Refine Your Search

Topic

Search Results

Viewing 1 to 19 of 19
Journal Article

The Energy Management for Solar Powered Vehicle Parking Ventilation System

2015-04-14
2015-01-0149
In summer, when vehicle parks in direct sunlight, the closed cabin temperature would rise sharply, which affects the occupants step-in-car comfort Solar powered vehicle parking ventilation system adopts the solar energy to drive the original ventilator. Thus, the cabin temperature could be dramatically decreased and the riding comfort could be also improved. This research analyzed the modified crew cabin thermal transfer model. Then the performance of the solar powered ventilation system is analyzed and optimized combined with the power supply characteristics of the photovoltaic element. The storage and reuse of the solar power is achieved on condition that the cabin temperature could be steadily controlled. The research shows that, the internal temperature is mainly affected by the solar radiation intensity and the environment temperature.
Journal Article

Boiling Coolant Vapor Fraction Analysis for Cooling the Hydraulic Retarder

2015-04-14
2015-01-1611
The hydraulic retarder is the most stabilized auxiliary braking system [1-2] of heavy-duty vehicles. When the hydraulic retarder is working during auxiliary braking, all of the braking energy is transferred into the thermal energy of the transmission medium of the working wheel. Theoretically, the residual heat-sinking capability of the engine could be used to cool down the transmission medium of the hydraulic retarder, in order to ensure the proper functioning of the hydraulic retarder. Never the less, the hydraulic retarder is always placed at the tailing head of the gearbox, far from the engine, long cooling circuits, which increases the risky leakage risk of the transmission medium. What's more, the development trend of heavy load and high speed vehicle directs the significant increase in the thermal load of the hydraulic retarder, which even higher than the engine power.
Technical Paper

Strength Analysis and Modal Analysis of Hydraulic Retarder

2009-10-06
2009-01-2896
Hydraulic retarder is one of main auxiliary braking devices of the vehicle. When the vehicle is braking, a great pressure from high-speed fluid is received by hydraulic retarder blades. It is difficult to predict rational hydraulic retarder strength, owing to the complexity of the internal flow of oil. An optimal calculation way of hydraulic retarder strength is proposed based on CFD and FEA, concluding a reasonable result. The 3-D model of hydraulic retarder is built in the general CAD software. The model of fluid passage is extracted, according to the condition when the whole flow passage is filled with oil, and imported to CFD software. The inner flow field of hydraulic retarder is analyzed and the hydraulic surface pressure distribution of the hydraulic retarder blade is obtained at the highest rotary speed of turbine wheel.
Technical Paper

Heavy Truck Driveline Components Modeling and Thermal Analyzing

2009-10-06
2009-01-2905
In heavy truck driveline system, the components often include clutch, transmission, transfer case, drive shaft, etc. A fluid torque converter could be equipped in front of the transmission in order to improve the starting performance. Meanwhile, a hydraulic retarder could be introduced for auxiliary braking so as to adapt the truck to the brake on long downgrade in mountainous regions. Thus, the driveline heat load would have a notable increase. Both the fluid torque converter and the hydraulic retarder would produce a large quantity of heat, and a special cooling system is needed for adjusting the transmission fluid temperature with which the gains are potentially very large [1]. The heat load for driveline is often calculated based on empirical formula. For the heavy truck, however, if the heat value is underestimated, driveline components would suffer from overheated damage.
Technical Paper

Model-Based Pressure Control for an Electro Hydraulic Brake System on RCP Test Environment

2016-09-18
2016-01-1954
In this paper a new pressure control method of a modified accumulator-type Electro-hydraulic Braking System (EHB) is proposed. The system is composed of a hydraulic motor pump, an accumulator, an integrated master cylinder, a pedal feel simulator, valves and pipelines. Two pressurizing modes are switched between by-motor and by-accumulator to adapt different pressure boost demands. A differentiator filtering raw sensor signal and calculating pedal speed is designed. By using the pedal feel simulator, the relationship between wheel pressures and brake force is decoupled. The relationships among pedal displacement, pedal force and wheel pressure are calibrated by experiments. A model-based PI controller with predictor is designed to lower the influences caused by delay. Moreover, a self-tuning regulator is introduced to deal with the parameter’s time-varying caused by temperature, brake pads wearing and delay variation.
Technical Paper

