Refine Your Search

Search Results

Viewing 1 to 19 of 19
Standard

Retainers, (Back-Up Rings), Hydraulic and Pneumatic, Polytetrafluoroethylene Resin, Solid, Static Gland

2005-12-14
HISTORICAL
AS5861
This SAE Aerospace Standard (AS) covers solid polytetrafluoroethylene (PTFE) retainers (back-up rings) for use in static glands in accordance with AS5857. They are for use in hydraulic and pneumatic system components as anti-extrusion devices in conjunction with O-rings, packings and other elastomeric seals. Because of the construction of groove dimensions, back-ups specific to rod applications are designated “R” - Rod (Female), back-ups specific to piston applications are designated “P” - Piston (Male). Retainers specified herein have been designed for a temperature range of -65 to 275 °F (-54 to 135 °C) and a nominal operating pressure of 3000 psi (20.6 MPa) for code 09 material and 5000 psi (34.3 MPa) for code 10 material. Material codes are based on AMS 3678 material types.
Standard

O-RING MOLDED FROM AMS-R-7362 NITRILE RUBBER MATERIAL

2021-09-15
CURRENT
AS29561C
THIS STANDARD ESTABLISHES THE DIMENSIONAL AND VISUAL QUALITY REQUIREMENTS, LOT REQUIREMENTS AND PACKAGING AND LABELING REQUIREMENTS FOR O-RINGS MOLDED FROM AMS-R-7362 NITRILE RUBBER. IT SHALL BE USED FOR PROCUREMENT PURPOSES.
Standard

Aerospace Rod Scraper Gland Design Standard

2020-11-03
CURRENT
AS4088F
This SAE Aerospace Standard (AS) defines gland details for scrapers for rod diameters from 1/4 to 15-1/2 inch (6.35 to 393.70 mm) inclusive, corresponding to AS568 O-ring Dash No. sizes -108/-111, -206/-222, -325/-349, and -425/-460. The gland details herein allow the use of more stable, efficient, and reliable scraper devices than MS33675 glands.
Standard

Aerospace Rod Scraper Gland Design Standard

2018-02-06
HISTORICAL
AS4088E
This SAE Aerospace Standard (AS) defines gland details for scrapers for rod diameters from 1/4 to 15-1/2 inch (6.35 to 393.70 mm) inclusive, corresponding to AS568 O-ring Dash No. sizes -108/-111, -206/-222, -325/-349, and -425/-460. The gland details herein allow the use of more stable, efficient and reliable scraper devices than MS33675 glands. NOTE: Scraper configurations are not specified in this document.