AIRCRAFT ELECTRICAL HEATING SYSTEMS

1965-01-10
HISTORICAL
AIR860
It is intended that the scope of this information report be limited to electrical heating of passenger, crew, and cargo compartments only.
Standard

Aircraft Electrical Heating Systems

2000-06-01
HISTORICAL
AIR860A
It is intended that the scope of this information report be limited to electrical heating of passenger, crew, and cargo compartments only. No attempt has been made to develop the complete electrical circuitry associated with the electrical heating components; however, the electrical circuitry required for heating component operation, safety, and monitoring will be included as available. Specific design information is given for various modern aircraft utilizing electrical heating. Each aircraft discussed will be identified by alphabetical letter designation and included in the appropriate appendix.
Standard

Aircraft Electrical Heating Systems

2011-10-17
CURRENT
AIR860B
It is intended that the scope of this information report be limited to electrical heating of passenger, crew, and cargo compartments only. No attempt has been made to develop the complete electrical circuitry associated with the electrical heating components; however, the electrical circuitry required for heating component operation, safety, and monitoring will be included as available. Specific design information is given for various modern aircraft utilizing electrical heating. Each aircraft discussed will be identified by alphabetical letter designation and included in the appropriate appendix.
Standard

AIR CONDITIONING OF AIRCRAFT CARGO

1978-07-01
HISTORICAL
AIR806A
The report presents air conditioning data for aircraft cargo which is affected by temperature, humidity, ventilation rate and atmospheric pressure. The major emphasis is on conditioning of perishable products and warm-blooded animals. The report also covers topics peculiar to cargo aircraft or which are related to the handling of cargo.
Standard

Air Conditioning of Aircraft Cargo

1997-10-01
CURRENT
AIR806B
The report presents air conditioning data for aircraft cargo which is affected by temperature, humidity, ventilation rate and atmospheric pressure. The major emphasis is on conditioning of perishable products and warm-blooded animals. The report also covers topics peculiar to cargo aircraft or which are related to the handling of cargo.
Standard

HEAT TRANSFER PROBLEMS ASSOCIATED WITH AEROSPACE VEHICLES

1978-04-01
CURRENT
AIR732
The discipline of heat transfer concerns itself basically with the three modes of transferring thermal energy (convection, conduction, and radiation) and their inter-relations. In any phase of aerospace vehicle design, the importance of any of these basic modes will vary depending upon the natural and induced environment the mission imposes as well as the vehicle configuration.
Standard

Environmental Control for Civil Supersonic Transport

1994-12-01
HISTORICAL
AIR746B
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

Environmental Control for Civil Supersonic Transport

2011-08-10
CURRENT
AIR746C
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

OZONE PROBLEMS IN HIGH ALTITUDE AIRCRAFT

1996-07-01
HISTORICAL
AIR910A
The purpose of this report is to provide information on ozone and its control in high altitude aircraft environmental systems. Sources of this information are listed in the selected bibliography appearing at the end of this report, to which references are made throughout.
Standard

Electrical and Electronic Equipment Cooling in Commercial Transports

1992-09-01
CURRENT
AIR64B
This document considers the cooling of equipment installed in equipment centers, which usually consist of rack-mounted equipment and panel mounted equipment in the flight deck. In instances where these two locations result in different requirements, these are identified. For purposes of this document, the cooled equipment is referred to generally as E/E equipment, denoting that both electrical and electronic equipment is considered, or as an E/E equipment line-replaceable-unit (LRU). The majority of cooled equipment takes the form of LRUs. This document primarily relates to E/E equipment which is designed to use forced air cooling in order to maintain the equipment within acceptable environmental limits, in order to maintain equipment operating performance (within acceptable tolerances), and to maintain reliability. Cooling may be applied internally or externally to the case of the item of E/E equipment.
Standard

AIRCRAFT HUMIDIFICATION

1982-04-30
HISTORICAL
AIR1609
This report covers the design parameters for various methods of humidification applicable to aircraft, the physiological aspects of low humidities, the possible benefits of controlling cabin humidity, the penalties associated with humidification, and the problems which must be solved for practical aircraft humidification systems. The design information is applicable to commercial and military aircraft. The physiological aspects cover all aircraft environmental control applications.
Standard

Aircraft Humidification

2005-03-21
CURRENT
AIR1609A
This SAE Aerospace Information Report (AIR) covers the design parameters for various methods of humidification applicable to aircraft, the physiological aspects of low humidities, the possible benefits of controlling cabin humidity, the penalties associated with humidification, and the problems which must be solved for practical aircraft humidification systems. The design information is applicable to commercial and military aircraft. The physiological aspects cover all aircraft environmental control applications.
Standard

Cooling of Military Avionic Equipment

2005-02-09
CURRENT
AIR1277B
This SAE Aerospace Information Report (AIR) contains information on the thermal design requirements of airborne avionic systems used in military airborne applications. Methods are explored which are commonly used to provide thermal control of avionic systems. Both air and liquid cooled systems are discussed.
Standard

COOLING OF MODERN AIRBORNE ELECTRONIC EQUIPMENT

1976-05-01
HISTORICAL
AIR1277
This document contains information on the cooling of modern airborne electronics, emphasizing the use of a heat exchange surface which separates coolant and component. It supplements the information contained in AIR 64 for the draw through method and in AIR 728 for high Mach Number aircraft. Report contents include basic methods, characteristics of coolants, application inside and outside of the "black box" use of thermostatic controls to improve reliability and system design. Characteristics of typical cooling components are treated sufficiently to permit selection and to estimate size and weight. While emphasis is placed herein on equipment cooling, section 9 dealing with thermal control of the environment, reminds the reader that some equipment will require heating for start up from a cold condition or as a means to control temperature within narrow limits (e.g. in a crystal oven). Property data and constants are also tabulated.
Standard

FAULT ISOLATION IN ENVIRONMENTAL CONTROL SYSTEMS OF COMMERCIAL TRANSPORTS

1977-08-01
HISTORICAL
AIR1266
This AIR outlines concepts for the design and use of fault isolation equipment that have general application. However, the specific concern applies only to use with Environmental Control Systems in commercial transports. In particular, automatic Built In Test Equipment (BITE) with manual initiation and software programs are covered as systems already in use.
Standard

Fault Isolation in Environmental Control Systems of Commercial Transports

1993-11-01
CURRENT
AIR1266A
This SAE Aerospace Information Report (AIR) outlines concepts for the design and use of fault isolation equipment that have general application. The specific focus is on fault isolation of environmental control systems (ECS) in commercial transports. Presented are general fault isolation purposes, design principles, and demonstration of compliance criteria. These are followed by three design examples to aid in understanding the design principles. Future trends in built-in-test-equipment (BITE) design are discussed, some of which represent concepts already being implemented on new equipment.
Standard

ANIMAL ENVIRONMENT IN CARGO COMPARTMENTS

1985-10-01
HISTORICAL
AIR1600
The environmental factors of prime importance in the transport of animals in aircraft are air temperature, humidity and carbon dioxide concentration, and of course space (or volume) limitations. Secondary factors are air velocity, noise, lighting, etc. Pressure is not addressed herein as pressure levels and rates of change are totally dictated by human occupancy requirements. Some basic governmental documents, such as References 1, 2 and 3, define overall requirements for animal transportation, but with very limited data on environmental requirements. Reference 4 gives some airplane characteristics measured during animal transportation from the USA to foreign destinations. Temperature and humidity profiles are indicative of airplane characteristics. This report presents information on the temperature, humidity, ventilation, and carbon dioxide limitations and the metabolic heat release rates for animals which will allow the determination of the environment required by the animals.