A swirl injector for GDI application was used to inject an iso-octane spray in a quiescent chamber, to study the effect of the air density on the spray behavior. Stroboscopic images are recorded at different delays from the injection trigger to study the spray shape and structure. The temporal evolution of different spray parameters, length, width, angle, volume, instantaneous global air-fuel ratio, is calculated from the images. The effect of the increasing air density is to shorten the time and length scale of the spray evolution.