Refine Your Search

Search Results

Viewing 1 to 5 of 5
Standard

Characterization, Conducted Immunity

2018-06-12
CURRENT
J2628_201806
The methods included in this document are: a Voltage-Temperature Design Margins. b Voltage Interruptions and Transients. c Voltage Dropouts and Dips. d Current Draw Under a Number of Conditions. e Switch Input Noise These methods are best applied during the Development stage but can be used at all stages (e.g., Pre-Qualification, Qualification or Conformity).
Standard

Characterization, Conducted Immunity

2013-07-16
HISTORICAL
J2628_201307
The methods included in this document are: a Voltage-Temperature Design Margins. b Voltage Interruptions and Transients. c Voltage Dropouts and Dips. d Current Draw Under a Number of Conditions. e Switch Input Noise These methods are best applied during the Development stage but can be used at all stages (e.g., Pre-Qualification, Qualification or Conformity).
Standard

Immunity to Conducted Transients on Power Leads

2018-12-10
CURRENT
J1113/11_201812
This SAE Standard defines methods and apparatus to evaluate electronic devices for immunity to potential interference from conducted transients along battery feed or switched ignition inputs. Test apparatus specifications outlined in this procedure were developed for components installed in vehicles with 12-V systems (passenger cars and light trucks, 12-V heavy-duty trucks, and vehicles with 24-V systems). Presently, it is not intended for use on other input/output (I/O) lines of the device under test (DUT).
Standard

Immunity to Conducted Transients on Power Leads

2012-01-30
HISTORICAL
J1113/11_201201
This SAE Standard defines methods and apparatus to evaluate electronic devices for immunity to potential interference from conducted transients along battery feed or switched ignition inputs. Test apparatus specifications outlined in this procedure were developed for components installed in vehicles with 12-V systems (passenger cars and light trucks, 12-V heavy-duty trucks, and vehicles with 24-V systems). Presently, it is not intended for use on other input/output (I/O) lines of the device under test (DUT).
Standard

Immunity to Conducted Transients on Power Leads

2017-06-13
HISTORICAL
J1113/11_201706
This SAE Standard defines methods and apparatus to evaluate electronic devices for immunity to potential interference from conducted transients along battery feed or switched ignition inputs. Test apparatus specifications outlined in this procedure were developed for components installed in vehicles with 12-V systems (passenger cars and light trucks, 12-V heavy-duty trucks, and vehicles with 24-V systems). Presently, it is not intended for use on other input/output (I/O) lines of the device under test (DUT).