Refine Your Search

Search Results

Viewing 1 to 9 of 9
Standard

Coaxial Test Procedure to Measure the RF Shielding Characteristics of EMI Gasket Materials

2012-06-14
HISTORICAL
ARP1705B
The purpose of this procedure is to establish a technique for reliably and repeatedly measuring the RF shielding characteristics of EMI gasket materials and EMI gaskets against various joint surfaces. The procedure is also used to test the reliability of the gasketed joint combinations after being subjected to hostile environments.
Standard

Coaxial Test Procedure to Measure the RF Shielding Characteristics of EMI Gasket Materials

2022-06-24
CURRENT
ARP1705C
The purpose of this procedure is to establish a technique for reliably and repeatedly measuring the RF shielding characteristics of EMI gasket materials and EMI gaskets against various joint surfaces. The procedure is also used to test the reliability of the gasketed joint combinations after being subjected to hostile environments.
Standard

Recommended Insertion Loss Test Methods for EMI Power Line Filters

2012-08-10
CURRENT
ARP4244A
This document presents standard methods to evaluate the common mode and differential mode insertion loss of passive electromagnetic interference power line filters from 10 kHz through 10 GHz. Insertion loss test methods for both quality assurance and performance prediction purposes are described. The performance prediction tests are selected to more closely approximate operating impedances. They are not intended to be inclusive or to represent worst case conditions. However, the methodology of this document can be used to determine the performance in an arbitrary impedance circuit.
Standard

Control Plan/Technical Construction File

2013-03-25
CURRENT
ARP935B
This document contains a "sample" Control Plan with explanations as to the intended content of various sections. It also can serve as a sample technical construction file as specified by the European EMC Directive.
Standard

Control Plan/Technical Construction File

2003-09-04
HISTORICAL
ARP935A
This document contains a "sample" Control Plan with explanations as to the intended content of various sections. It also can serve as a sample technical construction file as specified by the European EMC Directive.
Standard

Electromagnetic Interference Measurement Antennas; Calibration Method

2021-09-01
CURRENT
ARP958E
This SAE Aerospace Recommended Practice outlines a standardized and economical method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room. This is the typical distance used in performing military EMC testing. The influence of the shield room on the measured field strength is not considered. This standard does not address the measurement of emissions from an unknown distributed source, yet it attempts to resemble reality by using another antenna, in the calibration method, that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with References 2.1 and 2.2. The purpose of Revision B was to include the calibration of other antennas, such as biconical, horn, monopole and small loop antennas that are also specified for use in these same references.
X