Refine Your Search

Search Results

Viewing 1 to 9 of 9
Journal Article

Assessment of the Simulated Injury Monitor (SIMon) in Analyzing Head Injuries in Pedestrian Crashes

2012-04-16
2012-01-0569
Objectives. Examination of head injuries in the Pedestrian Crash Data Study (PCDS) indicates that many pedestrian head injuries are induced by a combination of head translation and rotation. The Simulated Injury Monitor (SIMon) is a computer algorithm that calculates both translational and rotational motion parameters relatable head injury. The objective of this study is to examine how effectively HIC and three SIMon correlates predict the presence of either their associated head injury or any serious head injury in pedestrian collisions. Methods. Ten reconstructions of actual pedestrian crashes documented by the PCDS were conducted using a combination of MADYMO simulations and experimental headform impacts. Linear accelerations of the head corresponding to a nine-accelerometer array were calculated within the MADYMO model's head simulation.
Technical Paper

American Automobile Manufacturers Association Heavy Truck Brake Tire Test

1995-11-01
952663
The objective of the American Automobile Manufacturers Association (AAMA) Heavy Truck Brake Tire Test was to evaluate how different tires might effect a vehicle's performance when tested per the Society of Automotive Engineers, Inc. (SAE) J1626 “Braking, Stability, and Control Performance Test Procedures for Air-Brake-Equipped Truck Tractors.” During the summer of 1991, the Motor Vehicle Manufacturer's Association (MVMA), now known as the American Automobile Manufacturer's Association (AAMA), contracted Transportation Research Center Inc. (TRC) to perform a Heavy Truck Round Robin Brake Test to evaluate the practicality and repeatability of the ABS test procedure developed for the Motor Vehicle Safety Research Advisory Committee of NHTSA (SAE Paper 922484). One of the conclusions derived from that test program was that tires seem to play a more significant role than expected in vehicle braking performance.
Technical Paper

Hybrid III 5th Female Neck Test Rotation Measurement

2005-04-11
2005-01-0303
Lab to lab differences in the testing of the Hybrid III 5th female dummy neck have led to the same neck passing in one lab and failing in another. Several indicators led to the hypothesis that the neck rotation measurement system is a critical factor in the differences observed. The Transportation Research Center Inc. and Denton ATD Inc. collaboratively conducted tests to understand the nature and importance of any differences obtained when different measurement devices are used. Dummy testing laboratories today use a neck rotation measurement system consisting of two rotary potentiometers, one attached to the neck/pendulum interface and one attached to the pivot pin which moves with the head of the dummy, plus a linkage between the two potentiometers (pots). The data from the two pots is summed for a total rotation. Neck testing was performed on two necks (of different manufacture) to investigate the effect of three rotation measurement assemblies' designs and masses.
Technical Paper

Development and Calibration of the Large Omnidirectional Child ATD Head Finite Element Model

2021-04-06
2021-01-0922
To improve the biofidelity of the currently available Hybrid III 10-year-old (HIII-10C) Anthropomorphic Test Device (ATD), the National Highway Traffic Safety Administration (NHTSA) has developed the Large Omnidirectional Child (LODC) ATD. The LODC head is a redesigned HIII-10C head with mass properties and modified skin material required to match pediatric biomechanical impact response targets from the literature. A dynamic, nonlinear finite element (FE) model of the LODC head has been developed using the mesh generating tool Hypermesh based on the three-dimensional CAD model. The material data, contact definitions, and initial conditions are defined in LS-PrePost and converted to LS-Dyna solver input format. The aluminum head skull is stiff relative to head flesh material and was thus modeled as a rigid material. For the actual LODC, the head flesh is form fit onto the skull and held in place through contact friction.
Technical Paper

Pressure-Based Abdominal Injury Criteria Using Isolated Liver and Full-Body Post-Mortem Human Subject Impact Tests

2011-11-07
2011-22-0012
Liver trauma research suggests that rapidly increasing internal pressure plays a role in liver injury. Previous work has shown a correlation between pressure and liver injury in pressurized ex vivo human livers when subjected to blunt impacts. The purpose of this study was to extend the investigation of this relationship between pressure and liver injury by testing full-body post-mortem human surrogates (PMHS). Pressure-related variables were compared with one another and also to previously proposed biomechanical predictors of abdominal injury. Ten PMHS were tested. The abdominal vessels were pressurized to physiological levels using saline, and a pneumatic ram impacted the right side of the specimen ribcage at a nominal velocity of 7.0 m/s. Specimens were subjected to either lateral (n = 5) or oblique (n = 5) impacts, and the impact-induced pressures were measured by transducers inserted into the hepatic veins and inferior vena cava.
Technical Paper

