Technical Paper

Analysis of upper extremity response under side air bag loading

2001-06-04
2001-06-0016
Computer simulations, dummy experiments with a new enhanced upper extremity, and small female cadaver experiments were used to analyze the small female upper extremity response under side air bag loading. After establishing the initial position, three tests were performed with the 5th percentile female hybrid III dummy, and six experiments with small female cadaver subjects. A new 5th percentile female enhanced upper extremity was developed for the dummy experiments that included a two-axis wrist load cell in addition to the existing six-axis load cells in both the forearm and humerus. Forearm pronation was also included in the new dummy upper extremity to increase the biofidelity of the interaction with the handgrip. Instrumentation for both the cadaver and dummy tests included accelerometers and magnetohydrodynamic angular rate sensors on the forearm, humerus, upper and lower spine.
Technical Paper

A Pneumatic Airbag Deployment System for Experimental Testing

1997-02-24
970124
This paper examines an originally designed airbag deployment system for use in static experimental testing. It consists of a pressure vessel and valve arrangement with pneumatic and electric controls. A piston functions like a valve when operated and is activated pneumatically to release the air in the tank. Once released, the air fills the attached airbag. The leading edge velocity can be controlled by the initial pressure in the tank, which can range up to 960 kPa. Three different test configurations were studied, which resulted in leading edge deployment speeds of approximately 20 m/s, 40 m/s, and 60 m/s. In experiments using this system, seven types of airbags were tested that differed in their material, coating, and presence of a tether. Data for each series of tests is provided. High speed video and film were used to record the deployments, and a pressure transducer measured the airbag's internal pressure.
Technical Paper

Upper Extremity Interaction With a Helicopter Side Airbag: Injury Criteria for Dynamic Hyperextension of the Female Elbow Joint

2004-11-01
2004-22-0007
This paper describes a three part analysis to characterize the interaction between the female upper extremity and a helicopter cockpit side airbag system and to develop dynamic hyperextension injury criteria for the female elbow joint. Part I involved a series of 10 experiments with an original Army Black Hawk helicopter side airbag. A 5th percentile female Hybrid III instrumented upper extremity was used to demonstrate side airbag upper extremity loading. Two out of the 10 tests resulted in high elbow bending moments of 128 Nm and 144 Nm. Part II included dynamic hyperextension tests on 24 female cadaver elbow joints. The energy source was a drop tower utilizing a three-point bending configuration to apply elbow bending moments matching the previously conducted side airbag tests. Post-test necropsy showed that 16 of the 24 elbow joint tests resulted in injuries.