Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
CURRENT
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Circuit Breakers

1988-06-01
HISTORICAL
J553_198806
This SAE Standard defines the test conditions, procedures and performance requirements for circuit breakers in ratings up to and including 50A. The document includes externally or internally mounted automatic reset, modified reset, and manually reset types of circuit breakers for 12V and 24V DC operation. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Circuit Breakers

1992-06-01
HISTORICAL
J553_199206
This SAE Standard defines the test conditions, procedures and performance requirements for circuit breakers in ratings up to and including 50A. The document includes externally or internally mounted automatic reset, modified reset, and manually reset types of circuit breakers for 12V and 24V DC operation. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Circuit Breakers

2016-07-12
CURRENT
J553_201607
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
CURRENT
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
HISTORICAL
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Circuit Breaker--Internal Mounted--Automatic Reset

1971-06-01
HISTORICAL
J258_197106
An internally mounted circuit breaker is one mounted within an automotive switch or other automotive device for protection against overload of the wiring. In a given application,, this same circuit breaker may be designed to protect against overload of the electrically operable devices.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
CURRENT
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Seven Conductor Cable - Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2012-08-14
HISTORICAL
J1067_201208
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2016-10-25
CURRENT
J1067_201610
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Heavy-Duty Circuit Breakers

2013-05-03
CURRENT
J1625_201305
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Seven-Conductor Cable for ABS Power

1998-06-01
HISTORICAL
J2394_199806
This SAE Standard establishes the minimum construction and performance requirements for seven-conductor 1/8-2/10-4/12 cable for use on trucks and trailers. Where appropriate, the document refers to two types of cables, (Type F and S, described later in the document), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable for ABS Power--Truck and Bus

2007-06-22
HISTORICAL
J2394_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8 2/10 4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document's title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.