Refine Your Search

Topic

Search Results

Standard

Passenger Hypoxia Protection Utilizing Oxygen Enriched Gas Mixtures

2018-10-18
CURRENT
AIR6036
Currently, existing civil aviation standards address the design and certification of oxygen dispensing devices that utilize oxygen sources supplying at least 99.5% oxygen. This Aerospace Information Report discusses issues relating to the use in the passenger cabin of oxygen enriched breathing gas mixtures having an oxygen content of less than 99.5% and describes one method of showing that passenger oxygen dispensing devices provide suitable hypoxia protection when used with such mixtures.
Standard

Oxygen Sensor Technologies

2020-12-18
CURRENT
AIR5933
AIR5933 provides an overview of contemporary technologies (i.e., sensors) that measure the proportion of oxygen in a gas. The use of these sensors in the aerospace environment, with its special constraints, is discussed and papers/reports with detailed information are summarized and referenced. The sensors are divided into expendable and non-expendable sensors. Expendable sensors are based on electrochemical properties, whereas non-expendable sensors rely on paramagnetic, photo-acoustic, electromagnetic, and laser spectroscopy properties.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2011-06-21
HISTORICAL
ARP1320A
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2012-10-15
CURRENT
ARP1320B
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

MINIMUM STANDARD FOR OXYGEN PRESSURE REDUCERS

1991-09-01
HISTORICAL
AS1248
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2020-05-27
CURRENT
AS1248B
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

2004-06-23
HISTORICAL
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED

1971-07-01
HISTORICAL
AS1214
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2014-12-31
CURRENT
AIR1358C
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

OXYGEN MASKS FOR NON-MILITARY AIRPLANES

1956-12-01
HISTORICAL
AS452
This specification covers the types of oxygen masks considered satisfactory for use in commercial transport aircraft at altitudes up to 25,000 ft. The types of masks covered are:
X