Refine Your Search

Topic

Search Results

Standard

Flight Deck Interior Doors and Their Operation

2003-11-14
CURRENT
ARP807A
The purpose of this Aerospace Recommended Practice is to provide recommendations which will lead to the standardization of flight deck interior doors and their operation in all transport aircraft by establishing design criteria which will provide optimum use under normal and emergency conditions. The flight deck interior door is that door which connects the flight deck area with any cabin area or area leading to any cabin area, whether passenger or cargo, and does not include any door leading from the flight deck directly to the outside of the aircraft.
Standard

Lavatory Smoke Detectors

2006-02-17
HISTORICAL
ARP4001A
The purpose of this SAE Aerospace Recommended Practice (ARP) is to describe key features that should be incorporated in the lavatory smoke detector system. Consideration has been given to existing requirements of the FAA and to recommendations of aircraft operators and manufacturers. This document is deliberately not specific in all areas in order to maximize the freedom to use state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the document.
Standard

Lavatory Smoke Detectors

2012-05-25
CURRENT
ARP4001B
The purpose of this SAE Aerospace Recommended Practice (ARP) is to describe key features that should be incorporated in the lavatory smoke detector system. Consideration has been given to existing requirements of the FAA and to recommendations of aircraft operators and manufacturers. This document is deliberately not specific in all areas in order to maximize the freedom to use state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the document.
Standard

LAVATORY SMOKE DETECTORS

1990-01-18
HISTORICAL
ARP4001
This ARP is to describe key features for the lavatory smoke detector. Consideration has been given to existing requirements of the FAA, to recommendations of aircraft operators and manufacturers. The ARP is deliberately not specific in all areas in order to maximize potential supplier's freedom to use the state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the ARP.
Standard

Aircraft Evacuation Signal System

2022-08-05
CURRENT
ARP1178C
This SAE Aerospace Recommended Practice recommends general criteria for the development and installation of an aircraft emergency signal system to permit any crew member (flight or cabin) to inform all other crew members that an emergency evacuation situation exists and that an evacuation has been or should be immediately started.
Standard

Aircraft Evacuation Signal System

1998-06-01
HISTORICAL
ARP1178A
This SAE Aerospace Recommended Practice (ARP) establishes the criteria for the development and installation of an aircraft emergency signal system to permit any crew member to inform all other crew members that an emergency evacuation situation exists and that an evacuation has been or should be immediately started.
Standard

Lavatory Installation

1998-04-01
HISTORICAL
ARP1315C
This SAE Aerospace Recommended Practice (ARP) establishes recommendations with respect to personnel and aircraft safety for the design of lavatory compartments in commercial aircraft. Consideration should be given to the fact the lavatory compartment is an area in which the passenger is not under direct observation of the flight attendants.
Standard

LAVATORY INSTALLATION

1992-03-05
HISTORICAL
ARP1315B
This SAE Aerospace Recommended Practice (ARP) establishes recommendations with respect to personnel and aircraft safety for the design of lavatory compartments in commercial aircraft. Consideration should be given to the fact the lavatory compartment is an area in which the passenger is not under direct observation of the flight attendants.
Standard

Safety Instructions for Sight-Impaired Passengers

2014-04-14
CURRENT
ARP5446A
These recommendations are provided to aid the international air transport industry by identifying a standard, minimum amount of safety instructions that should be given to sight-impaired passengers. This document is not meant to address problems associated with communicating safety information to sight-impaired passengers who are also hearing impaired or non-conversant in the language(s) used by the cabin crew to disseminate general safety information to passengers. Aircraft operators are encouraged to customize the safety instructions for their own operations in order to ensure that required safety information is provided to sight-impaired passengers.
Standard

Design and Performance Criteria: Interior Passenger Stairways on Transport Category Airplanes

2020-06-25
CURRENT
AS5671
This SAE Aerospace Standard (AS) provides design criteria for onboard stairways intended for use by passengers aboard multi-deck transport category airplanes. It is not intended for stairways designed for use only by crewmembers, supernumeries, or maintenance personnel. Additionally, this AS does not apply to fuselage mounted or external stairways used for boarding passengers, which are covered by ARP836.
Standard

Exits and Their Operation - Air Transport Cabin Emergency

2000-03-01
HISTORICAL
ARP488D
The scope of this Aerospace Recommended Practice (ARP) is to provide design recommendations for passenger cabin entry doors, service doors, and emergency exits. The objective is to have a reliable system standardized to make operation of the exits simple, quick and obvious to all occupants under normal and emergency conditions and facilitate qualification of cabin attendants for different airplanes.
X