Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

The AMS-TOF and ECAL Thermal Tests in Vacuum at SERMS

2007-07-09
2007-01-3023
The AMS-02 experiment is a space-born instrument designed to perform high precision measurements of cosmic rays and γ-ray fluxes on board of the International Space Station (ISS). All the components of the AMS experiment are designed to withstand the mechanical stresses in the launch phase and to operate in vacuum in a wide range of temperatures. In order to verify the performance of the hardware in harsh conditions like the flight ones, all the components of the AMS instruments undergo a severe qualification procedure before the integration into the detector. In this paper, we will report on the thermo-vacuum tests on the L-TOF (Lower Time of Flight) and ECAL (Electromagnetic CALorimeter) detectors, successfully performed in the SERMS laboratory in June and September 2006, respectively.
Technical Paper

Alpha Magnetic Spectrometer (AMS-02) Thermal Control Verification Philosophy

2007-07-09
2007-01-3164
This paper reports on the approach followed for the TCS verification of the payload AMS-02 (Alpha Magnetic Spectrometer), aiming at the qualification of the entire system, in steps, for the space environment. AMS-02 is a state-of-the-art experiment composed by a stack of seven different particle detectors, each of them having its own electronics and control equipments. It will be installed on the International Space Station Starboard segment S3 of the main Truss, and will be a 6500 kg payload, with a power consumption of 2000 W. The verification philosophy is driven by the need to qualify the flight hardware and by the necessary confirmation and correlation of the thermal mathematical models, based on experimental data. The hardware used on AMS-02 is derived from the state-of-the-art ground based detectors for high energy physics, hence not yet proven for operations in vacuum and in extreme thermal environment.
Technical Paper

Test-Model Correlation in Spacecraft Thermal Control by Means of MonteCarlo Techniques

2007-07-09
2007-01-3120
In the paper some methods are presented, with the corresponding practical examples, related to MonteCarlo (MC) techniques for thermal model/test correlation purposes. The MonteCarlo techniques applied to model correlation are intended to be used as an alternative to empirical ‘manual’ correlation techniques, gradients methods, matrix methods based on least square fit minimization. First of all, Design Of Experiments (DoE) tools are used to determine the model response to uncertain parameters and the confidence level of such a response. A sensitivity map is built, allowing the design of the test to maximize the response of the system to the uncertain parameters. Techniques derived from the extreme statistics are used to extrapolate data beyond test limits, with a sufficient confidence in the queue behaviour.
Technical Paper

Thermal Testing of a Heat Switch for European Mars Rover

2009-07-12
2009-01-2573
A Heat Switch has been developed, namely a device able to autonomously regulate its own thermal conductance in function of the equipment dissipation and environmental heat sink conditions. It is based on a Loop Heat Pipe (LHP) technology, with a passive bypass valve which diverts the flow to the Compensation Chamber when needed for regulation purposes. The target application is the potential use on a Mars Rover thermal control system. The paper recalls the Heat Switch design, and reports the results of an extensive test campaign on the ground demonstrator. The performance of the device was found extremely satisfying, and often exceeded the system requirements.
Technical Paper

Thermal Analysis for Systems Perturbed in the Linear Domain Method Development and Numerical Validation

2005-07-11
2005-01-3056
Improvements on the thermal analysis for system perturbed by micro-thermal fluctuations are presented: the method applies to any kind of (small) perturbation, in particular to the random ones. Opposite to time domain conventional transient analysis, this method answers the need for frequency domain thermal analysis dictated by the newest scientific missions, with tight temperature stability requirements (expressed in the frequency domain). The small temperature fluctuations allow for assuming any thermal systems a linear one; hence linear system theory holds, and powerful tools to calculate key parameters like frequency response can be successfully employed. MIMO (Multi-Input-Multi-Output) systems theory is applied, the inputs being perturbations to the thermal system (boundary temperatures oscillations and power sources ripple of any shape: pulse, step, periodic, random, …), while the outputs are the temperatures of the sensible parts.
X