This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semi closed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
This specification applies to a chemical oxygen generator assembly for the following uses: a First aid treatment of passenger cabin occupants after emergency descent in a turbine engine powered airplane with pressurized cabin, as specified in FAR 121.333, Para. e (3). b By cabin attendants to maintain their mobility after cabin decompression.
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
This specification covers the types of oxygen masks considered satisfactory for use in commercial transport aircraft at altitudes up to 25,000 ft. The types of masks covered are:
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
The scope of this document is to provide a list of specialized terms with their meanings. The glossary will assist the use of other documents related to aircraft oxygen equipment by defining ubiquitous terminology in context of this specialized field. The glossary contains terms of primary importance in the areas of chemistry, equipment, and physiology.
This document presents a glossary of many of the terms that can be found in literature covering issues related to aviation oxygen systems and associated topics. Such a listing can never be all inclusive but the majority of important terms are anticipated to be included for reference.
This Aerospace Information Report (AIR) defines words, terms, and specialized language used in describing the function, design, and operation of aircraft oxygen systems.
This document presents a glossary of many terms found in literature related to aviation oxygen systems and associated topics. Such a listing can never be all inclusive, but the majority of important terms are anticipated to be included for reference.