Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Development of a Supercooled Large Droplet Environment within the NRC Altitude Icing Wind Tunnel

2015-06-15
2015-01-2092
Simulations of supercooled large droplet (SLD) icing environments within the NRC's Altitude Icing Wind Tunnel (AIWT) have been performed in which broad band mass distribution spectra are achieved that include a distinct pattern of liquid water content (LWC) over a range of droplet sizes (i.e., bi-modal distribution). The mass distribution is achieved through modification of the existing spray system of the AIWT to allow two spray profiles with differing LWC and median volumetric diameter (MVD) to be simultaneously injected into the flow. Results of spray profile distributions measured in the test section have demonstrated that freezing drizzle conditions, where MVD is either less than or greater than 40 μm, can be achieved.
Technical Paper

Evaluation of Visual Failure versus Aerodynamic Limit for a Snow Contaminated Anti-Iced Wing Section during Simulated Takeoff

2019-06-10
2019-01-1972
Under contract to Airlines for America (A4A), APS Aviation Inc. (APS), in collaboration with the National Research Council of Canada (NRC), completed an aircraft ground icing exploratory research project at the NRC 3 m × 6 m Wind Tunnel in Ottawa in January 2019. The purpose of this project was to investigate the feasibility of using aerodynamic data to evaluate the performance of contaminated anti-icing fluid, rather than the traditional visual fluid failure indicators that are used to develop Holdover Times (HOTs). The aerodynamic performance of a supercritical airfoil model with anti-icing fluids and snow contamination was evaluated against the clean, dry performance of the airfoil in order to calculate the associated aerodynamic penalty. The visual failure of the fluid was also evaluated for each run, and the visual and aerodynamic results were compared against each other for each contamination exposure time.
Technical Paper

Measurement of Liquid Water Content for Supercooled Large Drop Conditions in the NRC’s Altitude Icing Wind Tunnel

2019-06-10
2019-01-2007
As a result of new regulations pertaining to the airworthiness of aircraft exposed to in-flight icing conditions where maximum water drop size is greater than 100 microns (referred to as Supercooled Large Droplet (SLD) conditions), updates are required to the test facilities and simulations that will enable manufactures to certify their products under these new rules. While a number of facilities report achieving some of the conditions specified in the new regulations, questions remain as to the suitability of the instrumentation used to measure the Liquid Water Content (LWC) and drop size distributions of the SLD icing cloud. This study aims to provide baseline LWC data through ice accretion measurement techniques on a NACA 0012 airfoil and rotating cylinders of varying diameters.
Technical Paper

Four Years of Testing to AS5562

2019-06-10
2019-01-1957
With the publication of SAE AS5562 in 2015, icing wind tunnel test facilities have upgraded their operating environments and instrumentation to meet the client demand to test to this new standard. Nearing four years of testing and development to this standard, numerous questions and challenges have arisen that industry has addressed on an individual basis but not in a common format for all. This paper addresses some of the known challenges in an effort to apply AS5562 consistently across industry and provide clarity to all users.