Refine Your Search

Topic

Author

Affiliation

Search Results

Journal Article

Development and Advances of a V-Flow FC Stack for FCX Clarity

2009-04-20
2009-01-1010
Honda has succeeded in developing the new fuel cell (FC) vehicle designed into a dynamic, full-cabin sedan, the FCX Clarity, originating from the new V Flow FC platform. The key technology is V Flow FC Stack, featuring V Flow cell structure in which the fuel gases run from top to bottom vertically through the wave flow-channels. According to this unique structure, the fuel cell stack sits longitudinally along the center tunnel, and a Vertebral layout has emerged. The Vertebral layout results in Volume efficient package and low-floor platform. The V Flow FC stack has achieved a high output of 100kW and improved the output density with 50% by volume and 67% by mass, compared to the previous 2005 model. The V Flow cell structure utilizes gravity for water drainage and reduces the channel depth creating thinner cells. The wave-shaped vertical gas flow channel provides horizontal and more efficient coolant flow distribution allowing the reduction of the number of cooling layer.
Journal Article

Active Heat Sink for Automotive Electronics

2009-04-20
2009-01-0965
This paper reports an active heat sink (AHS) that allows high-density electronic components to operate at a stable temperature over a broad range of ambient conditions. AHS receives heat at high flux and transfers it at reduced flux to environment, coolant fluid (e.g., air or engine coolant), or structures. Temperature of the heat load can be controlled electronically. Target applications for AHS include thermal management of the new class of high-power electronics being developed for electric hybrid vehicles. AHS also enables precise control over junction temperature (and, thus, light color) of high-power light-emitting diodes (LED) used for solid-state headlights and allows for compact air-cooled heat sinks. Depending on the configuration, AHS thermal resistance can be as low as 0.1 degC/W. AHS physics, engineering design, and performance simulations are presented.
Journal Article

Hollow Fiber Space Suit Water Membrane Evaporator Development for Lunar Missions

2009-07-12
2009-01-2371
The Space Suit Water Membrane Evaporator (SWME) is a baseline heat rejection technology that was selected to develop the Constellation Program lunar suit. The Hollow Fiber (HoFi) SWME is being considered for service in the Constellation Space Suit Element Portable Life Support Subsystem to provide cooling to the thermal loop via water evaporation to the vacuum of space. Previous work [1] described the test methodology and planning that are entailed in comparing the test performance of three commercially available HoFi materials as alternatives to the sheet membrane prototype for SWME: (1) porous hydrophobic polypropylene, (2) porous hydrophobic polysulfone, and (3) ion exchange through nonporous hydrophilic-modified Nafion®.
Journal Article

Mars Science Laboratory Mechanically Pumped Fluid Loop for Thermal Control - Design, Implementation, and Testing

2009-07-12
2009-01-2437
The Mars Science Laboratory (MSL) mission to land a large rover on Mars is being prepared for Launch in 2011. A Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) on the rover provides an electrical power of 110 W for use in the rover and the science payload. Unlike the solar arrays, MMRTG provides a constant electrical power during both day and night for all seasons (year around) and latitudes. The MMRTG dissipates about 2000 W of waste heat to produce the desired electrical power. One of the challenges for MSL Rover is the thermal management of the large amount of MMRTG waste heat. During operations on the surface of Mars this heat can be harnessed to maintain the rover and the science payload within their allowable limits during nights and winters without the use of electrical survival heaters. A mechanically pumped fluid loop heat rejection and recovery system (HRS) is used to pick up some of this waste heat and supply it to the rover and payload.
Journal Article

Flying Test Bed Performance Testing of High-Bypass-Ratio Turbofans

2009-11-10
2009-01-3133
The commercial turbofan trend of increasing bypass ratio and decreasing fan pressure ratio has seen its latest market entry in Pratt & Whitney's PurePower™ product line, which will power regional aircraft for the Bombardier and Mitsubishi corporations, starting in 2013. The high-bypass-ratio, low-fan-pressure-ratio trend, which is aimed at diminishing noise while increasing propulsive efficiency, combines with contemporary business factors including the escalating cost of testing and limited availability of simulated altitude test sites to pose formidable challenges for engine certification and performance validation. Most fundamentally, high bypass ratio and low fan pressure ratio drive increased gross-to-net thrust ratio and decreased fan temperature rise, magnifying by a factor of two or more the sensitivity of in-flight thrust and low spool efficiency to errors of measurement and assumption, i.e., physical modeling.
Journal Article

