Refine Your Search

Topic

Search Results

Standard

ARC Fault Circuit Breaker ( AFCB), Aircraft, Trip-Free Single Phase and Three Phase 115 VAC, 400 Hz - Constant Frequency

2009-12-29
CURRENT
AS5692A
The primary function of this specification is to cover the general requirements for manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

ARC Fault Circuit Breaker (AFCB), Aircraft, Trip-Free Single Phase and Three Phase 115 VAC, 400 Hz - Constant Frequency

2015-02-11
WIP
AS5692B
The primary function of this specification is to cover the general requirements for manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

Electromechanical Power Controller/Relay, General Specification For

2016-01-08
CURRENT
AS5363A
This specification establishes general requirements for a family of trip-free Electromechanical Power Controller/Relays (EMPC) with electronic overcurrent sensing and control, intended for use in electrical systems conforming to RTCA, D0160 Revision C. These devices will be utilized for the protection of ac and/or dc electrical systems, bus feeders, and electrical equipment.
Standard

ARC Fault Circuit Breaker (AFCB), Aircraft, Trip-Free 28 VDC

2015-02-11
WIP
AS6019A
The primary function of this specification is to cover the general requirements for 28 VDC manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

ARC Fault Circuit Breaker (AFCB), Aircraft, Trip-Free 28 VDC

2012-06-06
CURRENT
AS6019
The primary function of this specification is to cover the general requirements for 28 VDC manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directly to the structure.
Standard

Circuit Breakers, Trip-Free, Aircraft General Specification For

2016-03-14
WIP
AS58091B
The primary function of this specification is to cover the general requirements of one-, two-, and three-pole trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements of one-, two- and three-pole circuit breakers for use in primary vehicles, other than aircraft, when mounted directly to the structure. An Amendment corresponding to this standard is available at AS58091_A1
Standard

Circuit Breakers, Trip-Free, Aircraft General Specification For

2012-05-31
CURRENT
AS58091A
The primary function of this specification is to cover the general requirements of one-, two-, and three-phase (often referred to as poles) trip-free circuit breakers for use in aircraft electric systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements of one-, two- and three-phase circuit breakers for use in primary vehicles, other than aircraft, when mounted directly to the structure.
X