Refine Your Search

Topic

Search Results

Standard

Cautionary Statements for Handling Hfc-134a During Mobile Air Conditioning Service

1998-08-28
CURRENT
J1629_199808
The cautionary statements presented in this SAE Information Report are to be included in all current and future SAE Standards involving service practices (J2211) and service equipment (J2210) for HFC-134a refrigerant. It is also intended that these cautionary statements (or equivalent language) be recommended for inclusion in all publications dealing with the servicing of HFC-134a mobile air conditioning systems.
Standard

HFC-134a (R-134a) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1998-11-01
HISTORICAL
J1732_199811
The purpose of this SAE Standard is to provide equipment specifications for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2210 specifications by using Design Certified equipment of the same ownership. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system, with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
Standard

Criteria for Refrigerant Identification Equipment for Use with Mobile Air-Conditioning Systems

1998-11-09
HISTORICAL
J1771_199811
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant CFC-12 (R-12) and HFC-134a (R-134a) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer.
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

1998-11-01
HISTORICAL
J1661_199811
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

PASSENGER CAR BACKLIGHT DEFOGGING SYSTEM

1999-02-01
HISTORICAL
J953_199902
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at −18 °C. A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 4 °C. The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
Standard

PASSENGER CAR BACKLIGHT DEFOGGING SYSTEM

1984-06-01
HISTORICAL
J953_198406
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at 0°F (−18°C). A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 40°F (4°C). The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
Standard

Passenger Car Backlight Defogging System

1966-05-01
HISTORICAL
J953_196605
The scope of this SAE Recommended Practice is to establish uniform test procedures and minimum performance requirements for sedan passenger car backlight defogging systems. It is limited to tests that can be conducted on uniform test equipment in commercially available laboratory facilities. The test procedures and minimum performance requirements, outlined in this recommended practice, are based on currently available engineering data. It is the intent that all portions of the recommended practice will be periodically reviewed and revised as additional knowledge regarding defogging performance is developed.
Standard

Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J1990_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-03-01
HISTORICAL
J1990_199203
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 air-conditioning systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile air-conditioning system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

STANDARD OF PURITY FOR USE IN MOBILE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1991_198910
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically seated, rigid pipe are not covered in this document.
Standard

Standard of Purity for Use in Mobile Air-Conditioning Systems

1999-02-01
HISTORICAL
J1991_199902
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed, rigid pipe, are not covered in this document.
Standard

Recommended Service Procedure for the Containment of CFC-12 (R-12)

1998-11-09
HISTORICAL
J1989_199811
During service of mobile air-conditioning (A/C) systems, containment of the refrigerant is important. This procedure provides service guidelines for technicians when repairing vehicles and operating equipment defined in SAE J1990.
Standard

CFC-12 (R-12) EXTRACTION EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-06-01
HISTORICAL
J2209_199206
The purpose of this SAE Recommended Practice is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to ARI standard 700-88 as a minimum (Air Conditioning and Refrigerant Institute). It is not acceptable that the refrigerant removed from a mobile air-conditioning system, with this equipment, be directly returned to a mobile air-conditioning system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar R-12 systems.
Standard

CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J2209_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

PERFORMANCE CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1995-08-01
HISTORICAL
J1627_199508
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

RATING CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1993-06-01
HISTORICAL
J1627_199306
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

Vehicle Testing Requirements for Replacement Refrigerants for CFC-12 (R-12) Mobile Air-Conditioning Systems

1999-02-01
HISTORICAL
J1659_199902
The purpose of this SAE Recommended Practice is to establish the specific criteria for the selection of a replacement refrigerant for mobile CFC-12 (R-12) air-conditioning (A/C) systems. This document provides guidelines for qualifying candidate refrigerant. The requirements include laboratory and field testing. The alternate refrigerant shall provide comparable system performance as CFC-12 (R-12) as defined herein. The vehicle testing shall be conducted on representative vehicle manufacturer's product line, in which the refrigerant is intended to be used, such as cycling clutch orifice tube, constant run orifice tube, cycling clutch expansion valve, or continuous run expansion valve refrigerant system. This document is complete only when combined with the requirements of SAE J1657.
X