Refine Your Search

Topic

Search Results

Standard

Dynamic Testing Systems for Oxygen Breathing Equipment

1997-09-01
CURRENT
ARP1109B
This SAE Aerospace Recommended Practice (ARP) recommends performance requirements for test equipment used in dynamic testing of aviation oxygen breathing equipment. This document describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.
Standard

DYNAMIC TESTING SYSTEM FOR OXYGEN BREATHING EQUIPMENT

1969-04-01
HISTORICAL
ARP1109
This ARP covers a system and method to be used, at all appropriate altitudes, in testing of breathing oxygen systems consisting of demand regulator, connecting hose, and mask, or regulator and helmet systems, or individual components.
Standard

DYNAMIC TESTING SYSTEMS FOR OXYGEN BREATHING EQUIPMENT

1987-04-01
HISTORICAL
ARP1109A
This ARP describes test equipment and methods used for testing continuous flow, demand and pressure demand regulators and their associated masks as well as filtered protective breathing devices; such articles of oxygen breathing or protective breathing equipment may be tested as individual components or as a complete system.
Standard

Testing of Oxygen Equipment

2000-11-01
CURRENT
ARP1398A
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

TESTING OF OXYGEN EQUIPMENT

1989-02-01
HISTORICAL
ARP1398
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2012-10-15
CURRENT
ARP1320B
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

1991-01-01
HISTORICAL
ARP1320A
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

1965-10-01
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

OXYGEN MASKS FOR NON-MILITARY AIRPLANES

1956-12-01
HISTORICAL
AS452
This specification covers the types of oxygen masks considered satisfactory for use in commercial transport aircraft at altitudes up to 25,000 ft. The types of masks covered are:
Standard

Crewmember Demand Oxygen Mask For Transport Category Aircraft

1996-07-01
HISTORICAL
AS8026A
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Aviator's Breathing Oxygen Purity Standard

1997-09-01
HISTORICAL
AS8010C
This document defines the minimum degree of purity and maximum levels of certain deleterious impurities allowable for aviator's breathing oxygen at the point of manufacture or generation. It covers gaseous, liquid, and chemically generated oxygen, and oxygen supplied by in situ concentration and in situ electrolysis. Different limits are established for oxygen from different sources, in recognition of differences in the ways the oxygen is stored, dispensed, and utilized, taking into account the safety of the user. These limits are not intended to specifically reflect upon the relative capabilities or merits of various technologies. Procurement documents may specify more stringent limits, where required for specific applications. Medical oxygen is not covered by this standard. In the United States, medical oxygen is a prescription drug.
Standard

Reducers, Oxygen Pressure

1999-07-01
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Reducers, Oxygen Pressure

2012-07-24
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Glossary of Technical and Physiological Terms Related to Aerospace Oxygen Systems

2000-07-01
HISTORICAL
AIR171D
The scope of this document is to provide a list of specialized terms with their meanings. The glossary will assist the use of other documents related to aircraft oxygen equipment by defining ubiquitous terminology in context of this specialized field. The glossary contains terms of primary importance in the areas of chemistry, equipment, and physiology.