Refine Your Search

Topic

Search Results

Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2007-01-08
HISTORICAL
J2777_200701
With many corporations and suppliers conducting development and validation tests at different Climatic Wind Tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to obtain similar results, independent of location, for Heating Ventilation and Air Conditioning (HVAC) and Powertrain Cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives. Therefore a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2022-11-14
CURRENT
J2777_202211
With many corporations and suppliers conducting development and validation tests at different climatic wind tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to correlate results from different facilities, independent of location, for heating ventilation and air conditioning (HVAC) and powertrain cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives; therefore, a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2016-01-14
HISTORICAL
J2777_201601
With many corporations and suppliers conducting development and validation tests at different Climatic Wind Tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to obtain similar results, independent of location, for Heating Ventilation and Air Conditioning (HVAC) and Powertrain Cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives. Therefore a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Vehicle Testing Requirements for Replacement Refrigerants for CFC-12 (R-12) Mobile Air-Conditioning Systems

2011-11-21
CURRENT
J1659_201111
The purpose of this SAE Recommended Practice is to establish the specific criteria for the selection of a replacement refrigerant for mobile CFC-12 (R-12) air-conditioning (A/C) systems. This document provides guidelines for qualifying candidate refrigerant. The requirements include laboratory and field testing. The alternate refrigerant shall provide comparable system performance as CFC-12 (R-12) as defined herein. The vehicle testing shall be conducted on representative vehicle manufacturer’s product line, in which the refrigerant is intended to be used, such as cycling clutch orifice tube, constant run orifice tube, cycling clutch expansion valve, or continuous run expansion valve refrigerant system. This document is complete only when combined with the requirements of SAE J1657.
Standard

Recommended Practice for an Engineering Analysis for A/C Efficiency Credits

2019-07-18
HISTORICAL
J3174_201907
Under U.S. GHG and CAFE regulations, manufacturers are required to perform confirmatory testing to validate indirect air conditioning credits (refer to 40 CFR 86.1868-12). The purpose of this Reccomended Practice is to provide manufacturers with updated criteria for the 2020 and later model years. This Recommended Practice discribes the work done by the IMAC GHG CRP to develop test procedures, publish SAE Standards, and determine performance requirements to demonstrate the performance of A/C technologies from the pre-approved credit menu meeting regulatory requirements. Also, enclosed in this Recommended Practice are instructions that can be used by vehicle manufacturers in establishing an engineering analysis in lieu of performing the AC17 test on a vehicle which does not incorporate the credit-generating technologies.
Standard

Recommended Practice for an Engineering Analysis for A/C Efficiency Credits

2022-09-08
CURRENT
J3174_202209
Under U.S. GHG and CAFE regulations, manufacturers are required to perform confirmatory testing to validate indirect air conditioning credits (refer to 40 CFR 86.1868-12). The purpose of this SAE Recommended Practice is to provide manufacturers with updated criteria for the 2020 and later model years. This SAE Recommended Practice is also suitable for reporting credit using and Engineering Analysis to the California Air Resources Board (CARB). This SAE Recommended Practice describes the work done by the IMAC GHG CRP to develop test procedures, publish SAE Standards, and determine performance requirements to demonstrate the performance of A/C technologies from the pre-approved credit menu meeting regulatory requirements. Also, enclosed in this SAE Recommended Practice are instructions that can be used by vehicle manufacturers in establishing an engineering analysis in lieu of performing the AC17 test on a vehicle which does not incorporate the credit-generating technologies.
Standard

Test Procedure for Internal Heat Exchangers of Mobile Air-Conditioning Systems with R-134a or R-1234yf Refrigerant

2023-02-14
CURRENT
J3094_202302
The purpose of this SAE Standard is to define a common set of thermodynamic test conditions to evaluate internal heat exchangers for use with R-134a and R-1234yf refrigerants in mobile air-conditioning systems. This SAE Standard can be used to test actual vehicle IHX designs or standardized IHX samples, which can be used for comparison based on a common length and shape.
Standard

Test Procedure for Internal Heat Exchangers of Mobile Air-Conditioning Systems with R-134a or R-1234yf Refrigerant

2019-02-15
HISTORICAL
J3094_201902
The purpose of this SAE Standard is to define a common set of thermodynamic test conditions to evaluate internal heat exchangers for use with R-134a and R-1234yf refrigerants in mobile air-conditioning systems. This standard can be used to test actual vehicle IHX designs or standardized IHX samples, which can be used for comparison based on a common length and shape.
Standard