Energy Saving Analysis of Vehicle Hydraulic Retarder Thermal Management System Based on Rankine Cycle

2016-09-18
2016-01-1941
Vehicle hydraulic retarders are applied in heavy-duty trucks and buses as an auxiliary braking device. In traditional cooling systems of hydraulic retarders, the working fluid is introduced into the heat exchanger to transfer heat to the cooling liquid in circulation, whose heat is then dissipated by the engine cooling system. This prevents the waste heat of the working fluid from being used effectively. In hydraulic retarder cooling system based on the Organic Rankine Cycle, the organic working fluid first transfers heat with the hydraulic retarder working fluid in Rankine cycle, and then outputs power through expansion machine. It can both reduce heat load of the engine cooling system, and enhance thermal stability of the hydraulic retarder while recovering and utilizing braking energy. First of all, according to the target vehicle model, hydraulic retarder cooling system model based on Rankine cycle is established.
Technical Paper

Study on Commercial Vehicle ECR Thermal Management System

2016-09-18
2016-01-1935
With the continuous increasing requirements of commercial vehicle weight and speed on highway transportation, conventional friction brake is difficult to meet the braking performance. To ensure the driving safety of the vehicle in the hilly region, the eddy current retarder (ECR) has been widely used due to its fast response, lower prices and convenient installation. ECR brakes the vehicle through the electromagnetic force generated by the current, and converted vehicle mechanical energy into heat through magnetic field. Air cooling structure is often used in the traditional ECR and cooling performance is limited, which causes low braking torque, thermal recession, and low reliability and so on. The water jacket has been equipped outside the eddy current region in this study, and the electric ECR is cooled through the water circulating in the circuit, which prolongs its working time.
Technical Paper

The Shock Absorber of Energy Recovery Using Electrorheological Fluid

2012-04-16
2012-01-0981
When vehicle traveling on the bumpy road or vehicle acceleration and deceleration, which will cause the body vibration of vehicle, at the same time, a large part of energy would be absorbed by the shock absorber transforms the mechanical energy into heat energy dissipated. In order to recycle the energy of vibration and keep the stability of running car, this paper provides the shock absorber of energy recovery that recycling the energy dissipated from the traditional absorber. The shock absorber includes rod and rodless chamber cavity, the two parts contain oil outlet and oil inlet, which connected to a bridge type loop of hydraulic to make pulsating oil pressure towards one direction, when the shock absorber vibration causes pulsating oil pressure, it drives hydraulic pump operation. Because the output shaft of the hydraulic pump fixedly attached to the input shaft of generator, so the generator produces electricity for recycling energy[1].
Technical Paper

Post-Treatment of Anaerobically Digested Solid Waste in Long Term Space Missions

2006-07-17
2006-01-2258
Post-treatment of anaerobically digested residue produced during long term space missions was investigated. Solid waste was anaerobically digested by employing the SEBAC system. One of the goals of post-treatment step is to convert ammonia in the residue to nitrates via biological nitrification processes. It was found that anaerobically digested residue contained nitrifying microorganisms which could be activated by aeration. Without supplying any external nitrifying inoculum, nitrification was initiated within 2 days by continuously blowing air at 15 ml/min. The maximum rate was 0.78 mg /g dry weight /day. However, denitrification process occurred soon after nitrification and ∼ 50% of nitrate was denitrified. A modified system in which aeration was carried out by holding air within the reactor at a pressure of ∼ 10 psi yielded a higher initial specific nitrification rate of 1.7 mg/g dry weight/day. Moreover, nitrification was initiated within a day.
Technical Paper