Unregulated Harmful Substances in Exhaust Gas from Diesel Engines

2009-06-15
2009-01-1870
The volatile organic compounds (VOC) from diesel engines, including formaldehyde and benzene, are concerned and remain as unregulated harmful substances. The substances are positively correlated with THC emissions, but the VOC and aldehyde compounds at light load or idling conditions are more significant than THC. When coolant temperatures are low at light loads, there are notable increases in formaldehyde and acetaldehyde, and with lower coolant temperatures the increase in aldehydes is more significant than the increase in THC. When using ultra high EGR so that the intake oxygen content decreases below 10%, formaldehyde, acetaldehyde, benzene, and 1,3-butadiene increase significantly while smokeless and ultra low Nox combustion is possible.
Journal Article

Practical Approach to Develop Low Cost, Energy Efficient Cabin Heating for Extreme Cold Operating Environment

2011-04-12
2011-01-0132
In cold climatic regions (25°C below zero) thermal comfort inside vehicle cabin plays a vital role for safety of driver and crew members. This comfortable and safe environment can be achieved either by utilizing available heat of engine coolant in conjunction with optimized in cab air circulation or by deploying more costly options such as auxiliary heaters, e.g., Fuel Fired, Positive Temperature Coefficient heaters. The typical vehicle cabin heating system effectiveness depends on optimized warm/hot air discharge through instrument panel and foot vents, air directivity to occupant's chest and foot zones and overall air flow distribution inside the vehicle cabin. On engine side it depends on engine coolant warm up and flow rate, coolant pipe routing, coolant leakage through engine thermostat and heater core construction and capacity.
Journal Article

Automotive Brake Hose Fluid Consumption Characteristics and Its Effects on Brake System Pedal Feel

2010-04-12
2010-01-0082
During the automotive brake system design and development process, a large number of performance characteristics must be comprehended, assessed, and balanced against each other and, at times, competing performance objectives for the vehicle under development. One area in brake development that is critical to customer acceptance due to its impact on a vehicle's perceived quality is brake pedal feel. While a number of papers have focused on the specification, quantification and modeling of brake pedal feel and the various subsystem characteristics that affect it, few papers have focused specifically on brake corner hoses and their effect on pedal feel, in particular, during race-track conditions. Specifically, the effects of brake hose fluid consumption pedal travel and brake system response is not well comprehended during the brake development process.
Journal Article

Prediction of the Performance of the Engine Cooling Fan with CFD Simulation

2010-04-12
2010-01-0548
The technology concerning thermo and fluid dynamics is one of the important fields which have made great progress along with rapid advance in computational resources. Especially, the CFD technology has been proved as successful contribution to the development of the engine cooling system. Therefore, this technology is widely used at early phase of the vehicle development. However, a serious problem has been remained that it does not always give practical precision. Particularly, the cooling fan is one of the primary components in the cooling system to determine the performance, while practical calculation method without depending on large resources has not established.
Journal Article

Contact Fatigue Wear Evaluation of Thrust Rolling Bearings Lubricated With Greases With Molybdenum Disulfide Or Graphite

2010-05-05
2010-01-1546
The wear of thrust 51100 rolling bearings was investigated and their dissipative responses in a bench test rig were associated to their heating, elastic energy of mechanical vibration and Sound Pressure Level [dB], regarding two greases, both from the same supplier, being one with graphite and the other with Molybdenum Disulfide. The samples were commercially acquired and submitted to a normal load of 450±5N and 3100±30 CPM, determined after the screening tests. Four variables were measured: temperature [K], electrical power [W], global velocity vibration [mm/s] and Sound Pressure Level [dB]. After 106 cycles, the tracks were analyzed by Optical Microscopy. The bearings lubricated with the grease with graphite showed different responses in relation to the ones lubricated with MoS2 thrust bearings. The signal of the signatures and the damage morphology are presented and discussed.
Journal Article

