Refine Your Search

Topic

Search Results

Standard

ELECTROMAGNETIC SUSCEPTIBILITY PROCEDURES FOR VEHICLE COMPONENTS (EXCEPT AIRCRAFT)

1984-06-01
HISTORICAL
J1113_198406
This SAE Recommended Practice establishes uniform laboratory measurement techniques for the determination of the susceptibility to undesired electromagnetic sources of electrical, electronic, and electromechanical ground-vehicle components. It is intended as a guide toward standard practice, but may be subject to frequent change to keep pace with experience and technical advances, and this should be kept in mind when considering its use.
Standard

ELECTROMAGNETIC SUSCEPTIBILITY PROCEDURES FOR VEHICLE COMPONENTS (EXCEPT AIRCRAFT)

1978-06-01
HISTORICAL
J1113A_197806
This SAE Recommended Practice establishes uniform laboratory measurement techniques for the determination of the susceptibility to undesired electromagnetic sources of electrical, electronic, and electromechanical ground-vehicle components. It is intended as a guide toward standard practice but may be subject to frequent change to keep pace with experience and technical advances, and this should be kept in mind when considering its use.
Standard

VEHICLE ELECTROMAGNETIC RADIATED SUSCEPTIBILITY TESTING USING A LARGE TEM CELL

1982-08-01
HISTORICAL
J1407_198208
This information report gives the procedures for use and operation of a large transverse electromagnetic (TEM) mode cell for the determination of electromagnetic (EM) radiated susceptibility of equipment, subsystems and systems (whose dimensions are less than 3 m × 6 m × 18 m) in the frequency range 10 kHz–20 MHz. Several large TEM cells have been designed and constructed by various organizations for EMP and high power CW testing. Two cell designs and associated instrumentation are included for example purposes in this report. Other cell configurations have also been constructed. Users should consult the literature before undertaking a project of this magnitude for other cell and instrumentation designs.
Standard

VEHICLE ELECTROMAGNETIC RADIATED SUSCEPTIBILITY TESTING USING A LARGE TEM CELL

1988-03-01
HISTORICAL
J1407_198803
This information report gives the procedures for use and operation of a large transverse electromagnetic (TEM) mode cell for the determination of electromagnetic (EM) radiated susceptibility of equipment, subsystems and systems (whose dimensions are less than 3 m × 6 m × 18 m) in the frequency range 10 kHz - 20 MHz. Several large TEM cells have been designed and constructed by various organizations for EMP and high power CW testing. Two cell designs and associated instrumentation are included for example purposes in this report. Other cell configurations have also been constructed. Users should consult the literature before undertaking a project of this magnitude for other cell and instrumentation designs.
Standard

MEASUREMENT OF ELECTROMAGNETIC RADIATION FROM MOTOR VEHICLES (20-1000 MHz)

1968-08-01
HISTORICAL
J551A_196808
This standard covers the measurement of radiation from all motor vehicle sources (including auxiliary engines) with the exception of short duty cycle equipment, such as starting motors, window regulators, turn signals, etc., over a frequency range of 20-1000 MHz.
Standard

MEASUREMENT OF ELECTROMAGNETIC RADIATION FROM A MOTOR VEHICLE OR OTHER INTERNAL-COMBUSTION-POWERED DEVICE (EXCLUDING AIRCRAFT) (20-1000 MHz)

1974-02-01
HISTORICAL
J551C_197402
This standard covers the measurement of electromagnetic radiation from a motor vehicle or other internal-combustion-powered device (excluding aircraft) over a frequency range of 20-1000 MHz. In the case of motor vehicle sources, auxiliary engines mounted on the vehicle are included and short-duty cycle equipment (such as starting motors, window regulators, turn signals, flashing warning lights, etc.) are excluded.
Standard

MEASUREMENT OF ELECTROMAGNETIC RADIATION FROM MOTOR VEHICLES (20-1000 MHz)

1972-11-01
HISTORICAL
J551A_197211
This standard covers the measurement of radiation from all motor vehicle sources (including auxiliary engines) with the exception of short duty cycle equipment, such as starting motors, window regulators, turn signals, etc., over a frequency range of 20-1000 MHz.
Standard

Vehicle Electromagnetic Immunity—Power Line Magnetic Fields

2010-01-07
HISTORICAL
J551/17_201001
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
Standard

Vehicle Electromagnetic Immunity - Power Line Magnetic Fields

2015-07-22
CURRENT
J551/17_201507
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
Standard

Electromagnetic Compatibility Measurement Procedure for Vehicle Components - Immunity to AC Power Line Electric Fields

2014-04-16
HISTORICAL
J1113/26_201404
This SAE Recommended Practice covers the recommended testing techniques for the determination of electric field immunity of an automotive electronic device when the device and its wiring harness is exposed to a power line electric field. This technique uses a parallel plate field generator and a high voltage, low current voltage source to produce the field.
Standard

Conducted Immunity, 250 kHz to 400 MHz, Direct Injection of Radio Frequency (RF) Power

2010-08-05
CURRENT
J1113/3_201008
This part of SAE J1113 specifies the direct RF power injection test method and procedure for testing electromagnetic immunity of electronic components for passenger cars and commercial vehicles. The electromagnetic disturbances considered in this part of SAE J1113 are limited to continuous, narrowband conducted RF energy. This test method is applicable to all DUT leads except the RF reference ground. The test provides differential mode excitation to the DUT. Immunity measurements of complete vehicles are generally only possible by the vehicle manufacturer. The reasons, for example, are high costs of a large absorber-lined chamber, preserving the secrecy of prototypes or the large number of different vehicle models. Therefore, for research, development, and quality control, a laboratory measuring method for components shall be applied by the manufacturer. This method is suitable over the frequency range of 250 kHz to 400 MHz.
Standard

Measurement of Radiated Emissions from Integrated Circuits—Surface Scan Method (Loop Probe Method) 10 MHz to 3 GHz

2016-09-16
CURRENT
J1752/2_201609
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
Standard

Measurement of Radiated Emissions from Integrated Circuits—Surface Scan Method (Loop Probe Method) 10 MHz to 3 GHz

2011-06-24
HISTORICAL
J1752/2_201106
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
Standard

Performance Levels and Methods of Measurement of Magnetic and Electric Field Strength from Electric Vehicles, Broadband, 9 kHz to 30 MHz

1997-12-01
HISTORICAL
J551/5_199712
The test procedures and performance levels in this SAE Recommended Practice cover the measurement of magnetic and electric field strengths over the frequency range 9 kHz to 30 MHz and conducted emissions over the frequency range of 450 kHz to 30 MHz1. Conducted emission measurements in this document are applicable only to battery-charging systems which utilize a switching frequency above 9 kHz, are mounted on the vehicle, and whose power is transferred by metallic conductors. Conducted emission requirements apply only during charging of the batteries from AC power lines. Conducted and radiated emissions measurements of battery-charging systems that use an induction power coupling device are not covered by this document. The measurement of electromagnetic disturbances for frequencies from 30 MHz to 1000 MHz and narrowband electromagnetic disturbances for frequencies from 150 kHz to 30 MHz are covered in SAE J551-2.
X