Refine Your Search

Search Results

Viewing 1 to 14 of 14
Journal Article

Measuring Diesel Ash Emissions and Estimating Lube Oil Consumption Using a High Temperature Oxidation Method

2009-06-15
2009-01-1843
Diesel engine ash emissions are composed of the non-combustible portions of diesel particulate matter derived mainly from lube oil, and over time can degrade diesel particulate filter performance. This paper presents results from a high temperature oxidation method (HTOM) used to estimate ash emissions, and engine oil consumption in real-time. Atomized lubrication oil and diesel engine exhaust were used to evaluate the HTOM performance. Atomized fresh and used lube oil experiments showed that the HTOM reached stable particle size distributions and concentrations at temperatures above 700°C. The HTOM produced very similar number and volume weighted particle size distributions for both types of lube oils. The particle number size distribution was unimodal, with a geometric mean diameter of about 23 nm. The volume size distribution had a geometric volume mean diameter of about 65 nm.
Technical Paper

Diesel Exhaust Particle Size: Measurement Issues and Trends

1998-02-23
980525
Exhaust particle number concentrations and size distributions were measured from the exhaust of a 1995 direct injection, Diesel engine. Number concentrations ranged from 1 to 7.5×107 particles/cm3. The number size distributions were bimodal and log-normal in form with a nuclei mode in the 7-15 nm diameter range and an accumulation mode in the 30-40 nm range. For nearly all operating conditions, more than 50% of the particle number, but less than 1% of the particle mass were found in the nuclei mode. Preliminary indications are that the nuclei mode particles are solid and formed from volatilization and subsequent nucleation of metallic ash from lubricating oil additives. Modern low emission engines produce low concentrations of soot agglomerates. The absence of these agglomerates to act as sites for adsorption or condensation of volatile materials makes nucleation and high number emissions more likely.
Technical Paper

Trade Study of an Exploration Cooling Garment

2008-06-29
2008-01-1994
A trade study was conducted with a goal to develop relatively high TRL design concepts for an Exploration Cooling Garment (ExCG) that can accommodate larger metabolic loads and maintain physiological limits of the crewmembers health and work efficiency during all phases of exploration missions without hindering mobility. Effective personal cooling through use of an ExCG is critical in achieving safe and efficient missions. Crew thermoregulation not only impacts comfort during suited operations but also directly affects human performance. Since the ExCG is intimately worn and interfaces with comfort items, it is also critical to overall crewmember physical comfort. Both thermal and physical comfort are essential for the long term, continuous wear expected of the ExCG.
Technical Paper

Cooling and Thermal Control Strategies in the Space Suit for Routine and Emergency Situations

2008-06-29
2008-01-1993
A series of demonstration studies were conducted with the aim of better understanding how to regulate body heat and thus enhance thermal comfort of astronauts during EVA requiring intensive physical exertion. The first study evaluated body zone heat transfer under different cooling temperatures in a liquid cooling garment (LCG), confirming the effectiveness of areas with high density tissue. The second study evaluated different configurations of hoods and neck scarves to maximize heat extraction from these key areas for heat release. The third study explored the possibility of regulating body heat by control of the water temperature circulating through selected body zones in the LCG, or blocking heat dissipation from particular body areas. The potential of heat insertion/removal from the head, hands, and feet to stabilize body comfort was evaluated in terms of the ability to advance this heat current “highway” from the core.
Technical Paper

Off-shoring EMS and the Barrier of Test-in-Reliability

2008-10-07
2008-01-2712
The history of off-road equipment manufacturing has been based on proven designs and long times between model updates. In sharp contrast with this strategy is the electronic manufacturing services (EMS) industry. The EMS industry is driven by the larger consumer product industry's continuing pressure for lower costs. Because of this, EMS tools, processes, and practices have evolved to support rapid technology and component changes. However the increasing consumer demand for features like better user-interfaces, more efficient fuel consumption, and the desire for increased operational controls in equipment have forced the off-road industry to increase the frequency of product updates to meet customers' needs. Equipment manufacturers make running changes leading to a “Learning-by-doing” development and manufacturing process. But rapid changes sometimes have an unpredictable impact on the reliability of the final product.
Technical Paper

The Influence of Engine Lubricating Oil on Diesel Nanoparticle Emissions and Kinetics of Oxidation

2003-10-27
2003-01-3179
Earlier work [1] shows that kinetics of Diesel soot oxidation is different from that of ethylene diffusion flame soot oxidation [2], possibly due to metals from lube oil. This study investigates the influence of metals on soot oxidation and the exhaust particle emissions using lube oil dosed fuel (2 % by volume). This method does not simulate normal lube oil consumption, but is used as a means of adding metals to particles for oxidation studies. This study also provides insight into the effect of systems that mix lube oil with fuel to minimize oil change service. The HTO-TDMA (High Temperature Oxidation-Tandem Differential Mobility Analyzer) technique [1] was used to measure the surface specific oxidation rate of Diesel particles over the temperature range 500-750 °C. Diesel particles sampled from the exhaust stream of a Diesel engine were size segregated by differential mobility and oxidized in situ in air in a heated flow tube of known residence time and temperature profile.
Technical Paper

An Advanced Physiological Based Shortened Liquid Cooling/Warming Garment for Comfort Management in Routine and Emergency EVA

2002-07-15
2002-01-2413
The focus of this research is on the development of a more energy efficient shortened liquid cooling/warming garment (LCWG) based on physiological principles comparing the efficacy of heat transfer of different body zones; the capability of blood to deliver heat; individual muscle and fat body composition as a basis for individual thermal profiles to customize the zonal involvement of the garment; and the development of shunts to minimize or redirect the cooling/warming loop for different environmental conditions, physical activity levels, and emergency situations. The total length of tubing in the LCWG is approximately 35% less, and the weight decreased by 45% compared to the LCVG currently used in space.
Technical Paper

