Training / Education

Design for Manufacturing & Assembly

Design for Manufacturing and Assembly (DFM+A), pioneered by Boothroyd and Dewhurst, has been used by many companies around the world to develop creative product designs that use optimal manufacturing and assembly processes. Correctly applied, DFM+A analysis leads to significant reductions in production cost, without compromising product time-to-market goals, functionality, quality, serviceability, or other attributes. This seminar will include information on how DFM+A fits in with QFD, Concurrent Engineering, Robust Engineering, and other disciplines.
Training / Education

Design for Manufacturing & Assembly (DFM/DFA)

2019-06-26
Design for Manufacturing and Assembly (DFM+A), pioneered by Boothroyd and Dewhurst, has been used by many companies around the world to develop creative product designs that use optimal manufacturing and assembly processes. Correctly applied, DFM+A analysis leads to significant reductions in production cost, without compromising product time-to-market goals, functionality, quality, serviceability, or other attributes. In this two-day seminar, you will not only learn the Boothroyd Dewhurst Method, you will actually apply it to your own product design!
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design - Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
1.1 This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. 1.2 This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. 1.3 Engine block heaters are 120 VAC devices that are used on a multitude of vehicle platforms in addition to trucks with sleeper cabs. Generally, the engine block heater circuit is wired independent of hotel loads.
Standard

Cartridge Cavity

2018-10-30
CURRENT
J2494/4_201810
This SAE Standard covers complete general and dimensional data for the manufacture of, T6061-T6 Aluminum cavities designed to receive Push To Connect threadless fittings known as “cartridges“, for air brake applications. This document is not intended to specify or recommend any style or manufacture of such cartridges but to establish uniform cavity dimensions for interchangeability purposes.
Standard

Cartridge Cavity

2011-10-28
HISTORICAL
J2494/4_201110
This SAE Standard covers complete general and dimensional data for the manufacture of, T6061-T6 Aluminum cavities designed to receive Push To Connect threadless fittings known as “cartridges“, for air brake applications. This document is not intended to specify or recommend any style or manufacture of such cartridges but to establish uniform cavity dimensions for interchangeability purposes.
Standard

Steel Self-Drilling Tapping Screws

2013-04-16
CURRENT
J78_201304
This SAE Standard covers the dimensional and general specifications, including performance requirements, for carbon steel self-drilling tapping screws suitable for use in general applications. It is the objective of this document to insure that carbon steel self-drilling tapping screws, by meeting the mechanical and performance requirements specified, shall drill a hole and form or cut mating threads in materials into which they are driven without deforming their own thread and without breaking during assembly. Appendix A is included to provide a recommended technique for measuring the case depth on the screws.
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2011-02-04
CURRENT
J2772_201102
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC-Module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 [CO2] and R-1234yf [HFO-1234yf], but the general techniques described here can be used for other refrigerants as well.
Standard

Top Speed Test Procedure for Electric Motorcycles

2014-02-21
CURRENT
J3007_201402
This SAE Recommended Practice incorporates a track-based test procedure that produces a representative value for vehicle top speed when operating on a level paved road with a fully charged battery.
Standard

Accelerated Exposure of Automotive Exterior Materials Using a Controlled Irradiance Water-Cooled Xenon Arc Apparatus

2008-01-11
CURRENT
J1960_200801
This test method specifies the operating procedures for a controlled irradiance, water-cooled xenon arc apparatus used for the accelerated exposure of various automotive exterior materials. This standard is limited to the models of xenon arc test apparatus specified in the Section on Apparatus. All other models of xenon arc test apparatus must use SAE J2527 to perform the test conditions specified in SAE J1960. SAE J2527 is the performance standard based on the test parameters of SAE J1960. Use of xenon arc test apparatus to perform SAE J2527 must be agreed upon by contractual parties.
Standard

Air Dryer Test Procedure

2012-11-09
CURRENT
J2384_201211
This SAE Recommended Practice establishes uniform Test Procedures for desiccant Air Dryers used in vehicles with compressed air systems per SAE J2383. Continuous flow desiccant Air Dryers are excluded from the scope of this document.
Standard

SAE MANUAL ON BLAST CLEANING

1968-06-01
CURRENT
J792A_196806
Blast cleaning may be defined as a secondary manufacturing process in which a suitable stream of solid particles is propelled with sufficient velocity against a work surface to cause a cleaning or abrading action when it comes in contact with the workpiece. As indicated in the definition, blast cleaning may be employed for a variety of purposes. Ordinarily, it is considered as a method for removing sand from castings, burrs or scale from forgings, mill products, or heat treated parts; to promote machinability, and to minimize the possibility of interference in actual operation. In addition to this use, blast cleaning also produces an excellent surface for industrial coatings. All these objectives are often accomplished in the one operation.
Standard

Brake Master Cylinder Plastic Reservoir Assembly for Road Vehicles

1994-06-01
HISTORICAL
J2053_199406
This SAE Recommended Practice specifies the performance test procedures and requirements of a plastic reservoir assembly suitable for use on a hydraulic brake master cylinder (reference SAE J1153). Intended usage is for on-road vehicles using brake fluid conforming to fMVSS-116 (DOT 3), and SAE J1703 specifications. This document includes the cap.cover and diaphragm as integral parts of the reservoir assembly. The fluid level sensor (FLS) is also included as an integral part of the assembly. However, additional FLS standards and/or requirements are applicable and necessary which are not covered in this document. This document is intended to provide a recommended practice and minimum performance requirements of current established designs on those reservoir assemblies generally used by individual manufacturers which have demonstrated satisfactory field performance. This document is applicable to new reservoir assemblies for commercial or aftermarket production.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2015-09-22
CURRENT
J968/2_201509
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2002-12-20
HISTORICAL
J968/2_200212
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Standard

Brake System Road Test Code - Passenger Car and Light-Duty Truck

2013-03-28
CURRENT
J843_201303
This SAE Recommended Practice establishes a uniform procedure for the level road test of the brake systems of new light-duty trucks and new multipurpose passenger vehicles1 up to and including 2700 kg (6000 lb) GVW and all classes of new passenger cars.