Refine Your Search

Topic

Author

Search Results

Journal Article

Mars Science Laboratory Mechanically Pumped Fluid Loop for Thermal Control - Design, Implementation, and Testing

2009-07-12
2009-01-2437
The Mars Science Laboratory (MSL) mission to land a large rover on Mars is being prepared for Launch in 2011. A Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) on the rover provides an electrical power of 110 W for use in the rover and the science payload. Unlike the solar arrays, MMRTG provides a constant electrical power during both day and night for all seasons (year around) and latitudes. The MMRTG dissipates about 2000 W of waste heat to produce the desired electrical power. One of the challenges for MSL Rover is the thermal management of the large amount of MMRTG waste heat. During operations on the surface of Mars this heat can be harnessed to maintain the rover and the science payload within their allowable limits during nights and winters without the use of electrical survival heaters. A mechanically pumped fluid loop heat rejection and recovery system (HRS) is used to pick up some of this waste heat and supply it to the rover and payload.
Journal Article

Design Description and Initial Characterization Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

2009-07-12
2009-01-2419
NASA's proposed lunar lander, Altair, will be exposed to vastly different external temperatures following launch till its final destination on the moon. In addition, the heat rejection is lowest at the lowest environmental temperatures (0.5 kW @ 4K) and highest at the highest environmental temperature (4.5 kW @ 215K). This places a severe demand on the radiator design to handle these extreme turn-down requirements. A radiator with digital turn-down capability is currently under study at JPL as a robust means to meet the heat rejection demands and provide freeze protection while minimizing mass and power consumption. Turndown is achieved by independent control of flow branches with isolating latch valves and a gear pump to evacuate the isolated branches. A bench-top test was conducted to characterize the digital radiator concept. Testing focused on the demonstration of proper valve sequencing to achieve turn-down and recharge of flow legs.
Technical Paper

Development of the Third Generation JPL Electronic Nose for International Space Station Technology Demonstration

2007-07-09
2007-01-3149
The capabilities of the JPL Electronic Nose have been expanded to include characteristics required for a Technology Demonstration schedule on the International Space Station (ISS) in 2008-2009 [1,2]. Concurrently, to accommodate specific needs on ISS, the processes, tools and analyses which influence all aspects of development of the device have also been expanded. The Third Generation ENose developed for this program uses two types of sensor substrates, newly developed inorganic and organic sensor materials, redesigned electronics, onboard near real-time data analysis and power and data interfaces specifically for ISS. This paper will discuss the Third Generation ENose with a focus on detection of mercury in the parts-per-billion range.
Technical Paper

Overview of the Vehicle Cabin Atmosphere Monitor, a Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and CEV

2007-07-09
2007-01-3150
Work is underway to deliver an instrument for analysis of the atmosphere aboard the International Space Station. The Vehicle Cabin Atmosphere Monitor (VCAM) is based on a low-mass, low-power miniature preconcentrator gas chromatograph/mass spectrometer (PCGC/MS) capable of providing sub-ppm measurements of volatile constituents in a space vehicle or outpost. VCAM is designed to operate autonomously, maintenance-free, once per day, with its own carrier and calibration gas supplies sufficient for a one-year lifetime. VCAM performance is sufficient to detect and identify 90% of the target compounds specified at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. The flight units will be delivered in mid-2008 and be operated in the ISS EXPRESS rack.
Technical Paper

Viral Populations within the International Space Station's Internal Active Thermal Control System Ground Support and Potential Flight Hardware

2007-07-09
2007-01-3108
The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) contains an aqueous, alkaline fluid (pH 9.5±0.5) that aids in maintaining a habitable environment for the crew. Because microbes have significant potential to cause disease, adverse effects on astronaut health, and microbe-induced corrosion, the presence of both bacteria and viruses within IATCS fluids is of concern. This study sought to detect and identify viral populations in IATCS samples obtained from the Kennedy Space Center as a first step towards characterizing and understanding potential risks associated with them. Samples were concentrated and viral nucleic acids (NA) extracted providing solutions containing 8.87-22.67 μg NA per mL of heat transfer fluid. After further amplification viral DNA and cDNA were then pooled, fluorescently labeled, and hybridized onto a Combimatrix panvira 12K microarray containing probes for ∼1,000 known human viruses.
Technical Paper

Mars Pathfinder Active Heat Rejection System: Successful Flight Demonstration of a Mechanically Pumped Cooling Loop

1998-07-13
981684
One of the new technologies successfully demonstrated on the recent Mars Pathfinder mission was the active Heat Rejection System (HRS). This system consisted of a mechanically pumped cooling loop, which actively controlled the temperatures of the various parts of the spacecraft. A single phase Refrigerant 11 liquid was mechanically circulated through the lander and cruise electronics box heat exchangers. This liquid transferred the excess heat to an external radiator on the cruise stage. This is the first time in unmanned spacecraft history that an active heat rejection system of this type has been used on a long duration spacecraft mission. Pathfinder was launched in December 1996 and landed on the Martian surface on July 4, 1997. The system functioned flawlessly during the entire seven months of flight from Earth to Mars. A life test set up of the cooling loop was used to verify the life of the system.
Technical Paper