Comfort Management in Rest and Exercise Conditions in an Innovative Shortened Liquid Cooling/Warming Garment

2002-07-15
2002-01-2411
Comfort management in extreme environments is complex, requiring temperature stabilization of the body core and distal parts of the extremities. Examination of the capability of body zones to absorb and release heat can facilitate a solution to this problem. Using an experimental shortened liquid cooling/warming garment (LCWG), heat transfer effectiveness of different body zone combinations was assessed in rest and exercise conditions, at different levels of body heat deficit and intensities of physical exertion. Comfort stabilization in terms of minimum changes in core (Tc) and finger (Tfing) temperatures was achieved in exercise (200-400 W) at 18-22°C inlet water temperature in the following zonal combination: a portion of the torso, the internal thigh area covering the femoral artery, the forearm, neck, and part of the head.
Technical Paper

Informativeness of the Finger Temperature/Heat Flux as an Index of Human Thermal Status Under Local Cold Influences

2006-07-17
2006-01-2237
Introduction Human thermoregulation during EVA remains a challenge. The establishment of a high correlation between the thermal status of the fingers and the heat surplus/deficit in the body provides an index with potential to more effectively monitor and control the astronaut’s thermal status. This series of studies evaluated the changes in finger temperature (Tfing) trajectories in conditions relevant to EVA. Methods In different experiments, subjects were donned in a liquid cooling/warming garment (LCWG) that covered the full body surface except for the face and hands; they wore either a physiologically designed warming glove or the Phase VI glove. The experimental protocols were as follows: imposition of temperature differences in the left and right gloves; different thermal insulation levels of the gloves; sequential grasping of a highly cold rail in different glove conditions; placement of the finger thermistor on different sites of the finger.
Technical Paper

Applications of U.S.-Russian Expedition Research to Aerospace Settings

1996-07-01
961612
Psychological, group interaction, and task performance characteristics were evaluated in four polar expedition teams varying in national and gender composition. Leaders played a crucial role in promoting strong group cohesiveness and morale. North American members were more highly focused on achievement strivings, Russians on avoidance of failure. Gender differences in behavior were also evident. An all women's team demonstrated a high level of cooperativeness and social support of other team members. Across teams, anxiety, tension, and health concerns increased in the early stages of the expedition and decreased significantly at later stages. The overall findings indicate the need to focus on the interaction of personality, cultural, gender, and task performance demands in personnel selection and during long duration missions. Implications for the optimal design of space vehicles and habitats are discussed.
Technical Paper

Effect of Local Hand Thermal Insulation on Total and Local Comfort Under Different Levels of Body Heat Deficit

2005-07-11
2005-01-2977
Introduction: There are contradictory opinions regarding the contribution of local hand thermal insulation to support local and total comfort during extravehicular activity (EVA). Instead of a local correction by means of thermal insulation on the periphery of the body to prevent heat dissipation, it may be optimal to prevent heat dissipation from the body core. To examine such a concept, the effects of different insulation levels on the left and right hands on the heat flux and temperature mosaic on the hands was measured. These variables were assessed in relation to the level of heat deficit forming in the core organs and tissues. Methods: Six subjects (4 males, 2 females) were donned in a liquid cooling/warming garment (LCWG) that totally covered the body surface except for the face. Participants wore the Phase VI space gloves including the entire micrometeoroid garment (TMG) on the left hand, and the glove without the TMG on the right hand.
Technical Paper

Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfort During EVA

2004-07-19
2004-01-2347
The shortened liquid cooling/warming garment (SLCWG) developed by the University of Minnesota group was compared with the standard NASA liquid cooling/ventilating garment (LCVG) garment during physical exertion in comfort (24°C) and hot (35°C) chamber environments. In both environmental conditions, the SLCWG was just as effective as the LCVG in maintaining rectal temperature (Tre) in a thermal comfort range; sweat production on the face was less; and subjective perception of overall and local body comfort was higher. The findings indicate that the SLCWG produces the same or greater comfort level as that achieved with the LCVG's total coverage of the body surface.
Technical Paper

Maximal Conductive Heat Exchange through Different Body Zones in a Liquid Cooling/Warming Space Garment

2000-07-10
2000-01-2255
The maximal capability of several body areas to absorb/release heat by varying the circulating water temperature in different zones of a multi-compartment liquid cooling/warming garment (LCWG) was explored. The goal was to identify the areas that are highly effective to stabilize body comfort, and to use this information for developing a more physiologically-based design of the space suit. The results showed a high capability of the upper compared to the lower body in the conductive heat exchange process. The involvement of the head in this process is still problematic, because there was not a high level of direct heat absorption/release through the cooling/warming hood in the LCWG. Exclusion of the legs but with involvement of the feet in heat exchange had no effect on comfort of the distal parts of the extremities and core body status.
Technical Paper

Augmentation of Blood Circulation to the Fingers through Wrist Warming to Enhance Finger Comfort during Long-Duration EVA

1999-07-12
1999-01-1969
This pilot study explored the effectiveness of local wrist warming as a potential countermeasure for providing finger comfort during extended duration EVA. Four subjects (3 males and 1 female) were evaluated in three different experimental conditions. Two additional body surface and wrist thermal conditions were evaluated on a smaller number of subjects. Wrist warming significantly increased finger temperature in ambient temperature. A clear positive effect to the fingers was evident when total body heat deficit was 30% of basal metabolic heat production in resting conditions. These initial findings indicate that wrist warming has considerable potential for increasing astronaut comfort during EVA while decreasing power requirements.
X