Thermal Management of Vehicular Payloads Using Nanofluid Augmented Coolant Rail - Modeling and Analysis

2013-04-08
2013-01-1641
Various payloads, such as electronic systems, have become an integral part of modern military ground vehicles. These payloads often feature high thermal density that need to be effectively managed, especially under demanding operating conditions, to maintain system reliability. This paper describes the modeling and analysis of a nanofluid augmented coolant rail combined with thermoelectric devices to address the cooling challenges posed by these payloads. A sensitivity analysis has been performed to investigate the nanoparticle enhancement model. Numerical results obtained show that the convective heat transfer coefficient can be enhanced by up to 16% with the augmentation of nanoparticles into the base fluid. The results also show that the peak computer temperature is rather insensitive to the complexity of the model used and that the proposed system provides cooling performance which would not be possible with traditional air-cooled heat sinks.
Journal Article

CO2 Reduction Potential through Improved Mechanical Efficiency of the Internal Combustion Engine: Technology Survey and Cost-Benefit Analysis

2013-04-08
2013-01-1740
The need for significant reduction of fuel consumption and CO₂ emissions has become the major driver for development of new vehicle powertrains today. For the medium term, the majority of new vehicles will retain an internal combustion engine (ICE) in some form. The ICE may be the sole prime mover, part of a hybrid powertrain or even a range extender; in every case potential still exists for improvement in mechanical efficiency of the engine itself, through reduction of friction and of parasitic losses for auxiliary components. A comprehensive approach to mechanical efficiency starts with an analysis of the main contributions to engine friction, based on a measurement database of a wide range of production engines. Thus the areas with the highest potential for improvement are identified. For each area, different measures for friction reduction may be applicable with differing benefits.
Journal Article

Drivetrain Energy Distribution and Losses from Fuel to Wheel

2013-11-20
2013-01-9118
Depending on a vehicles drive cycle, an improvement of the overall drivetrain efficiency does not necessarily have to go along with an improvement of its mileage. In here the ratio of energy to overcome rolling resistance, aerodynamic drag, acceleration and energy wasted directly in wheel brakes is responsible for potentially differing trends. A detailed knowledge of energy flows, sources and sinks makes up a substantial step into optimizing any drive train. Most fuel energy leaves the drivetrain via exhaust pipes. Next to usable mechanical energy, a big amount is spent to heat up the system directly or to overcome drive train friction, which is converted into heat to warm up the system additionally. An in depth quantification of the most important energy flows for an upper middle-sized class gasoline powered drive train is given as results of warm-up cycle simulations.
Journal Article

Integrated Low Temperature Cooling System Development in Turbo Charged Vehicle Application

2014-04-01
2014-01-0638
The Low Temperature Cooling (LTC) system is commonly developed for secondary cooling function requirements, such as forced induction air cooling, and HEV power electronics module cooling. The large heat transfer capacity of coolant allows for very compact water-cooled heat exchangers to be installed remotely for better underhood aerodynamic characteristics and more compact packaging design. An integrated LTC loop developed on a Hyundai 2.0L Turbo Charged vehicle extends a traditional WCAC (Water-cooled charged air cooler) application to include a water-cooled condenser (WCOND) module. Unlike other published LTC system design approaches, this research project emphasizes underhood airflow improvement strategy and focuses on heat transfer efficiency. This paper discusses the integrated LTC loop configuration, Low Temperature Radiator (LTR) design, coolant flow control, and others.
Journal Article

Experimental Investigation of Heat Transfer Rate and Pressure Drop through Angled Compact Heat Exchangers Relative to the Incoming Airflow

2014-09-30
2014-01-2337
This paper presents pressure drops and heat transfer rates for compact heat exchangers, where the heat exchangers are angled 90°, 60°, 30° and 10° relative to the incoming airflow. The investigation is based on three heat exchangers with thicknesses of 19mm and 52mm. Each heat exchanger was mounted in a duct, where it was tested for thermal and isothermal conditions. The inlet temperature of the coolant was defined to two temperatures; ambient temperature and 90°C. For the ambient cases the coolant had the same temperature as the surrounding air, these tests were performed for five airflow rates. When the coolant had a temperature of 90°C a combination of five coolant flow rates and five airflow rates were tested. The test set-up was defined as having a constant cross-section area for 90°, 60° and 30° angles, resulting in a larger core area and a lower airspeed through the core, for a more inclined heat exchanger.
Journal Article