Sojourner Mars Rover Thermal Performance

1998-07-13
981685
The Sojourner Rover landed on the surface of Mars on July 4, 1997 as part of the Mars Pathfinder Mission. The mission lasted almost three months during which the thermal design of the Rover was tested. This paper summarizes the Rover's design and performance as well as post-mission model correlation.
Technical Paper

Monitoring Space Shuttle Air for Selected Contaminants Using an Electronic Nose

1998-07-13
981564
A miniaturized electronic nose has been constructed at JPL in collaboration with Caltech. This array of conductometric sensors has been trained to detect and quantify the presence of vapors in the air; the compounds detected have been found as contaminants in shuttle air. This device has potential application as a miniature, distributed device for monitoring and controlling the constituents in air.
Technical Paper

Results from the Vehicle Cabin Atmosphere Monitor: A Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and Orion

2008-01-29
2008-01-2045
Progress on the delivery of the Vehicle Cabin Atmosphere Monitor (VCAM) is reported. VCAM is an autonomous trace-species detector to be used aboard the International Space Station (ISS) for atmospheric analysis. The instrument is based on a low-mass, low-power miniature preconcentrator, gas chromatograph, and Paul ion trap mass spectrometer (PCGC/MS) capable of measuring volatile constituents in a space vehicle or planetary outpost at sub-ppm levels. VCAM detects and quantifies 40 target compounds at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. It is designed to operate autonomously, maintenance-free, with a self-contained carrier and calibration gas supplies sufficient for a one-year lifetime. Two flight units will be delivered for operation in the ISS EXPRESS rack.
Technical Paper

On-Orbit Performance of the TES Loop Heat Pipe Heat Rejection System

2008-06-29
2008-01-2000
Launched on NASA's Aura spacecraft on July 15, 2004, JPL's Tropospheric Emission Spectrometer (TES) has been operating successfully for over three years in space. TES is an infrared high resolution, imaging fourier transform spectrometer with spectral coverage of 3.3 to 15.4 μm to measure and profile essentially all infrared-active molecules present in the Earth's lower atmosphere. It measures the three-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. The Aura spacecraft was successfully placed in a sun-synchronous near-circular polar orbit with a mean altitude of 705 km and 98.9 minute orbit period. The observatory is designed for a nominal 5 year mission lifetime. The instrument thermal design features include four temperature zones needed for efficient cryogenic staging to provide cooling at 65 K, 180 K, 230 K and 300 K.
Technical Paper

Thermal Vacuum Testing of the Moon Mineralogy Mapper Instrument

2008-06-29
2008-01-2037
The Moon Mineralogy Mapper (M3) instrument is scheduled for launch in 2008 onboard the Indian Chandrayaan-1 spacecraft. The mission is managed by the Indian Space Research Organization (ISRO) in Bangalore, India and is India's first flight to the Moon. M3 is being developed for NASA by the Jet Propulsion Laboratory under the Discovery Program Office managed by Marshall Space Flight Center. M3 is a state-of-the-art instrument designed to fulfill science and exploratory objectives. Its primary science objective is to characterize and map the lunar surface composition to better understand its geologic evolution. M3's primary exploration goal is to assess and map the Moon mineral resources at high spatial resolution to support future targeted missions. M3 is a cryogenic near infrared imaging spectrometer with spectral coverage of 0.4 to 3.0 μm at 10 nm resolution with high signal to noise ratio, spatial and spectral uniformity.
Technical Paper

Thermal Vacuum Testing of the Orbiting Carbon Observatory Instrument

2008-06-29
2008-01-2036
The Orbiting Carbon Observatory (OCO) instrument is scheduled for launch onboard an Orbital Sciences Corporation LEOStar-2 architecture spacecraft in December 2008. The instrument will collect data to identify CO2 sources and sinks and quantify their seasonal variability. OCO observations will permit the collection of spatially resolved, high resolution spectroscopic observations of CO2 and O2 absorption in reflected sunlight over both continents and oceans. OCO has three bore-sighted, high resolution, grating spectrometers which share a common telescope with similar optics and electronics. A 0.765 μm channel will be used for O2 observations, while the weak and strong CO2 bands will be observed with 1.61 μm and 2.06 μm channels, respectively. The OCO spacecraft circular polar orbit will be sun-synchronous with an inclination of 98.2 degrees, mean altitude of 705 km and 98.9 minute orbit period.
Technical Paper

Thermal Strategy for the Phoenix Robotic Arm Deployment

2009-07-12
2009-01-2438
The Mars Scout Phoenix Lander successfully landed in the Martian northern latitude on May 25, 2008. The Robotic Arm, which was designed to dig and to transfer soil samples to other Lander instruments, contained a number of actuators that had specific operational windows on the Martian surface due to the bearing lubricant. The deployment of the Robotic Arm was planned for Sol 2 (Mars days are referred to “Sols”). A few weeks before Mars landing, the Robotic Arm operations team learned that a strict flight rule had been imposed. It specified that the deployment shall be accomplished when the actuators were at or above −25°C since the deployment activity was qualified with the actuators at −40°C. Furthermore, the deployment plan identified a window of opportunity between 13:00 Local Solar Time (LST, equivalent to dividing the Sol into 24 equal Martian hours) and 15:30 LST.
Technical Paper

