Refine Your Search

Author

Search Results

Viewing 1 to 16 of 16
Journal Article

Biomechanical Response of the Human Face and Corresponding Biofidelity of the FOCUS Headform

2010-04-12
2010-01-1317
In order to evaluate a human surrogate, the human and surrogate response must be defined. The purpose of this study was to evaluate the response of cadaver subjects to blunt impacts to the frontal bone, nasal bone and maxilla. Force-displacement corridors were developed based on the impact response of each region. Variation in the force-displacement response of the cadaver subjects due to the occurrence of fracture and fracture severity was demonstrated. Additionally, impacts were performed at matched locations using the Facial and Ocular CountermeasUre Safety (FOCUS) headform. The FOCUS headform is capable of measuring forces imposed onto facial structures using internal load cells. Based on the tests performed in this study, the nasal region of the FOCUS headform was found to be the most sensitive to impact location. Due to a wide range in geometrical characteristics, the nasal impact response varied significantly, resulting in wide corridors for human response.
Technical Paper

A Multi-Body Computational Study of the Kinematic and Injury Response of a Pedestrian with Variable Stance upon Impact with a Vehicle

2004-03-08
2004-01-1607
This research investigates the variation of pedestrian stance in pedestrian-automobile impact using a validated multi-body vehicle and human model. Detailed vehicle models of a small family car and a sport utility vehicle (SUV) are developed and validated for impact with a 50th percentile human male anthropometric ellipsoid model, and different pedestrian stances (struck limb forward, feet together, and struck limb backward) are investigated. The models calculate the physical trajectory of the multi-body models including head and torso accelerations, as well as pelvic force loads. This study shows that lower limb orientation during a pedestrian-automobile impact plays a dominant role in upper body kinematics of the pedestrian. Specifically, stance has a substantial effect on the subsequent impacts of the head and thorax with the vehicle. The variation in stance can change the severity of an injury incurred during an impact by changing the impact region.
Technical Paper

Comparative Evaluation of Dummy Response with Thor-Lx/HIIIr and Hybrid III Lower Extremities

2002-03-04
2002-01-0016
Multiple series of frontal sled tests were performed to evaluate the new Thor-Lx/HIIIr lower extremity developed by the National Highway Traffic Safety Administration for retrofit use on the 50th percentile male Hybrid III. This study's objective was to compare the Thor-Lx/HIIIr to the existing Hybrid III dummy leg (HIII) from the standpoint of repeatability and effects on femur and upper body response values.\ The test-to-test repeatability of the dummy responses, as measured by the coefficient of variation (CV), was generally acceptable (CV < 10%) for all of the test conditions for both legs. Overall, tests with the Thor-Lx/HIIIr legs produced upper body movement and injury criteria values for the head and chest that were acceptably consistent and were generally indistinguishable from those produced with the HIII leg. Low right femur loads, which ranged from 4 to 25 percent of the injury assessment reference value, varied substantially test-to-test for tests with both types of legs.
Technical Paper

Comprehensive Computational Rollover Sensitivity Study Part 2: Influence of Vehicle, Crash, and Occupant Parameters on Head, Neck, and Thorax Response

2011-04-12
2011-01-1115
Fatalities resulting from vehicle rollover events account for over one-third of all U.S. motor vehicle occupant fatalities. While a great deal of research has been directed towards the rollover problem, few studies have attempted to determine the sensitivity of occupant injury risk to variations in the vehicle (roof strength), crash (kinematic conditions at roof-to-ground contact), and occupant (anthropometry, position and posture) parameters that define the conditions of the crash. A two-part computational study was developed to examine the sensitivity of injury risk to changes in these parameters. The first part of this study, the Crash Parameter Sensitivity Study (CPSS), demonstrated the influence of parameters describing the vehicle and the crash on vehicle response using LS-DYNA finite element (FE) simulations.
Technical Paper

Development and Validation of an Occupant Lower Limb Finite Element Model

2011-04-12
2011-01-1128
More than half of occupant lower extremity (LEX) injuries due to automotive frontal crashes are in the knee-thigh-hip (KTH) complex. To design the injury countermeasures for the occupant LEX, first the biomechanical and injury responses of the occupant LEX components during automotive frontal crashes should be known. The objective of this study is to develop a detailed biofidelic occupant LEX Finite Element (FE) model based on the component surfaces reconstructed from the medical image data of a 50th percentile male volunteer in a sitting posture. Both volumetric (unstructured) and structural mesh methods were used to generate the solid elements (mostly hexahedral type) to enhance the model simulation accuracy. The FE model includes the femur, tibia, fibula, patella, cartilage, ligaments, menisci, patella tendon, flesh, muscle, and skin. The constitutive material models and their corresponding parameters were defined based on literature data.
Technical Paper

