Refine Your Search

Topic

Search Results

Standard

Aircraft Ground Service Connections Locations and Type

2006-06-05
HISTORICAL
ARP4084A
The purpose of this SAE Aerospace Recommended Practice (ARP) is to standardize locations of aircraft ground service connections to accommodate the trend toward fixed systems, which use the passenger loading bridge as a vehicle for a source of utilities. It must be recognized that, in standardizing the locations of the aircraft service connections, they must continue to be served efficiently in those instances where mobile ground support equipment is used. There is an ever increasing number of fixed installations for aircraft servicing. The objectives to be met by standardizing the locations of the aircraft service connections are the following:
Standard

Aircraft Ground Service Connections Locations and Type

2021-09-30
CURRENT
ARP4084B
The purpose of this SAE Aerospace Recommended Practice (ARP) is to standardize locations of aircraft ground service connections to accommodate the trend toward fixed systems, which use the passenger boarding bridge and/or underground “pop-up” or pit systems as a source of utilities. It must be recognized that, in standardizing the locations of the aircraft service connections, they must continue to be served efficiently in those instances where mobile ground support equipment is used. There is an ever increasing number of fixed installations for aircraft servicing. The objectives to be met by standardizing the locations of the aircraft service connections are the following:
Standard

Method of Testing Pre-Conditioned Air Equipment

2008-04-15
HISTORICAL
ARP5374A
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

EFFECTS OF NO-BREAK POWER TRANSFER ON 400 HZ AUXILIARY-POWER UNITS AND GROUND-POWER UNITS

1992-02-01
CURRENT
AIR4651
This SAE Aerospace Information Report (AIR) describes the characteristics and effects of using no-break power transfer (NBPT) methods when switching between auxiliary-power unit (APU) and ground-power unit (GPU). The GPU may be: a Point-of-use solid-state frequency converter, engine-generator, or motor-generator b Central system powered by motor-generator or solid-state frequency converter
Standard

Aircraft Damage Caused by Ground Support Equipment

2009-12-09
HISTORICAL
AIR1589A
Only those incidents where a piece of ground support equipment directly associated with the "turnaround" servicing of an aircraft was involved are reviewed. Specifically excluded are those incidents that occurred during heavy maintenance, overhaul activity, or aircraft taxiing.
Standard

Aircraft Damage Caused by Ground Support Equipment

2016-06-06
HISTORICAL
AIR1589B
Only those incidents where a piece of ground support equipment directly associated with the "turnaround" servicing of an aircraft was involved are reviewed. Specifically excluded are those incidents that occurred during heavy maintenance, overhaul activity, or aircraft taxiing.
Standard

Aircraft Damage Caused by Ground Support Equipment

2022-05-16
CURRENT
AIR1589C
Incidents where a piece of ground support equipment or personnel damages an aircraft under the control of ground or maintenance operations that requires corrective action by aircraft maintenance personnel. Operations include, but are not limited to servicing, line maintenance, heavy maintenance, and aircraft movement, e.g., marshalling/pushback/tow/reposition/taxi.
Standard

Measurement of Exterior Sound Level of Specialized Aircraft Ground Support Equipment

2006-10-13
HISTORICAL
ARP1801
The scope of this recommended practice covers specialized internal combustion engine powered equipment used in the support of aircraft operations. The equipment may be self-propelled, truck mounted, trailer mounted, skid mounted or stationary. It does not include construction equipment or equipment designed primarily for operation on highways or within factories or building areas.
Standard

TRANSMISSION INTERLOCKS

1996-05-01
HISTORICAL
AIR1361
The following recommendations and suggestions are made for consideration for procurement of new equipment, or modification to existing equipment where practical. Excluded from this AIR is mobile ground equipment, such as fork lift trucks and front end loaders, that have a functional requirement for simultaneous vehicle motion and accessory operation.
Standard

Transmission Interlocks

2012-07-31
CURRENT
AIR1361A
The following recommendations and suggestions are made for consideration for procurement of new equipment, or modification to existing equipment where practical. Excluded from this AIR is mobile ground equipment, such as fork lift trucks and front end loaders, that have a functional requirement for simultaneous vehicle motion and accessory operation.
Standard

Method of Evaluating Pneumatic Ground Power Units

2003-11-21
HISTORICAL
AIR4545
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Method of Evaluating Pneumatic Ground Power Units

2020-09-23
CURRENT
AIR4545A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

1999-01-01
HISTORICAL
AIR5373
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

2020-09-23
CURRENT
AIR5373A
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
X