Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Evaluation of 5th Percentile Female Hybrid III Thoracic Biofidelity during Out-of-Position Tests with a Driver Air Bag

1998-02-23
980636
This paper evaluates the biofidelity of the Hybrid III 5th percentile female dummy relative to seven small female cadavers tested as out-of-position drivers in static air bag deployment tests. In the out-of-position tests, the chest was positioned against the air bag module in an effort to recreate a worst-case loading environment for the thorax. Two pre-depowered production air bags and a prototype dual-stage air bag were evaluated. Thoracic accelerometers and chestbands were used to compare chest compression, velocity, acceleration, and Viscous Criteria. A statistical comparison of dummy and cadaver results indicate acceptable biofidelity of the Hybrid III dummy with significant differences observed only in the Viscous Criteria.
Technical Paper

The Development, Validation and Application of a Finite Element Upper Extremity Model Subjected to Air Bag Loading

2003-10-27
2003-22-0004
Both frontal and side air bags can inflict injuries to the upper extremities in cases where the limb is close to the air bag module at the time of impact. Current dummy limbs show qualitatively correct kinematics under air bag loading, but they lack biofidelity in long bone bending and fracture. Thus, an effective research tool is needed to investigate the injury mechanisms involved in air bag loading and to judge the improvements of new air bag designs. The objective of this study is to create an efficient numerical model that exhibits both correct global kinematics as well as localized tissue deformation and initiation of fracture under various impact conditions. The development of the model includes the creation of a sufficiently accurate finite element mesh, the adaptation of material properties from literature into constitutive models and the definition of kinematic constraints at articular joint locations.
X