Test Procedure for Internal Heat Exchangers of Mobile Air-Conditioning Systems with R-134a or R-1234yf Refrigerant

2020-04-02
HISTORICAL
J3094_202004
The purpose of this SAE Standard is to define a common set of thermodynamic test conditions to evaluate internal heat exchangers for use with R-134a and R-1234yf refrigerants in mobile air-conditioning systems. This standard can be used to test actual vehicle IHX designs or standardized IHX samples, which can be used for comparison based on a common length and shape.
Standard

Standard for Refrigerant Risk Analysis for Mobile Air Conditioning Systems

2011-02-04
HISTORICAL
J2773_201102
This Standard describes methods to understand the risks associated with vehicle mobile air conditioning [MAC] systems in all aspects of a vehicle’s lifecycle including design, production, assembly, operation and end of life. Information for input to the risk assessment is provided in the Appendices of this document. This information should not be considered to be complete, but only a reference of some of the data needed for a complete analysis of the risk associated with the use of refrigerants in MAC systems.
Standard

Standard for Refrigerant Risk Analysis for Mobile Air Conditioning Systems

2020-05-15
CURRENT
J2773_202005
This SAE Standard describes methods to understand the risks associated with vehicle mobile air conditioning (MAC) systems in all aspects of a vehicle’s lifecycle including design, production, assembly, operation, and end of life. Information for input to the risk assessment is provided in the appendices of this document. This information should not be considered to be complete, but only a reference of some of the data needed for a complete analysis of the risk associated with the use of refrigerants in MAC systems.
Standard

Standard for Refrigerant Risk Analysis for Mobile Air Conditioning Systems

2017-02-21
HISTORICAL
J2773_201702
This Standard describes methods to understand the risks associated with vehicle mobile air conditioning [MAC] systems in all aspects of a vehicle’s lifecycle including design, production, assembly, operation and end of life. Information for input to the risk assessment is provided in the Appendices of this document. This information should not be considered to be complete, but only a reference of some of the data needed for a complete analysis of the risk associated with the use of refrigerants in MAC systems.
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2019-09-03
CURRENT
J2772_201909
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate refrigerant concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 (CO2) and R-1234yf (HFO-1234yf), but the general techniques described here can be used for other refrigerants as well.
Standard

Life Cycle Analysis to Estimate the CO2-Equivalent Emissions from MAC Operation

2009-02-16
HISTORICAL
J2766_200902
This recommended best practice outlines a method for estimating CO2-Equivalent emissions using the GREEN-MAC-LCCP© (Global Refrigerants Energy and ENvironmental – Mobile Air Conditioning – Life Cycle Climate Performance) model (also referred to as “the model” in this standard).
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2011-02-04
HISTORICAL
J2772_201102
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC-Module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 [CO2] and R-1234yf [HFO-1234yf], but the general techniques described here can be used for other refrigerants as well.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compression Systems

2011-12-19
HISTORICAL
J639_201112
This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks and commercial vehicles (on and off road) that use automotive type mobile air conditioning [MAC] systems. Large trucks, buses and other vehicles that do not use typical automotive a/c systems or use refrigerants not listed in this document are not covered by this standard. This standard covers any vehicle with a MAC system using a belt or electric motor driven compressor. This document provides standards for design, assembly, test and service of MAC systems to minimize environmental, health and safety impacts. Also included are cautionary statements for the service industry to alert technicians to the inadvisability and possible health or safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for mobile air conditioning applications.
Standard

Mobile Air Conditioning System Refrigerant Emission Charts for R-134a, R-1234yf, and R-152a

2020-11-30
HISTORICAL
J2727_202011
The “system emissions chart” contained herein is intended to serve as a means of estimating the annual refrigerant emission rate (grams per year) from new production A/C systems equipped with specified component technologies. It provides emission values for various component technologies that are currently available, and can be expanded as new technologies are commercialized. This document provides the information to develop an Excel file template “system emissions chart” for system emission analysis. The chart includes automotive compressor technologies for conventional mobile air conditioning systems, as well as those using semi-hermetic compressors. This standard can be considered a companion document to SAE J2763. SAE J2727 estimates system emissions, taking into account production assembly variation and accounts for components that are 100% helium leak tested prior to vehicle final assembly.
X