A Simulation-Based Calibration and Sensitivity Analysis of a Finite Element Model of THOR Head-Neck Complex

2011-04-12
2011-01-1123
The THOR-NT dummy has been developed and continuously improved by NHTSA to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. With the recent improvements of finite element (FE) technology and the increase of computational power, a validated FE model of THOR may provide an efficient tool for the design optimization of vehicles and their restraint systems. The main goal of this study was to improve biofidelity of a head-neck FE model of THOR-NT dummy. A three-dimensional FE model of the head and neck was developed in LS-Dyna based on the drawings of the THOR dummy. The material properties of deformable parts and the joints properties between rigid parts were assigned initially based on data found in the literature, and then calibrated using optimization techniques.
Technical Paper

Influence of Vehicle Body Type on Pedestrian Injury Distribution

2005-04-11
2005-01-1876
Pedestrian impact protection has been a growing area of research over the past twenty or more years. The results from many studies have shown the importance of providing protection to vulnerable road users as a means of reducing roadway fatalities. Most of this research has focused on the vehicle fleet as a whole in datasets that are dominated by passenger cars (cars). Historically, the influence of vehicle body type on injury distribution patterns for pedestrians has not been a primary research focus. In this study we used the Pedestrian Crash Data Study (PCDS) database of detailed pedestrian crash investigations to identify how injury patterns differ for pedestrians struck by light trucks, vans, and sport utility vehicles (LTVs) from those struck by cars. AIS 2+ and 3+ injuries for each segment of vehicles were mapped back to both the body region of the pedestrian injured and the vehicle source linked to that injury in the PCDS database.
Technical Paper

Neck Validation of Multibody Human Model under Frontal and Lateral Impacts using an Optimization Technique

2015-04-14
2015-01-1469
Multibody human models are widely used to investigate responses of human during an automotive crash. This study aimed to validate a commercially available multibody human body model against response corridors from volunteer tests conducted by Naval BioDynamics Laboratory (NBDL). The neck model consisted of seven vertebral bodies, and two adjacent bodies were connected by three orthogonal linear springs and dampers and three orthogonal rotational springs and dampers. The stiffness and damping characteristics were scaled up or down to improve the biofidelity of the neck model against NBDL volunteer test data because those characteristics were encrypted due to confidentiality. First, sensitivity analysis was performed to find influential scaling factors among the entire set using a design of experiment.
Technical Paper

Occupant Kinematics in Laboratory Rollover Tests: ATD Response and Biofidelity

2014-11-10
2014-22-0012
Rollover crashes are a serious public health problem in United States, with one third of traffic fatalities occurring in crashes where rollover occurred. While it has been shown that occupant kinematics affect the injury risk in rollover crashes, no anthropomorphic test device (ATD) has yet demonstrated kinematic biofidelity in rollover crashes. Therefore, the primary goal of this study was to assess the kinematic response biofidelity of six ATDs (Hybrid III, Hybrid III Pedestrian, Hybrid III with Pedestrian Pelvis, WorldSID, Polar II and THOR) by comparing them to post mortem human surrogate (PMHS) kinematic response targets published concurrently; and the secondary goal was to evaluate and compare the kinematic response differences among these ATDs.
Technical Paper

Investigation of Traumatic Brain Injuries Using the Next Generation of Simulated Injury Monitor (SIMon) Finite Element Head Model

2008-11-03
2008-22-0001
The objective of this study was to investigate potential for traumatic brain injuries (TBI) using a newly developed, geometrically detailed, finite element head model (FEHM) within the concept of a simulated injury monitor (SIMon). The new FEHM is comprised of several parts: cerebrum, cerebellum, falx, tentorium, combined pia-arachnoid complex (PAC) with cerebro-spinal fluid (CSF), ventricles, brainstem, and parasagittal blood vessels. The model's topology was derived from human computer tomography (CT) scans and then uniformly scaled such that the mass of the brain represents the mass of a 50th percentile male's brain (1.5 kg) with the total head mass of 4.5 kg. The topology of the model was then compared to the preliminary data on the average topology derived from Procrustes shape analysis of 59 individuals. Material properties of the various parts were assigned based on the latest experimental data.
Technical Paper

Whole-body Response for Pedestrian Impact with a Generic Sedan Buck

2015-11-09
2015-22-0016
To serve as tools for assessing injury risk, the biofidelity of whole-body pedestrian impact dummies should be validated against reference data from full-scale pedestrian impact tests. To facilitate such evaluations, a simplified generic vehicle-buck has been recently developed that is designed to have characteristics representative of a generic small sedan. Three 40 km/h pedestrian-impact tests have been performed, wherein Post Mortem Human Surrogates (PMHS) were struck laterally in a mid-gait stance by the buck. Corridors for select trajectory measures derived from these tests have been published previously. The goal of this study is to act as a companion dataset to that study, describing the head velocities, body region accelerations (head, spine, pelvis, lower extremities), angular velocities, and buck interaction forces, and injuries observed during those tests.
Technical Paper