Biomechanical Responses of PMHS Subjected to Abdominal Seatbelt Loading

2016-11-07
2016-22-0004
Past studies have found that a pressure based injury risk function was the best predictor of liver injuries due to blunt impacts. In an effort to expand upon these findings, this study investigated the biomechanical responses of the abdomen of post mortem human surrogates (PMHS) to high-speed seatbelt loading and developed external response targets in conjunction with proposing an abdominal injury criterion. A total of seven unembalmed PMHS, with an average mass and stature of 71 kg and 174 cm respectively were subjected to belt loading using a seatbelt pull mechanism, with the PMHS seated upright in a free-back configuration. A pneumatic piston pulled a seatbelt into the abdomen at the level of the umbilicus with a nominal peak penetration speed of 4.0 m/s. Pressure transducers were placed in the re-pressurized abdominal vasculature, including the inferior vena cava (IVC) and abdominal aorta, to measure internal pressure variation during the event.
Technical Paper

The Large Omnidirectional Child (LODC) ATD: Biofidelity Comparison with the Hybrid III 10 Year Old

2016-11-07
2016-22-0017
When the Hybrid III 10-year old (HIII-10C) anthropomorphic test device (ATD) was adopted into Code of Federal Regulations (CFR) 49 Part 572 as the best available tool for evaluating large belt-positioning booster seats in Federal Motor Vehicle Safety Standard (FMVSS) No. 213, NHTSA stated that research activities would continue to improve the performance of the HIII-10C to address biofidelity concerns. A significant part of this effort has been NHTSA’s in-house development of the Large Omnidirectional Child (LODC) ATD. This prototype ATD is comprised of (1) a head with pediatric mass properties, (2) a neck that produces head lag with Z-axis rotation at the atlanto-occipital joint, (3) a flexible thoracic spine, (4) multi-point thoracic deflection measurement capability, (5) skeletal anthropometry representative of a seated child, and (6) an abdomen that can directly measure belt loading.
Technical Paper

Development of a Dynamic Nonlinear Finite Element Model of the Large Omnidirectional Child Crash Test Dummy

2024-04-09
2024-01-2509
The Large Omnidirectional Child (LODC) developed by the National Highway Traffic Safety Administration (NHTSA) has an improved biofidelity over the currently available Hybrid III 10-year-old (HIII-10C) Anthropomorphic Test Device (ATD). The LODC design incorporates enhancements to many body region subassemblies, including a redesigned HIII-10C head with pediatric mass properties, and the neck, which produces head lag with Z-axis rotation at the atlanto-occipital joint, replicating the observations made from human specimens. The LODC also features a flexible thoracic spine, a multi-point thoracic deflection measurement system, skeletal anthropometry that simulates a child's sitting posture, and an abdomen that can measure belt loading directly. This study presents the development and validation of a dynamic nonlinear finite element model of the complete LODC dummy. Based on the three-dimensional CAD model, Hypermesh was used to generate a mesh of the finite element (FE) LODC model.
Technical Paper

Comparison of the Responses of the Thorax and Pelvis of the GHBMC M50 -O Using Two Different Foam Materials in a High-Speed Rear Facing Frontal Impact Scenario

2024-04-09
2024-01-2647
Due to the lack of biofidelity seen in GHBMC M50-O in rear-facing impact simulations involving interaction with the seat back in an OEM seat, it is important to explore how the boundary conditions might be affecting the biofidelity and potentially formulate methods to improve biofidelity of different occupant models in the future while also maintaining seat validity. This study investigated the influence of one such boundary condition, which is the seat back foam material properties, on the thorax and pelvis kinematics and injury outcomes of the GHBMC 50th M50-O model in a high-speed rear-facing frontal impact scenario, which involves severe occupant loading of the seat back. Two different seat back foam materials were used – a stiff foam with high densification and a soft foam with low densification. The peak magnitudes of the T-spine resultant accelerations of the GHBMC M50-O increased with the use of soft foam as compared to stiff foam.
X