Refine Your Search

Search Results

Viewing 1 to 4 of 4
Journal Article

CFD Study of Ventilation and Carbon Dioxide Transport for ISS Node 2 and Attached Modules

2009-07-12
2009-01-2549
The objective of this study is to evaluate ventilation efficiency regarding to the International Space Station (ISS) cabin ventilation during the ISS assembly mission 1J. The focus is on carbon dioxide spatial/temporal variations within the Node 2 and attached modules. An integrated model for CO2 transport analysis that combines 3D CFD modeling with the lumped parameter approach has been implemented. CO2 scrubbing from the air by means of two ISS removal systems is taken into account. It has been established that the ventilation scheme with an ISS Node 2 bypass duct reduces short-circuiting effects and provides less CO2 gradients when the Space Shuttle Orbiter is docked to the ISS. This configuration results in reduced CO2 level within the ISS cabin.
Technical Paper

Integrated Computational Fluid Dynamics Carbon Dioxide Concentration Study for the International Space Station

2005-07-11
2005-01-2795
This paper reports results of Computational Fluid Dynamics (CFD) analysis of carbon dioxide (CO2) gradient variations in twelve ISS modules. Computations were performed using two 3D integrated models: one from the U.S. Laboratory to the forward end, and the other from the U.S. Laboratory to the aft end of the ISS. Operation of the CO2 removal systems and CO2 generation among six International Space Station (ISS) crewmembers' metabolic processes were included in the model. For several crew location scenarios, a detailed analysis of the CO2 gradients and time evolution in zones potentially occupied by astronauts is presented. In general, the paper gives an extended example of the application of CFD analysis to complex problems related to the quality of the cabin air.
Technical Paper

Analysis of Carbon Dioxide Concentration in the Shuttle Orbiter Middeck for the Launch on Need (LON) Mission

2005-07-11
2005-01-2799
This paper presents results of the CFD study aimed at evaluation of the CO2 concentration within the Shuttle Orbiter Middeck during the Launch on Need (LON) Crew Rescue flight. An assessment of the Middeck ventilation characteristics has been performed for two possible ventilation arrangements. A recommendation to use the ventilation system configuration with the open aft floor diffuser has been made on the basis of a three-dimensional airflow and CO2 gradient analysis.
Technical Paper

Air Circulation and Carbon Dioxide Concentration Study of International Space Station Node 2 with Attached Modules

2004-07-19
2004-01-2498
Crew health is dependent on the concentration of carbon dioxide in the atmosphere breathed. Often, models used for concentration have used the assumption that each module of the space station is well mixed, i.e. that the CO2 concentration is constant throughout the module. In this paper, Computational Fluid Dynamics (CFD) modeling is used to assess and validate the accuracy of that assumption. The concentration of carbon dioxide as calculated by CFD was compared to the concentration as calculated by a lumped parameter model. The assumption that the module is well mixed allows the use of relatively simple models, which can be developed and run quickly in order to support decisions for on-orbit analysis. CFD models generate more detailed information, such as CO2 gradients within the modules and airflow and mixing characteristics. However, CFD models, particularly transient models, take longer to develop and use.