Refine Your Search

Topic

Search Results

Standard

AEROSPACE-PARTICLE COUNT DATA CONVERSION AND EXTRAPOLATION

1993-03-02
HISTORICAL
AIR877A
This Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

1993-03-02
HISTORICAL
AIR877B
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

2012-09-24
CURRENT
AIR877C
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

Secondary Filters for Fluid System Reliability

2000-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2014-06-03
CURRENT
ARP725B
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2003-06-05
HISTORICAL
ARP725A
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2011-12-19
CURRENT
ARP900B
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters for particle sizes equal to or greater than 5.0 μm and flows up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document.
Standard

Methods for Evaluating Cryogenic Filters

1992-06-29
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2018-08-13
CURRENT
ARP4285A
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2001-03-01
HISTORICAL
ARP4285
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid. A particular feature of this method is the membrane preparation to achieve an even particulate distribution on the membrane suitable for other applications. Membrane evaluation using standard membranes, described in this document, is an alternative technique to counting with either an optical microscope (ARP598) or an automatic particle counter (ISO 11500). The latter particle counting procedures are considered more precise.
Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2008-06-22
CURRENT
ARP599D
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.