Introduction to Commercial and Off-Road Vehicle Cooling Airflow Systems

Vehicle functional requirements, emission regulations, and thermal limits all have a direct impact on the design of a powertrain cooling airflow system. Given the expected increase in emission-related heat rejection, suppliers and vehicle manufacturers must work together as partners in the design, selection, and packaging of cooling system components. An understanding and appreciation of airflow integration issues and vehicle-level trade-offs that effect system performance are important to the team effort. The severe duty cycles, minimal ram air, and sometimes unconventional package layouts present unique challenges.
Training / Education

Fluids for Aerospace Hydraulic Systems

This four-hour short course provides an introduction to fluids for aerospace hydraulic systems. Topics covered include an introduction to basics fluid properties, rheology, tribology, and fluid product development. In addition, the history and performance of different classes of fluids are discussed in detail, and specific failure modes such as erosion and sludge formation will be described. Along with an introduction to fluid degradation, information on used oil analysis test methods and interpretation will be provided.
Training / Education

Filtration and Contamination Control for Aerospace Hydraulic Systems

This four-hour short course provides an introduction to contamination control principles in aircraft hydraulic systems. Topics covered include an introduction to the types of contamination in aircraft hydraulic systems, contaminant measurement, and reporting methods. In addition, the impact of contamination on hydraulic components is discussed in detail. Along with an introduction to filtration mechanisms, information on testing, rating, and specifying filters will be provided.
Video

Neural Network-based Optimal Control for Advanced Vehicular Thermal Management Systems

2011-12-05
Advanced vehicular thermal management system can improve engine performance, minimize fuel consumption, and reduce emissions by harmoniously operating computer-controlled servomotor components. In this paper, a neural network-based optimal control strategy is proposed to regulate the engine temperature through the advanced cooling system. Presenter Asma Al Tamimi, Hashemite University
Video

Cooling Airflow System Modeling in CFD Using Assumption of Stationary Flow

2011-11-29
Today CFD is an important tool for engineers in the automotive industry who model and simulate fluid flow. For the complex field of Underhood Thermal Management, CFD has become a very important tool to engineer the cooling airflow process in the engine bay of vehicles. Presenter Peter Gullberg, Chalmers University of Technology
Video

High Speed Machining of CFRP Parts

2012-03-16
High Speed Machining of CFRP Parts Investigation of the influence of new geometries, cutting datas and coolant capabilities on the surface finish of CFRP parts. State of the art: Different CFRP grades and machining conditions make geometry adjustments to the tool necessary. Mechanical failures through machining operations can be avoided in most of the cases. New unidirectional CFRP grades and dry machining processes again lead to machining problems. This study investigates new geometries to avoid heat damage with dry maching and air coolant in case of unidirectional CFRP. With help of a thermo camera and the surface investigation with a scanning electron microscope, heat damage can be analysed and therefore new geometries can be developed and tested. Target is to develop a new multi purpose CFRP geometry to meet the requirements of the future. The reduction of different geometries used leads to major cost savings. Presenter Ingo von Puttkamer, Guhring oHG
Standard

Recommended Design and Test Requirements for Quantity Measuring Hydraulic Fuses

2018-11-07
WIP
ARP8450
1. SCOPE This Aerospace Recommended Practice (ARP) provides recommendations for design and test requirements for quantity measuring hydraulic fuses. 1.1 Purpose The recommended requirements contained in this ARP are compiled for inclusion, as applicable, in a Procurement Specification for this type of hydraulic fuse. NOTES: 1. The recommended requirements in this ARP should be reviewed by the procuring activity and only those requirements that are applicable for a specific application should be incorporated in the Procurement Specification. 2.
Standard

Commercial Aircraft Hydraulic System Sizing

2013-08-12
WIP
ARP6277
This document provides guidelines for sizing commercial aircraft hydraulic systems including determining the hydraulic flow demands for all phases of flight and hence sizing of the hydraulic pumps. In addition, details of sizing of hydraulic reservoirs and pipelines are also provided.
Standard