A New Tool to Perform Global Energy Balances in DI Diesel Engines

2014-04-01
2014-01-0665
The generalization of exhaust aftertreatment systems along with the growing awareness about climate change is leading to an increasing importance of the efficiency over other criteria during the design of reciprocating engines. Using experimental and theoretical tools to perform detailed global energy balance (GEB) of the engine is a key issue for assessing the potential of different strategies to reduce consumption. With the objective of improving the analysis of GEB, this paper describes a tool that allows calculating the detailed internal repartition of the fuel energy in DI Diesel engines. Starting from the instantaneous in-cylinder pressure, the tool is able to describe the different energy paths thanks to specific submodels for all the relevant subsystems.
Journal Article

Proper Orthogonal Decomposition Analysis of Flow Structures Generated around Engine Cooling Fan

2014-04-01
2014-01-0667
A cooling fan is one of the primary components affecting the cooling performance of an engine cooling system. In recent years, with the increase in electric vehicles (EVs) and hybrid vehicles (HVs), the cooling performance and noise level of the cooling fan have become very important. Thus, the development of a low-noise fan with the same cooling performance is urgently required. To address this issue, it is critical to find the relation between the performance of the fan and the flow structures generated around it, which is discussed in the present paper. Specifically, a computational method is employed that uses unsteady Reynolds-averaged Navier-Stokes (URANS) coupling with a sliding mesh (SLM). Measurements of the P-Q (Pressure gain-Flow rate) characteristics are performed to validate the predictive accuracy of the simulation.
Journal Article

Design for Six Sigma (DFSS) for Optimization of Automotive Heat Exchanger and Underhood Air Temperature

2014-04-01
2014-01-0729
In this paper a design methodology for automotive heat exchangers has been applied which brings robustness into the design process and helps to optimize the design goals: as to maintain an optimal coolant temperature and to limit the vehicle underhood air temperature within a tolerable limit. The most influential design factors for the heat exchangers which affect the goals have been identified with that process. The paper summarizes the optimization steps necessary to meet the optimal functional goals for the vehicle as mentioned above. Taguchi's [1] Design for Six Sigma (DFSS) methods have been employed to conduct this analysis in a robust way.
Journal Article

Under-Hood Air Flow Evaluation of Pedestrian-Friendly Front-End Style Using CFD Simulation

2014-04-01
2014-01-0762
The efficiency of the vehicle cooling system strongly depends on the air flow through the radiator core. The flow through the radiator core in turn depends on other panels that are in the vicinity of the radiator. In this study, the effect of geometrical change at vehicle front-end including the whole bonnet, grille and bumper area is investigated by means of Computational Fluid Dynamics (CFD). Numerical modeling is carried out by means of CAE tools. Simulations are performed for maximum power and maximum torque conditions, monitoring the mass flow rate through the radiator core and velocity contribution over the radiator face. To the velocity field of the airflow, the heat exchangers are represented as porous media and fan module is modeled utilizing Multiple Reference Frame (MRF) approach. The validity of the developed simulation capability is tested by successful comparison with the available experimental data for the base model at the given operating conditions.
Journal Article

Efficient, Active Radiator-Cooling System

2013-05-15
2013-01-9017
A new concept for an efficient radiator-cooling system is presented for reducing the size or increasing the cooling capacity of vehicle coolant radiators. Under certain conditions, the system employs active evaporative cooling in addition to conventional finned air cooling. In this regard, it is a hybrid radiator-cooling system comprised of the combination of conventional air-side finned surface cooling and active evaporative water cooling. The air-side finned surface is sized to transfer required heat under all driving conditions except for the most severe. In the later case, evaporative cooling is used in addition to the conventional air-side finned surface cooling. Together the two systems transfer the required heat under all driving conditions. However, under most driving conditions, only the air-side finned surface cooling is required. Consequently, the finned surface may be smaller than in conventional radiators that utilize air-side finned surface cooling exclusively.
X