Training / Education

Introduction to Highly Automated Vehicles

2019-04-08
Every year, the U.S. experiences more than 32,000 traffic deaths and over 3.8 million crash injuries. While the trend in traffic deaths has been downward for the past decade, most of this reduction has been the result of optimizing passive occupant crash protection systems such as seatbelts and airbags. Advanced driver assistance systems (ADAS) now offer the potential to significantly reduce or eliminate most vehicle crashes by perceiving a dangerous situation before the crash has occurred and taking action to avoid or mitigate the crash.
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2011-02-04
CURRENT
J2772_201102
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC-Module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 [CO2] and R-1234yf [HFO-1234yf], but the general techniques described here can be used for other refrigerants as well.
Standard

Top Speed Test Procedure for Electric Motorcycles

2014-02-21
CURRENT
J3007_201402
This SAE Recommended Practice incorporates a track-based test procedure that produces a representative value for vehicle top speed when operating on a level paved road with a fully charged battery.
Standard

Air Dryer Test Procedure

2012-11-09
CURRENT
J2384_201211
This SAE Recommended Practice establishes uniform Test Procedures for desiccant Air Dryers used in vehicles with compressed air systems per SAE J2383. Continuous flow desiccant Air Dryers are excluded from the scope of this document.
Collection

Autonomous Systems, 2017

2017-03-28
With a mandate in Europe for autonomous emergency braking systems, there is a development happening with radar and camera based systems to do collision mitigation. The challenges include robust object tracking, stationary object detection, reactions for false positives, etc. The developments and challenges in the collision mitigation technology are included in this collection.
Standard

SAE MANUAL ON BLAST CLEANING

1968-06-01
CURRENT
J792A_196806
Blast cleaning may be defined as a secondary manufacturing process in which a suitable stream of solid particles is propelled with sufficient velocity against a work surface to cause a cleaning or abrading action when it comes in contact with the workpiece. As indicated in the definition, blast cleaning may be employed for a variety of purposes. Ordinarily, it is considered as a method for removing sand from castings, burrs or scale from forgings, mill products, or heat treated parts; to promote machinability, and to minimize the possibility of interference in actual operation. In addition to this use, blast cleaning also produces an excellent surface for industrial coatings. All these objectives are often accomplished in the one operation.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2015-09-22
CURRENT
J968/2_201509
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2002-12-20
HISTORICAL
J968/2_200212
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Standard

Brake System Road Test Code - Passenger Car and Light-Duty Truck

2013-03-28
CURRENT
J843_201303
This SAE Recommended Practice establishes a uniform procedure for the level road test of the brake systems of new light-duty trucks and new multipurpose passenger vehicles1 up to and including 2700 kg (6000 lb) GVW and all classes of new passenger cars.