This SAE Standard covers the measurement of Impulse Electric Field Strength radiated over the frequency range of 20–1000 MHz from a vehicle or other device powered by an internal combustion engine or electric motor. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form. Vehicle mounted rectifiers used for battery charging in electric vehicles are included in this specification when operated in their charging mode.
This standard covers the measurement of impulsive electromagnetic radiation over the frequency range of 20–1000 MHz from a vehicle or other device powered by an internal combustion engine or electric motor. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form. Vehicle mounted rectifiers used for battery charging in electric vehicles are included in this specification when operated in their charging mode.
This standard covers the measurement of impulsive electromagnetic radiation over the frequency range of 20 to 1(100 MHz from a motor vehicle or other device powered by an internal combustion engine. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form.
This SAE Standard contains limits1 and procedures for the measurement of radio disturbances in the frequency range of 150 kHz to 1000 MHz. The standard applies to any electronic/electrical component intended for use in vehicles and large devices. Refer to International Telecommunications Union (ITU) Publications for details of frequency allocations. The limits are intended to provide protection for receivers installed in a vehicle from disturbances produced by components/modules in the same vehicle.2 The receiver types to be protected are: sound and television receivers3, land mobile radio, radio telephone, amateur and citizens' radio. For the purpose of this document, a vehicle is a machine which is self-propelled. Vehicles include (but are not limited to) passenger cars, trucks, agricultural tractors, and snowmobiles. The limits in this document are recommended and subject to modification as agreed between the vehicle manufacturer and the component supplier.
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations.
This SAE Recommended Practice covers the recommended testing technique for determining the immunity of automotive electronic devices to magnetic fields generated by power transmission lines and generating stations.
This SAE Standard covers the recommended testing technique for determining the immunity of automotive electronic devices to magnetic fields generated by power transmission lines and generating stations.
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
The test procedures and performance levels in this SAE Recommended Practice cover the measurement of magnetic and electric field strengths over the frequency range 9 kHz to 30 MHz and conducted emissions over the frequency range of 450 kHz to 30 MHz1. Conducted emission measurements in this document are applicable only to battery-charging systems which utilize a switching frequency above 9 kHz, are mounted on the vehicle, and whose power is transferred by metallic conductors. Conducted emission requirements apply only during charging of the batteries from AC power lines. Conducted and radiated emissions measurements of battery-charging systems that use an induction power coupling device are not covered by this document. The measurement of electromagnetic disturbances for frequencies from 30 MHz to 1000 MHz and narrowband electromagnetic disturbances for frequencies from 150 kHz to 30 MHz are covered in SAE J551-2.
The test procedures and performance levels in this SAE Recommended Practice cover the measurement of magnetic and electric field strengths over the frequency range 9 kHz to 30 MHz. The measurement of electromagnetic disturbances for frequencies from 30 MHz to 1000 MHz is covered in SAE J551/2.
The test procedures and performance levels in this SAE Recommended Practice cover the measurement of magnetic and electric field strengths over the frequency range 9 kHz to 30 MHz and conducted emissions over the frequency range of 450 kHz to 30 MHz1. Conducted emission measurements in this document are applicable only to battery-charging systems which utilize a switching frequency above 9 KHz, are mounted on the vehicle, and whose power is transferred by metallic conductors. Conducted emission requirements apply only during charging of the batteries from AC power lines. Conducted and radiated emissions measurements of battery-charging systems that use an induction power coupling device are not covered by this document. The measurement of electromagnetic disturbances for frequencies from 30 MHz to 1000 MHz and narrowband electromagnetic disturbances for frequencies from 150 KHz to 30 MHz are covered in SAE J551-2.
This SAE Recommended Practice specifies measurement procedures and performance levels for magnetic and electric field emissions and conducted power mains emissions over the frequency range 150 kHz to 30 MHz, for vehicles incorporating electric propulsion systems, e.g., battery, hybrid, or plug-in hybrid electric vehicles. Conducted emission measurements in this document are applicable only to battery-charging systems which utilize a switching frequency above 9 kHz, are mounted on the vehicle, and whose power is transferred by metallic conductors. Conducted emission requirements apply only during charging of the batteries from AC power lines. Conducted and radiated emissions measurements of battery-charging systems that use an induction power coupling device are not covered by this document. The measurement of electromagnetic disturbances for frequencies from 30 MHz to 1000 MHz is covered in CISPR 12.
This SAE Standard establishes a common basis for the evaluation of devices and equipment in vehicles against transient transmission by coupling via lines other than the power supply lines. The test demonstrates the immunity of the instrument, device, or equipment to coupled fast transient disturbances, such as those caused by switching of inductive loads, relay contact bouncing, etc. Two test methods are presented - Coupling Clamp and Chattering Relay.