Operation of Third Generation JPL Electronic Nose on the International Space Station

2009-07-12
2009-01-2522
The Third Generation ENose is an air quality monitor designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 – 30 °C, relative humidity from 25 – 75% and pressure from 530 to 760 torr. This device was installed and activated on ISS on Dec. 9, 2008 and has been operating continuously since activation. Data are downlinked and analyzed weekly. Results of analysis of ENose monitoring data show the short term presence of low concentration of alcohols, octafluoropropane and formaldehyde as well as frequent short term unknown events.
Technical Paper

Thermal Performance Evaluation of a Small Loop Heat Pipe for Space Applications

2003-07-07
2003-01-2688
A Small Loop Heat Pipe (SLHP) featuring a wick of only 1.27 cm (0.5 inches) in diameter has been designed for use in spacecraft thermal control. It has several features to accommodate a wide range of environmental conditions in both operating and non-operating states. These include flexible transport lines to facilitate hardware integration, a radiator capable of sustaining over 100 freeze-thaw cycles using ammonia as a working fluid and a structural integrity to sustain acceleration loads up to 30 g. The small LHP has a maximum heat transport capacity of 120 Watts with thermal conductance ranging from 17 to 21 W/°C. The design incorporates heaters on the compensation chamber to modulate the heat transport from full-on to full-stop conditions. A set of start up heaters are attached to the evaporator body using a specially designed fin to assist the LHP in starting up when it is connected to a large thermal mass.
Technical Paper

Operational Thermal Control of Cassini Titan Flybys

2003-07-07
2003-01-2685
The Cassini spacecraft will make 45 targeted flybys of Saturn's largest moon, Titan. 25 flybys will have a relatively low closest approach target altitude in Titan's atmosphere. An operational thermal control strategy has been developed for these flybys. The challenge met was to provide flyby operational thermal control that enabled science and remained within design limitations and Project constraints. Thermal engineers adopted a Systems-level approach that insured appropriate risk mitigation and information accuracy. This paper focuses on the technical thermal control evaluation and strategy, the Systems-level approach taken, and lessons learned and recommendations in an operations environment.
Technical Paper

Trace Gas Analyzer for Extra-Vehicular Activity

2001-07-09
2001-01-2405
The Trace Gas Analyzer (TGA, Figure 1) is a self-contained, battery-powered mass spectrometer that is designed for use by astronauts during extravehicular activities (EVA) on the International Space Station (ISS). The TGA contains a miniature quadrupole mass spectrometer array (QMSA) that determines the partial pressures of ammonia, hydrazines, nitrogen, and oxygen. The QMSA ionizes the ambient gas mixture and analyzes the component species according to their charge-to-mass ratio. The QMSA and its electronics were designed, developed, and tested by the Jet Propulsion Laboratory (1,2). Oceaneering Space Systems supported JPL in QMSA detector development by performing 3D computer for optimal volumetric integration, and by performing stress and thermal analyses to parameterize environmental performance.
Technical Paper

Development of Vapor Phase Hydrogen Peroxide Sterilization Process for Spacecraft Applications

2001-07-09
2001-01-2411
In order to meet microbial reduction requirements for all Mars in-situ life detection and sample return missions, entire planetary spacecraft (including planetary entry probes and planetary landing capsules) may have to be exposed to a qualified sterilization process. At JPL, we are developing a low temperature (~45°C) vapor phase hydrogen peroxide sterilization process. This process is currently being used by the medical industry and its effectiveness is well established. In order to effectively and safely apply this technology to sterilize a spacecraft, which is made out of various man-made materials and electronic circuit boards, the following technical issues need to be resolved: 1. Efficacy of sterilization process. 2. Diffusion of H2O2 under sterilization process conditions into hard to reach places. 3. Materials and components compatibility with the sterilization process. 4. Development of methodology to protect (isolate) sensitive components (i.e. electronic ) from H2O2 vapor.
Technical Paper

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

2002-07-15
2002-01-2503
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration.
Technical Paper

Design and Flight Qualification of a Paraffin-Actuated Heat Switch for Mars Surface Applications

2002-07-15
2002-01-2275
The Mars Exploration Rover (MER) flight system uses mechanical, paraffin-actuated heat switches as part of its secondary battery thermal control system. This paper describes the design, flight qualification, and performance of the heat switch. Although based on previous designs by Starsys Research Corporation1,2, the MER mission requirements have necessitated new design features and an extensive qualification program. The design utilizes the work created by the expansion of a paraffin wax by bringing into contact two aluminum surfaces, thereby forming a heat conduction path. As the paraffin freezes and contracts, compression springs separate the surfaces to remove the conduction path. The flight qualification program involved extensive thermal performance, structural, and life testing.
X