Occupant Kinematics and Shoulder Belt Retention in Far-Side Lateral and Oblique Collisions: A Parametric Study

2013-11-11
2013-22-0014
In far-side impacts, head contact with interior components is a key injury mechanism. Restraint characteristics have a pronounced influence on head motion and injury risk. This study performed a parametric examination of restraint, positioning, and collision factors affecting shoulder belt retention and occupant kinematics in far-side lateral and oblique sled tests with post mortem human subjects (PMHS). Seven PMHS were subjected to repeated tests varying the D-ring position, arm position, pelvis restraint, pre-tensioning, and impact severity. Each PMHS was subjected to four low-severity tests (6.6 g sled acceleration pulse) in which the restraint or position parameters were varied and then a single higher-severity test (14 g) with a chosen restraint configuration (total of 36 tests). Three PMHS were tested in a purely lateral (90° from frontal) impact direction; 4 were tested in an oblique impact (60° from frontal). All subjects were restrained by a 3-point seatbelt.
Journal Article

Improving Earpiece Accelerometer Coupling to the Head

2008-12-02
2008-01-2978
As accurate measuring of head accelerations is an important aspect in predicting head injury, it is important that the measuring sensor be well-coupled to the head. Various sensors and sensor mounting schemes have been attempted in the past with varying results. This study uses a small, implantable acceleration sensor pack in the ear to study impact coupling with the human skull. The output from these ear-mounted accelerometers is compared to laboratory reference accelerometers rigidly attached to the skull of two cadaveric head specimens for both low-amplitude oscillatory tests and high-amplitude impact drop tests. The combination of sensor type and mounting scheme demonstrates the feasibility of using ear mounted sensors to predict head acceleration response. Previously reported progressive phase lag was not seen in this study, with the comparison between ear mounted accelerometers and rigidly mounted head accelerometers ranging from very good to excellent.
Technical Paper

Whole-Body Response to Pure Lateral Impact

2010-11-03
2010-22-0014
The objective of the current study was to provide a comprehensive characterization of human biomechanical response to whole-body, lateral impact. Three approximately 50th-percentile adult male PMHS were subjected to right-side pure lateral impacts at 4.3 ± 0.1 m/s using a rigid wall mounted to a rail-mounted sled. Each subject was positioned on a rigid seat and held stationary by a system of tethers until immediately prior to being impacted by the moving wall with 100 mm pelvic offset. Displacement data were obtained using an optoelectronic stereophotogrammetric system that was used to track the 3D motions of the impacting wall sled; seat sled, and reflective targets secured to the head, spine, extremities, ribcage, and shoulder complex of each subject. Kinematic data were also recorded using 3-axis accelerometer cubes secured to the head, pelvis, and spine at the levels of T1, T6, T11, and L3. Chest deformation in the transverse plane was recorded using a single chestband.
Technical Paper

Comparison of Kinematic Responses of the Head and Spine for Children and Adults in Low-Speed Frontal Sled Tests

2009-11-02
2009-22-0012
Previous research has suggested that the pediatric ATD spine, developed from scaling the adult ATD spine, may not adequately represent a child's spine and thus may lead to important differences in the ATD head trajectory relative to a human. To gain further insight into this issue, the objectives of this study were, through non-injurious frontal sled tests on human volunteers, to 1) quantify the kinematic responses of the restrained child's head and spine and 2) compare pediatric kinematic responses to those of the adult. Low-speed frontal sled tests were conducted using male human volunteers (20 subjects: 6-14 years old, 10 subjects: 18-40 years old), in which the safety envelope was defined from an amusement park bumper-car impact.
Journal Article

Occupant Kinematics and Injury Response in Steer Maneuver-Induced Furrow Tripped Rollover Testing

2015-04-14
2015-01-1478
Occupant kinematics during rollover motor vehicle collisions have been investigated over the past thirty years utilizing Anthropomorphic Test Devices (ATDs) in various test methodologies such as dolly rollover tests, CRIS testing, spin-fixture testing, and ramp-induced rollovers. Recent testing has utilized steer maneuver-induced furrow tripped rollovers to gain further understanding of vehicle kinematics, including the vehicle's pre-trip motion. The current study consisted of two rollover tests utilizing instrumented test vehicles and instrumented ATDs to investigate occupant kinematics and injury response throughout the entire rollover sequences, from pre-trip vehicle motion to the position of rest. The two steer maneuver-induced furrow tripped rollover tests utilized a mid-sized 4-door sedan and a full-sized crew-cab pickup truck. The pickup truck was equipped with seatbelt pretensioners and rollover-activated side curtain airbags (RSCAs).
X