizing bubble removal from hydraulic fluid in a cyclone deaeration device. The BEETA system mixes the oil and air according to predetermined ratio, passes the mixture through a cyclone deaeration device, and then measures the concentration of air in the exiting fluid.
Technical Paper

Power-By-Wire Piezoelectric-Hydraulic Pump Actuator for Automotive Transmission Shift Control

2009-04-20
2009-01-0950
In this study, a new actuation system concept is developed for automotive transmission shift control. A piezoelectric-hydraulic pump (in short, PHP) based actuation system is one of the potential alternatives that can replace the current electro-hydraulic actuation system in automotive transmissions. Their feasibility has been successfully demonstrated in a lab environment. This study extends the application of the PHP actuator into an AT (Automatic Transmission) test-bed to validate the effectiveness of the new power-by-wire actuation concept. To demonstrate the potentials of the PHP actuator, a nonlinear sliding mode control for force tracking and hardware-in-the-loop simulation (in short, HILS) are performed.
Technical Paper

Experimental Studies of EGR Cooler Fouling on a GDI Engine

2016-04-05
2016-01-1090
Cooled EGR provides benefits in better fuel economy and lower emissions by reducing knocking tendency and decreasing peak cylinder temperature in gasoline engines. However, GDI engines have high particle emissions due to limited mixing of fuel and air, and these particle emissions can be a major source of EGR cooler fouling. In order to improve our knowledge of GDI engine EGR cooler fouling, the effects of tube geometry and coolant temperature on EGR cooler performance and degradation were studied using a four cylinder 2.0L turbocharged GDI engine. In addition, deposit microstructure was analyzed to explore the nature of deposits formed under GDI engine operation. The results of this study showed that a dented tube geometry was more effective in cooling the exhaust gas than a smooth tube due to its large surface area and turbulent fluid motion. However, more deposits were accumulated and higher effectiveness loss was observed in the dented tube.
Technical Paper

Piston Heat Transfer Measurements Under Varying Knock Intensity in a Spark-Ignition Engine

1997-05-01
971667
Piston heat transfer measurements were taken under varying knock intensity in a modern spark-ignition engine combustion chamber. For a range of knocking spark timings, two knock intensity levels were obtained by using a high (80°C) and a low (50°C) cylinder head coolant temperature. Data were taken with a central and a side spark plug configuration. When the spark-plug was placed at the center of the combustion chamber, a linear variation of peak heat flux with knock intensity was found in the end-gas region. Very large changes in peak heat flux (on the order of 100%) occurred at probes whose relative location with respect to the end gas zone changed from being within (80°C coolant case) to being outside the zone (50°C coolant case). With side spark-plug, distinct differences in peak heat flux occurred at all probes and under all knock intensities, but the correlation between knock intensity and heat flux was not linear.
Technical Paper

Analysis and Control of Transient Flow in the Diesel Injection System Part II - Design Results of Controlled After-Injection

1973-02-01
730662
After-injection is the introduction of additional fuel to the combustion chamber after the end of the main injection. It is a persistent diesel fuel injection problem which usually results in reduced engine power and economy and increased emissions. After-injection is caused by uncontrolled pressure transients at the injector after the opening of the pump spill port. These pressure transients are related to the wave propagation phenomena in the high-pressure pipeline connecting the pump and injector. Use of experimental trial-and-error methods in attempts to control this phenomenon has met with limited success. The analytical control method described in another paper is used to determine design means by which after-injection may be controlled. Further investigation and evaluation of two design changes which release the injection system excess elastic energy in a controlled manner are considered herein. One design change is the addition of a control valve in the pump delivery chamber.
Technical Paper

Analysis and Control of Transient Flow in the Diesel Injection System Part I - The Analytical Control Method

1973-02-01
730661
The increasing requirements imposed on diesel engine manufacturers have required the study of fuel injection system faults and the development of means to eliminate them. Until now, improved injection system characteristics have been obtained by experimental trial-and-error procedures. These procedures, however, have proved to be inconvenient, tedious, and have had limited success in eliminating system faults such as after-injection. This is mainly because the transient nature of the injection process requires a more thorough study of the system time-varying parameters. In this paper the residual transients which cause after-injection are analytically investigated. The control of these transients required specification of some system parameter. The rapidly varying nature of the system pressures and flows prevented the use of these variables as control parameters.
Technical Paper

A Hybrid Electric Vehicle Thermal Management System - Nonlinear Controller Design

2015-04-14
2015-01-1710
The components in a hybrid electric vehicle (HEV) powertrain include the battery pack, an internal combustion engine, and the electric machines such as motors and possibly a generator. These components generate a considerable amount of heat during driving cycles. A robust thermal management system with advanced controller, designed for temperature tracking, is required for vehicle safety and energy efficiency. In this study, a hybridized mid-size truck for military application is investigated. The paper examines the integration of advanced control algorithms to the cooling system featuring an electric-mechanical compressor, coolant pump and radiator fans. Mathematical models are developed to numerically describe the thermal behavior of these powertrain elements. A series of controllers are designed to effectively manage the battery pack, electric motors, and the internal combustion engine temperatures.
Technical Paper

The Effect of Exhaust Emission Conditions and Coolant Temperature on the Composition of Exhaust Gas Recirculation Cooler Deposits

2023-04-11
2023-01-0438
Exhaust Gas Recirculation (EGR) coolers are widely used on diesel engines to reduce in-cylinder NOx formation. A common problem is the accumulation of a fouling layer inside the heat exchanger, mainly due to thermophoresis that leads to deposition of particulate matter (PM), and condensation of hydrocarbons (HC) from the diesel exhaust. From a recent investigation of deposits from field samples of EGR coolers, it was confirmed that the densities of their deposits were much higher than reported in previous studies. In this study, the experiments were conducted in order to verify hypotheses about deposit growth, especially densification. An experimental set up which included a custom-made shell and tube type heat exchanger with six surrogate tubes was designed to control flow rate independently, and was installed on a 1.9 L L-4 common rail turbo diesel engine.
Technical Paper

An In-Cylinder Imaging Study of Pre-chamber Spark-Plug Flame Development in a Single-Cylinder Direct-Injection Spark-Ignition Engine

2023-04-11
2023-01-0254
Prior work in the literature have shown that pre-chamber spark plug technologies can provide remarkable improvements in engine performance. In this work, three passively fueled pre-chamber spark plugs with different pre-chamber geometries were investigated using in-cylinder high-speed imaging of spectral emission in the visible wavelength region in a single-cylinder direct-injection spark-ignition gasoline engine. The effects of the pre-chamber spark plugs on flame development were analyzed by comparing the flame progress between the pre-chamber spark plugs and with the results from a conventional spark plug. The engine was operated at fixed conditions (relevant to federal test procedures) with a constant speed of 1500 revolutions per minute with a coolant temperature of 90 oC and stoichiometric fuel-to-air ratio. The in-cylinder images were captured with a color high-speed camera through an optical insert in the piston crown.