Refine Your Search

Search Results

Viewing 1 to 9 of 9
Journal Article

Mars Science Laboratory Mechanically Pumped Fluid Loop for Thermal Control - Design, Implementation, and Testing

2009-07-12
2009-01-2437
The Mars Science Laboratory (MSL) mission to land a large rover on Mars is being prepared for Launch in 2011. A Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) on the rover provides an electrical power of 110 W for use in the rover and the science payload. Unlike the solar arrays, MMRTG provides a constant electrical power during both day and night for all seasons (year around) and latitudes. The MMRTG dissipates about 2000 W of waste heat to produce the desired electrical power. One of the challenges for MSL Rover is the thermal management of the large amount of MMRTG waste heat. During operations on the surface of Mars this heat can be harnessed to maintain the rover and the science payload within their allowable limits during nights and winters without the use of electrical survival heaters. A mechanically pumped fluid loop heat rejection and recovery system (HRS) is used to pick up some of this waste heat and supply it to the rover and payload.
Journal Article

Start-Up Characteristics and Gravity Effects on a Medium/High-Lift Heat Pump using Advanced Hybrid Loop Technology

2008-06-29
2008-01-1959
Thermal characterization was performed on a vapor compression heat pump using a novel, hybrid two phase loop design. Previous work on this technology has demonstrated its ability to provide passive phase separation and flow control based on capillary action. This provides high quality vapor to the compressor without relying on gravity-based phase separation or other active devices. This paper describes the subsequent work done to characterize evaporator performance under various startup scenarios, tilt angles, and heat loads. The use of a thermal expansion valve as a method to regulate operation was investigated. The effect of past history of use on startup behavior was also studied. Testing under various tilt angles showed evaporator performance to be affected by both adverse and favorable tilts for the given compressor. And depending on the distribution of liquid in the system upon startup, markedly different performance can result for the same system settings and heat loads.
Technical Paper

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

2002-07-15
2002-01-2503
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration.
Technical Paper

Design and Flight Qualification of a Paraffin-Actuated Heat Switch for Mars Surface Applications

2002-07-15
2002-01-2275
The Mars Exploration Rover (MER) flight system uses mechanical, paraffin-actuated heat switches as part of its secondary battery thermal control system. This paper describes the design, flight qualification, and performance of the heat switch. Although based on previous designs by Starsys Research Corporation1,2, the MER mission requirements have necessitated new design features and an extensive qualification program. The design utilizes the work created by the expansion of a paraffin wax by bringing into contact two aluminum surfaces, thereby forming a heat conduction path. As the paraffin freezes and contracts, compression springs separate the surfaces to remove the conduction path. The flight qualification program involved extensive thermal performance, structural, and life testing.
Technical Paper

Development Testing of a Paraffin-Actuated Heat Switch for Mars Rover Applications

2002-07-15
2002-01-2273
A paraffin-actuated heat switch has been developed for thermal control of the batteries used on the 2003 Mars Exploration Rovers. The heat switch is used to reject heat from the rover battery to a radiator. This paper describes the development test program designed, in part, to measure the thermal conductance of the heat switch in an 8 Torr CO2 environment over the expected operating temperature range of the battery. The switch has a closed conductance of about 0.6 W/°C and an open conductance of 0.019 W/°C. The test program also included measuring the battery temperature profile over a hot case and a cold case Mars diurnal cycle. The test results confirm that the battery will remain well within the upper and lower allowable flight temperatures in both cases.
Technical Paper

Mars Science Laboratory Thermal Control Architecture

2005-07-11
2005-01-2828
The Mars Science Laboratory (MSL1) mission to land a large rover on Mars is being planned for Launch in 2009. As currently conceived, the rover would use a Multi-mission Radioisotope Thermoelectric Generator (MMRTG) to generate about 110 W of electrical power for use in the rover and the science payload. Usage of an MMRTG allows for a large amount of nearly constant electrical power to be generated day and night for all seasons (year around) and latitudes. This offers a large advantage over solar arrays. The MMRTG by its nature dissipates about 2000 W of waste heat. The basic architecture of the thermal system utilizes this waste heat on the surface of Mars to maintain the rover's temperatures within their limits under all conditions. In addition, during cruise, this waste heat needs to be dissipated safely to protect sensitive components in the spacecraft and the rover.
Technical Paper

Mars Exploration Rover Heat Rejection System Performance – Comparison of Ground and Flight Data

2004-07-19
2004-01-2413
Mars Exploration Rover (MER) mission launched two spacecraft to Mars in June and July of 2003 and landed two rovers on Mars in January 2004. A Heat Rejection System (HRS) based on a mechanically pumped single-phase liquid cooling system was used to reject heat from electronics to space during the seven months cruise from Earth to Mars. Even though most of this HRS design was similar to the system used on Mars Pathfinder in 1996, several key modifications were made in the MER HRS design. These included the heat exchanger used in removing the heat from electronics, design of venting system used to vent the liquid prior to Mars entry, inclusion of pressure transducer in the HRS, and the spacecraft radiator design. Extensive thermal/fluids modeling and analysis were performed on the MER HRS design to verify the performance and reliability of the system. The HRS design and performance was verified during the spacecraft system thermal vacuum tests.
Journal Article

Development of Passively Actuated Thermal Control Valves for Passive Control of Mechanically Pumped Single-Phase Fluid Loops for Space Applications

2008-06-29
2008-01-2002
Passively activated thermal control valves were developed for use in a mechanically pumped single-phase fluid liquid loop (MPFL) of the Mars Science Laboratory (MSL) rover. A key approach to the thermal control of the rover with the fluid loop is to control the flow through the rover's heat generating or heat rejecting components. This is achieved by either splitting or mixing the fluid stream coming from different branches of the system at different temperatures; actively or passively controlled flow valves are typically used for such purposes. To meet the thermal control requirements of the Mars Science Laboratory (MSL) rover, a splitting and a mixing thermal control valves with gradual control capabilities using a linear thermal actuator and a spool was developed at Jet Propulsion Laboratory (JPL). The key feature of these control valves is the balancing of the flow through the various branches of the fluid loop in order to balance the heat loads of the whole thermal system.
Technical Paper

Two Phase vs. Single Phase Thermal Loop Trades for Exploration Mission LAT II Architecture

2008-06-29
2008-01-1958
NASA's Exploration Mission program is planning for a return to the Moon in 2020. The Exploration Systems Mission Directorate (ESMD)'s Lunar Architecture Team (LAT) is currently refining their lunar habitat architectures. The Advanced Thermal Control Project at the Johnson Space Center, as part of the Exploration Technology Development Program (ETDP) is developing technologies in support of the future lunar missions. In support of this project, a trade study was conducted at the Jet Propulsion Laboratory on the mechanically pumped two-phase and single-phase thermal loops for lunar habitats located at the South Pole for the LAT II architecture. This paper discusses the various trades and the results for a representative architecture which shares a common external loop for the single and two-phase system cases.
X