Refine Your Search

Topic

Search Results

Standard

Cockpit Crew Oxygen Equipment for use from 35,000 ft to 45,000 ft altitude

2007-03-26
WIP
AS5722
This Aerospace Standard will provide the basis for a certification approach and contain the methods or criteria for verification of performance required of Personal Oxygen Dispensing Units for use by Cockpit Crew Members in the range of 35,000 to 45,000 ft cabin altitude.
Standard

Oxygen Equipment for Aircraft

1999-05-01
HISTORICAL
AIR825C
This report provides information on the design and use of aircraft oxygen systems. It explains the physiological oxygen requirements of the human body in both a normal environment and in an hypoxic environment. It includes an overview of the continuous flow, demand and pressure demand, and liquid oxygen systems. A basic understanding of how each system operates is then specifically addressed in its own titled section. The charts, tables, and schematics provide a specific example of a theoretical oxygen system design and the calculations showing how that system would meet the regulations established by the FAR’s. A comprehensive overview of the theoretical oxygen requirements of the human body at altitude is also provided. A detailed list of specifications and standards applicable to aircraft oxygen systems is included.
Standard

Dynamic Testing Systems for Oxygen Breathing Equipment

1997-09-01
CURRENT
ARP1109B
This SAE Aerospace Recommended Practice (ARP) recommends performance requirements for test equipment used in dynamic testing of aviation oxygen breathing equipment. This document describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.
Standard

DYNAMIC TESTING SYSTEMS FOR OXYGEN BREATHING EQUIPMENT

1987-04-01
HISTORICAL
ARP1109A
This ARP describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.
Standard

Carry-On Portable Oxygen Concentrators

2012-06-06
CURRENT
AS8059
This SAE Aerospace Standard (AS) applies to a personal, portable oxygen concentrator (POC) to be supplied and used by a passenger requiring supplemental oxygen therapy while traveling on board civil, commercial, or personal aircraft. It covers a POC during both self-powered battery operation and while powered from an aircraft seat’s electrical power through the use of an accessory adapter. The POC is not intended to be connected to the aircraft’s oxygen systems or to be used by any aircraft personnel in any method of treatment or first aid of the general flying public.
Standard

Chemical Oxygen Supplies

1991-04-15
HISTORICAL
AIR1133A
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

FAR – Regulatory Requirements Covering the Use of Breathing Oxygen in Aircraft

2016-06-22
CURRENT
AIR1389B
This report presents, paraphrased in tabular format, an overview of the Federal Aviation Regulations (FAR) for aircraft oxygen systems. It is intended as a ready reference for those considering the use of oxygen in aircraft and those wishing to familiarize themselves with the systems requirements for existing aircraft. This document is not intended to replace the oxygen related FAR but rather to index them in some order. For detailed information, the user is referred to the current issue of the relevant FAR paragraph referenced in this report.
Standard

Regulatory Requirements Covering the Use of Breathing Oxygen in Aircraft

2002-02-15
HISTORICAL
AIR1389A
This report presents, paraphrased in tabular format, an overview of the Federal Aviation Regulations (FAR) and the Joint Aviation Regulations (JAR) for aircraft oxygen systems. It is intended as a ready reference for those considering the use of oxygen in aircraft and those wishing to familiarize themselves with the systems requirements for existing aircraft. This document is not intended to replace the oxygen related FAR/JAR but rather to index them in some order. For detailed information, the user is referred to the current issue of the relevant FAR/JAR paragraph referenced in this report.
Standard

Chemical Oxygen Supplies

2014-10-30
CURRENT
AIR1133B
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2002-03-01
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Oxygen System Fill/Check Valve

1997-12-01
CURRENT
AS1225A
This SAE Aerospace Standard (AS) defines minimum standards of design, construction, and performance for two types of permanently installed, high pressure 12,800 kPa (1850 psig) and 13,800 kPa (2000 psig) oxygen system cylinder fill valves used in commercial aircraft. Refer to Purchaser's Specification for Requirements which are beyond the scope or level of detail provided in this document. One valve has an adjustable pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system. The second valve incorporates an automatic shutoff feature designed to limit system overpressurization in the event maintenance personnel do not stop system filling at the correct pressure. The intent of the fill valves is to control the rate of fill to limit the rise in temperature caused by compression heating to acceptable values, prevent oxygen back flow and prevent the ingestion of foreign matter that could cause contamination of the system.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2005-02-14
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
X