Refine Your Search

Topic

Search Results

Standard

MINIMUM STANDARD FOR OXYGEN PRESSURE REDUCERS

1991-09-01
HISTORICAL
AS1248
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2020-05-27
CURRENT
AS1248B
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

PORTABLE CHEMICAL OXYGEN

1993-11-01
HISTORICAL
AS1303
This specification applies to a chemical oxygen generator assembly for the following uses: a First aid treatment of passenger cabin occupants after emergency descent in a turbine engine powered airplane with pressurized cabin, as specified in FAR 121.333, Para. e (3). b By cabin attendants to maintain their mobility after cabin decompression.
Standard

Portable Chemical Oxygen

2011-06-21
HISTORICAL
AS1303A
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Portable Chemical Oxygen

2017-01-04
CURRENT
AS1303B
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

2004-06-23
HISTORICAL
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED

1971-07-01
HISTORICAL
AS1214
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2014-12-31
CURRENT
AIR1358C
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2003-10-15
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

STANDARD FOR OXYGEN FLOW INDICATORS

1966-07-01
HISTORICAL
AS916
This standard is intended to establish general material and design requirements for oxygen flow indicating devices. Flow indicators considered are for diluter-demand and continuous flow systems.
Standard

Introduction to Oxygen Equipment for Aircraft

2013-06-14
WIP
AIR825/1A
The purpose of this document is to give the reader an overview of the document package which makes up AIR825, Introduction to Oxygen Equipment for Aircraft, and a basic overview (see Section 4) of the operational concerns driven by human physiology during altitude exposure.
Standard

Reducers, Oxygen Pressure

2023-01-26
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.