The Modeling and Performance Analysis of the Retarder Thermal Management System

2012-09-24
2012-01-1929
In order to obtain the comprehensive evaluation of thermal management system for the retarder, the complete driveline thermal management model is built. The characteristic parameters for the thermal management system are determined and the hydromechanical characteristics for the retarder are fixed by the rig test. On the basis of the same whole vehicle driving cycle, comparing to the traditional mechanical-drive system, the independent-drive system makes the working temperature of the heat source more stable. Meanwhile the parasitic power caused by the radiator fan is decreased markedly on the condition that the heat reject requirement of the heat source is satisfied.
Technical Paper

Automated SEBAC-II Prototype Solid Waste Management System for Long Term Space Mission

2005-07-11
2005-01-3025
This paper reports on design improvements made to a full-scale prototype solid waste management system designed to support a 6-person crew on long-term space missions. The original system design is based on Sequential Batch Anaerobic Composting (SEBAC), a patented process for odorless bioconversion of organic solid wastes to methane and compost by anaerobic digestion. The system consists of five reactors and two gas-liquid separators designed for operation under closed conditions in micro-gravity. During any week of operation, one reactor is being used for feed collection and compaction, three for stage-wise anaerobic composting, and one for post-treatment by aerobic stabilization while simultaneously serving as a bio-filter in the pretreatment of cabin air within the air revitalization subsystem. Previous work resulted in preliminary operating performance data that revealed the need for further design improvements [1].
Technical Paper

Calibration of Condensation Particle Counters

2005-04-11
2005-01-0189
Condensation particle counters (CPCs) have been used extensively during the past decade to measure the particle number concentration and, as part of a scanning mobility particle sizer (SMPS™) spectrometer, the size distribution of ultrafine and fine particle emissions from a wide range of spark ignition and diesel engines (Bischof and Horn 1999). This paper illustrates a method of calibrating the CPC particle counting efficiency, determination of the smallest particle size detection limit, and particle concentration linearity, by generating ultrafine particles with a novel, commercially available electrospray aerosol generator and using a sensitive aerosol electrometer as the traceable reference. The counting efficiencies of several TSI model 3010 CPCs were calibrated against the electrometer using monodisperse particles in the size range of 4.5 to 95 nm. Results from the tests show that the counting efficiencies of the CPCs are in close agreement with each other.
Technical Paper

Characteristics of Sub/Supercritical Gasoline and Iso-Octane Jets in High Temperature Environment

2019-04-02
2019-01-0289
Based on the temperature and pressure in the cylinder of GDI (Gasoline Direct Injection) engines under the common operating conditions, jets´ characteristics of gasoline and iso-octane at different fuel temperatures under the high ambient temperature were studied by means of high-speed photography and striation method. It is found that the supercritical gasoline jet shows the morphological collapse of jet center and the protrusion of the front surface, but the iso-octane jet doesn´t. Meanwhile, as the fuel temperature rises, the flash boiling and the interference between adjacent plumes affect the gasoline jet, and cause the center of the jet to form a high-speed and low-pressure zone, hence the air entrainment in this region contributes to the collapse of jets. The collapse and convergence of jets´ morphology are the main reasons for the change of penetration and cone angle.
Technical Paper

Analysis of Hydraulic Retarder Air-Friction Characteristics

2014-09-28
2014-01-2504
The retarder is an important auxiliary braking device of heavy vehicles. However, the stirring air in the working wheels of the idle retarder would cause the transmission loss when the vehicle is traveling in non-braking state [1]. For certain driving conditions, the air-friction characteristics in the working wheels of the idle retarder are analyzed first. Then the relationship between the air density and the torque produced by stirring air is studied. The thermal characteristics of the retarder in the idle condition are also concerned according to the energy flow and heat transfer. Meanwhile, the increased transmission loss caused by the rising temperature of the stirring air and its inference on the transmission stability are also studied. Finally, the optimal range of air vacuum degrees in the working wheel of the idle retarder is determined and the evaluations for the air-friction and the heat transfer characteristics are given for the vacuum degrees.
Technical Paper

