Refine Your Search

Search Results

Viewing 1 to 7 of 7
Standard

Jet Blast Windshield Rain Removal Systems for Commercial Transport Aircraft

1997-10-01
HISTORICAL
AIR805B
The purpose of this information report is to present factors which affect the design and development of jet blast windshield rain removal systems for commercial transport aircraft. A satisfactory analytical approach to the design of these systems has not yet been developed. Although detailed performance data are available for some test configurations, rain removal systems will generally be unique to specific aircraft. This, then, requires a preliminary design for the system based on available empirical data to be followed with an extensive laboratory development program.
Standard

Environmental Control for Civil Supersonic Transport

1994-12-01
HISTORICAL
AIR746B
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

Environmental Control for Civil Supersonic Transport

2011-08-10
CURRENT
AIR746C
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

Guide for Qualification Testing of Aircraft Air Valves

1997-03-01
HISTORICAL
ARP986C
This Aerospace Recommended Practice (ARP) defines tests to be performed on hydraulically, electrically, pneumatically, and mechanically actuated air valves. They may be further defined as those valves that function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions in order to maintain a calibrated duct air condition (e.g., air flow, air pressure, air temperature, air pressure ratio, or air shutoff).
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1990-02-28
HISTORICAL
ARP986B
This Aerospace Recommended Practice (ARP) defines tests to be performed on hydraulically, electrically, pneumatically, and mechanically actuated air valves. They may be further defined as those valves that function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions in order to maintain a calibrated duct air condition (e.g., air flow, air pressure, air temperature, air pressure ratio, or air shutoff).
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1982-10-01
HISTORICAL
ARP986A
This document defines tests to be performed on electrically, pneumatically, and mechanically actuated (regulating, modulating, and shutoff) air valves. The valves may be further defined as those which function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions to maintain a calibrated duct air condition (i.e., air flow, air pressure, air temperature, air pressure ratio, etc.). The requirements of this document should govern for all qualification tests unless different requirements are established by the detail specifications.
X