Sizing Considerations for Electrohydrostatic Actuation Pumps and Motors

2015-10-29
WIP
ARP6352
Recommendations for EHA Pump and Motor sizing based on considerations for various actuator performance requirements, including no-load speed, breakout torque, low temperature, stiffness, dynamic response, maximum pressure-velocity capability, and other conditions.
Training / Education

Introduction to Cooling Airflow Systems Web Seminar RePlay

Anytime
Vehicle functional requirements, diesel emission regulations, and subsystem thermal limits all have a direct impact on the design of a powertrain cooling airflow system. Severe duty cycles, minimal ram air, fouling, and sometimes unconventional package layouts present unique challenges to the designer. This course introduces many airflow integration issues and vehicle-level trade-offs that effect system performance and drive the design. The goal of this course is to introduce engineers and managers to the basic principles of diesel cooling airflow systems for commercial and off-road vehicles.
Technical Paper

Installation Effects on the Flow Generated Noise From Automotive Electrical Cooling Fans

2020-09-30
2020-01-1516
With the electrification of road vehicles comes new demands on the cooling system. Not the least when it comes to noise. Less masking from the driveline and new features, as for example, cooling when charging the batteries drives the need for silent cooling fans. In this work a novel e-fan is studied in different generalized installations and operating conditions. The fans (a cluster configuration) are installed in a test rig where the operation could be controlled varying the speed, flow rate and pressure difference over the fan. On the vehicle side of the fan a generalized packaging space (similar to an engine bay for conventional vehicles) is placed. In this packaging space different obstruction can be placed to simulate the components and radiators used in the vehicle. Here generalized simple blocks in different configuration are used to provide well defined and distinct test cases.
Technical Paper

Numerical Investigation of Narrow-Band Noise Generation by Automotive Cooling Fans

2020-09-30
2020-01-1513
Axial cooling fans are commonly used in electric vehicles to cool batteries with high heating load. One drawback of the cooling fans is the high aeroacoustic noise level resulting from the fan blades and the obstacles facing the airflow. To create a comfortable cabin environment in the vehicle, and to reduce exterior noise emission, a low-noise installation design of the axial fan is required. The purpose of the project is to develop an efficient computational aeroacoustics (CAA) simulation process to assist the cooling-fan installation design. This paper reports the current progress of the development, where the narrow-band components of the fan noise is focused on. Two methods are used to compute the noise source. In the first method the source is computed from the flow field obtained using the unsteady Reynolds-averaged Navier-Stokes equations (unsteady RANS, or URANS) model.
Technical Paper

Reinforcement of Low-Frequency Sound by Using a Panel Speaker Attached to the Roof Panel of a Passenger Car

2020-09-30
2020-01-1570
The woofer in a car should be large to cover the low frequencies, so it is heavy and needs an ample space to be installed in a passenger car. The geometry of the woofer should conform to the limited available space and layout in general. In many cases, the passengers feel that the low-frequency contents are not satisfactory although the speaker specification covers the low frequencies. In this work, a thin panel is installed between the roof liner and the roof panel, and it is used as the woofer. The vibration field is controlled by many small actuators to create the speaker and baffle zones to avoid the sound distortion due to the modal interaction. The generation of speaker and baffle zones follows the inverse vibro-acoustic rendering technique. In the actual implementation, a thin acrylic plate of 0.53ⅹ0.2 m2 is used as the radiator panel, and the control actuator array is composed of 16 moving-coil actuators.
Book

Principles of Engine Cooling Systems, Components and Maintenance

1990-10-01
Completely revised as a result of the significant progress made in cooling system design and maintenance practices and procedures, HS-40 provides current, comprehensive information on the description, function, and maintenance of engine liquid-cooling systems used in light and heavy-duty vehicles. Information-packed chapters discuss the interrelation between the cooling system and other engine systems, cooling system components, general preventive maintenance, and troubleshooting.