The Selection of Working Fluid Used in the Organic Rankine Cycle System for Hydraulic Retarder

2016-04-05
2016-01-0187
With the improvement of occupants’ awareness on the driving safety, hydraulic retarder applications increase quickly. The traditional hydraulic retarder, on the one hand, exhausts the waste heat of transmission oil by the engine cooling system; on the other hand, the engine power should be consumed to drive the water pump and the engine cooling fan for maintaining the normal operation of the auxiliary braking system. In this study, the Organic Rankine Cycle (ORC) instead of the traditional hydraulic retarder water-cooling system is applied to achieve the effective temperature control of the hydraulic retarder, while the waste heat of transmission oil could be recovered for saving vehicle energy consumption. The ORC fluid selection needs comprehensive consideration for the net power of the ORC and the optimal temperature range of the retarder transmission oil at both the inlet and outlet end, which is the key issue to ensure the stability and efficiency of the ORC system performance.
Technical Paper

Thermal Stability Research of Vehicle Exhaust Waste-Heat Recovery System with Intermediate Medium

2016-04-05
2016-01-0228
Vehicle exhaust waste-heat recovery with thermoelectric power generators can improve energy efficiency, as well as vehicle fuel economy. In the conventional structure, the hot-end of thermoelectric module is directly connected with the outer wall of the exhaust pipe, while the cold-end is connected with the water pipe’s outer wall of the vehicle engine cooling cycle. However, the variety of vehicle engine operating conditions leads to the instability of the hot-end temperature, which will reduce the generating efficiency of the thermoelectric modules and also shorten its service life. This research is on the basis of constructing a heat transfer oil circulation, and to study the action principles and implementation methods of it.
Technical Paper

Multidisciplinary Design Optimization of BEV Body Structure

2015-01-14
2015-26-0229
Blade Electric Vehicle (BEV) with a light body plays an important role in saving the energy and reducing the exhaust emission. However, reducing the body weight need to meet the heterogeneous attributes such as structural, safety and NVH (Noise, Vibration and Harshness) performance. With the rapid development of finite element (FE) analysis technology, simulation analysis is widely used for researching the complex engineering design problem. Multidisciplinary Design Optimization (MDO) of a BEV body is a challenging but meaningful task in the automotive lightweight. In present research, the MDO is introduced to optimize a BEV Body-in-White (BIW).
Technical Paper

Integrated Cooling Evaporation System for the Hydraulic Retarder

2015-04-14
2015-01-1612
The hydraulic retarder is a significant auxiliary braking device [1] for the heavy duty vehicle. Traditionally, cooling circulatory system of the hydraulic retarder was coupled with the engine cooling system [2], and the thermal energy of the transmission medium would be cooled by the engine radiator ultimately. For this scheme, radiator's spare heat removal capacity could be fully utilized whereas the cooling system is very complicated and is hard to maintain. Furthermore, the corresponding of thermal management system lags behind the power change of the retarder. In this research, integrated cooling evaporation system is developed for the hydraulic retarder, which makes the cooling water contact with the transmission medium through the stator wall, so that it can rapidly response to the thermal variation of the retarder, keep the stability of the oil temperature and meanwhile reduce the risk of cooling medium leakage.
Technical Paper

Study of Energy Recovery System Based on Organic Rankine Cycle for Hydraulic Retarder

2016-04-05
2016-01-0239
The hydraulic retarder is an auxiliary braking device used in heavy duty vehicle. It generates braking forceby liquid damping effect and makes inertial energy into thermal energy of the transmission medium when the vehicleis in thedownhill. The traditional thermal management system of the hydraulic retarder dissipates the heat of transmission medium out of the vehicle directly, which causes a big waste of energy, meanwhilethe thermal management system components need to consume engine power. This study applies organic Rankine cycle (ORC)cooling system to meet the high power cooling requirements of the hydraulic retarder and recover waste heat energy from the transmission medium at the same time and then supply energy to the thermal management system, which could save the parasitic power of the engine and improve the comprehensive energy utilization ratio of the vehicle.
X