Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Characterizing the Effect of Automotive Torque Converter Design Parameters on the Onset of Cavitation at Stall

2007-05-15
2007-01-2231
This paper details a study of the effects of multiple torque converter design and operating point parameters on the resistance of the converter to cavitation during vehicle launch. The onset of cavitation is determined by an identifiable change in the noise radiating from the converter during operation, when the collapse of cavitation bubbles becomes detectable by nearfield acoustical measurement instrumentation. An automated torque converter dynamometer test cell was developed to perform these studies, and special converter test fixturing is utilized to isolate the test unit from outside disturbances. A standard speed sweep test schedule is utilized, and an analytical technique for identifying the onset of cavitation from acoustical measurement is derived. Effects of torque converter diameter, torus dimensions, and pump and stator blade designs are determined.
Technical Paper

Testing Methods and Signal Processing Strategies for Automatic Transmission Transient Multiplexed Pressure Data

2019-06-05
2019-01-1500
Transmissions have multiple transient events that occur from gear shifting to torque converter clutch application. These transients can be difficult to capture and observe. A six speed front wheeled drive transmission was instrumented with pressure transducers to measure clutches and the torque converter. Due to size restrictions internal to the torque converter the data had to be multiplexed across three different transmitters. A method to capture a transient event through the use of multiplexed data was developed to create a data set with the transient event occurring on each channel. Once testing is completed, the data has to be split into individual channels and synced with the operational data. The data then can be used in both time and frequency domain analysis. It is important to understand that the data is not continuous and must be taken into consideration when post processing it for further results.
Technical Paper

Sound Power Measurement in a Semi-Reverberant, Volume Deficient Chamber

2015-06-15
2015-01-2359
Sound power can be determined using a variety of methods, but precision methods require the volume of the noise source to be less than 1% of the chamber volume leading to relatively large test chambers. Automotive torque converter performance and noise testing is completed in an enclosed metallic test fixture which inhibits the use of precision methods due to volume and space limitations. This paper describes a new method developed to accurately determine sound power of an automotive torque converter in a relatively small enclosure through characterization of the test environment. The test environment was characterized using two reference noise sources designed to represent torque converter noise output and physical geometry. Sound pressure levels of the sources were measured at multiple microphone locations and at three source amplitude levels to characterize the environment.
X