Technical Paper

Detection of Gasoline Vehicles with Gross PM Emissions

2007-04-16
2007-01-1113
Light duty gasoline vehicles (LDGV) are estimated to contribute 40% of the total on-road mobile source tailpipe emissions of particulate matter (PM) in California. While considerable efforts have been made to reduce toxic diesel PM emissions going into the future, less emphasis has been placed on PM from LDGVs. The goals of this work were to characterize a small fleet of visibly smoking and high PM emitting LDGVs, to explore the potential PM-reduction benefits of Smog Check and of repairs, and to examine remote sensing devices (RSD) as a potential method for identifying high PM emitters in the in-use fleet. For this study, we recruited a fleet of eight vehicles covering a spectrum of PM emission levels. PM and criteria pollutant emissions were quantified on a dynamometer and CVS dilution tunnel system over the Unified Cycle using standard methods and real time PM instruments.
Technical Paper

Investigation of Ultrafine Particle Number Measurements from a Clean Diesel Truck Using the European PMP Protocol

2007-04-16
2007-01-1114
The sampling protocol proposed by the international PMP program for determination of particle emissions from clean light-duty vehicles was applied to the emissions from a California heavy-duty trap-equipped diesel truck. CARB is interested in developing opinions about the potential of this new European approach for emission determination and in exploring its utility for use in California. In this exercise, the use of various commercially available instruments for counting and sizing particles in the context of the PMP recommendations are explored. A single vehicle on a chassis dynamometer was exercised over steady-state and transient cycles. Multiple measurements of gaseous, mass, and particle emissions were collected in order to determine statistical significance. The PMP approach yielded particle emission measurements with higher precision and accuracy than the reference mass-based emission measurement.
Technical Paper

Greenhouse Gas Emissions of MY 2010 Advanced Heavy Duty Diesel Engine Measured Over a Cross-Continental Trip of USA

2013-09-08
2013-24-0170
The study was aimed at assessing in-use emissions of a USEPA 2010 emissions-compliant heavy-duty diesel vehicle powered by a model year (MY) 2011 engine using West Virginia University's Transportable Emissions Measurement System (TEMS). The TEMS houses full-scale CVS dilution tunnel and laboratory-grade emissions measurement systems, which are compliant with the Code of Federal Regulation (CFR), Title 40, Part 1065 [1] emissions measurement specifications. One of the specific objectives of the study, and the key topic of this paper, is the quantification of greenhouse gas (GHG) emissions (CO2, N2O and CH4) along with ammonia (NH3) and regulated emissions during real-world operation of a long-haul heavy-duty vehicle, equipped with a diesel particulate filter (DPF) and urea based selective catalytic reduction (SCR) aftertreatment system for PM and NOx reduction, respectively.
Technical Paper

Transient Ultrafine Particle Emission Measurements with a New Fast Particle Aerosol Sizer for a Trap Equipped Diesel Truck

2005-10-24
2005-01-3800
The California Air Resources Board (CARB) has tested the utility of the Model 3090 Engine Exhaust Particle Sizer (EEPS™) by TSI in measuring pre- and post-trap particulate matter (PM) emissions from a medium-duty truck. Pre- and post-trap measurements are used to evaluate the effect of engine operation on PM emissions and trap effectiveness. Because of mounting evidence that ultrafine (UF) particles are harmful, regulatory agencies are investigating new and promising instrumentation for improved characterization of such particles in emissions. This is especially true for fast-response instruments that can be used to size-resolve real-time UF emissions from prominent sources such as diesel engines. The EEPS uses diffusion charging, electrical mobility segregation, and electrometers. It is designed for the number measurement of transient aerosols in the size range of 5.6 to 560 nm. It collects 10 measurements per second at a flow rate of 10 lpm.
Technical Paper

Emissions Correlation Between a Partial-Flow Diluter and The Full-Flow Constant Volume Sampler (CVS) for a Heavy-Duty Vehicle Under Steady-State Operation

2005-10-24
2005-01-3798
The California Air Resources Board (CARB) examined the performance of a Partial Flow Sampling System (PFSS) against a reference Constant Volume Sampling (CVS) system in measuring emissions from a heavy-duty vehicle (HDV) during dynamometer testing at CARB's Stockton Heavy-Duty Emissions Laboratory (SL). The SL PFSS system is a Sierra BG-2 system that uses flow-based (rather than CO2-based) dilution. The CVS system uses the University of California, Riverside's (UCR) Mobile Emissions Laboratory (MEL). The test vehicle was a 2000 model-year HD tractor powered by a CAT C-15 engine. Exhaust samples were collected simultaneously with the SL and MEL systems and analyzed for total particulate matter (PM), oxides of nitrogen (NOx), carbon dioxide (CO2), carbon monoxide (CO), and total hydrocarbons (THC). The samples were taken during steady-state vehicle operation. Each test mode was repeated seven times in each of two patterns: consecutive and sequential.
Technical Paper

Evaluation of Gravimetric Method to Measure Light-Duty Vehicle Particulate Matter Emissions at Levels below One Milligram per Mile (1 mg/mile)

2014-04-01
2014-01-1571
The California Air Resources Board (CARB) adopted the Low Emission Vehicle (LEV) III regulations in January 2012, which lowered the particulate matter (PM) emissions standards for light-duty vehicles (LDVs) from 10 milligrams per mile (10 mg/mile) to 3 mg/mile beginning with model year (MY) 2017 and 1 mg/mile beginning with MY 2025. To confirm the ability to measure PM emissions below 1 mg/mile, a total of 23 LDVs (MY pre-2004 to 2009) were tested at CARB's Haagen-Smit Laboratory (HSL) (10 LDVs) and the United States Environmental Protection Agency's (US EPA) National Vehicle and Fuel Emissions Laboratory (NVEFL) (13 LDVs) using the federal test procedure (FTP) drive schedule. One LDV with PM emissions ranging from 0.6 - 0.8 mg/mile was tested at three CARB HSL test cells to investigate intra-lab and inter-lab variability. Reference, trip, and tunnel filter blanks were collected as part of routine quality control (QC) procedures.
Technical Paper

Determination of Suspended Exhaust PM Mass for Light-Duty Vehicles

2014-04-01
2014-01-1594
This study provides one of the first evaluations of the integrated particle size distribution (IPSD) method in comparison with the current gravimetric method for measuring particulate matter (PM) emissions from light-duty vehicles. The IPSD method combines particle size distributions with size dependent particle effective density to determine mass concentrations of suspended particles. The method allows for simultaneous determination of particle mass, particle surface area, and particle number concentrations. It will provide a greater understanding of PM mass emissions at low levels, and therefore has the potential to complement the current gravimetric method at low PM emission levels. Six vehicles, including three gasoline direct injected (GDI) vehicles, two port fuel injected (PFI) vehicles, and one diesel vehicle, were tested over the Federal Test Procedure (FTP) driving cycle on a light-duty chassis dynamometer.