Refine Your Search

Topic

Search Results

Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2000-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

1992-07-01
HISTORICAL
ARP599A
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downsteam side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

1996-05-01
HISTORICAL
ARP599
This test method describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers. The data obtained by this procedure do not necessarily indicate, qualitatively or quantitatively, the contamination which may be released by a filter element into a fluid during service use. Because of the wide variety of conditions which may exist in service applications, it is recommended that the user design and conduct his own particular service performance test. (See paragraph 10.1).
Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2008-06-22
CURRENT
ARP599D
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

2001-03-01
HISTORICAL
ARP743B
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful. These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2003-06-05
HISTORICAL
ARP725A
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2014-06-03
CURRENT
ARP725B
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2019-12-03
CURRENT
ARP900C
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures.
Standard

Methods for Evaluating Cryogenic Filters

1992-06-29
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2011-12-19
HISTORICAL
ARP900B
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters for particle sizes equal to or greater than 5.0 μm and flows up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document.
Standard

FINE WIRE MESH FOR FILTER ELEMENTS

1989-05-30
HISTORICAL
AIR888A
This AIR discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication, fuel systems and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.