Aircraft Ground Service Connections Locations and Type

2006-06-05
HISTORICAL
ARP4084A
The purpose of this SAE Aerospace Recommended Practice (ARP) is to standardize locations of aircraft ground service connections to accommodate the trend toward fixed systems, which use the passenger loading bridge as a vehicle for a source of utilities. It must be recognized that, in standardizing the locations of the aircraft service connections, they must continue to be served efficiently in those instances where mobile ground support equipment is used. There is an ever increasing number of fixed installations for aircraft servicing. The objectives to be met by standardizing the locations of the aircraft service connections are the following:
Standard

Method of Testing Pre-Conditioned Air Equipment

2021-04-08
CURRENT
ARP5374B
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

Method of Testing Pre-Conditioned Air Equipment

2008-04-15
HISTORICAL
ARP5374A
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

Method of Testing Pre-Conditioned Air Equipment

2001-12-07
HISTORICAL
ARP5374
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

Aircraft Markings for Ground Support Equipment Alignment

2020-04-24
CURRENT
AS6896
The purpose of this document is to provide a standard for aircraft fuselage markings located at the doors used for ground servicing operations. These markings can be used by all GSE that will dock at the aircraft. These markings may be used for one or several phases of the GSE positioning relative to the aircraft process: GSE alignment during approach, GSE final docking, and GSE auto leveling. It is not the purpose of this standard to describe the different technologies, cameras, or other equipment that can be mounted on GSE to utilize these markings. The aircraft that may use these markings will have a fuselage diameter of 3 m or more.
Standard

Airport Electrical Power System Harmonics

2020-09-23
CURRENT
AIR5387
This SAE Aerospace Information Report (AIR) is intended to cover all airport 50 or 60 Hz electrical systems as well as all electrical utilization equipment that is attached to those systems.
Standard

MAINTENANCE OF BATTERIES AND BATTERY CHARGING AND SERVICING FACILITIES

1992-06-10
HISTORICAL
AIR1898
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

Maintenance of Batteries and Battery Charging and Servicing Facilities

2020-09-23
CURRENT
AIR1898A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/ maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

400 Hz Connection Aircraft Electrical Maintenance Procedures

2008-03-28
HISTORICAL
AIR4365A
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

Measurement of Exterior Sound Level of Specialized Aircraft Ground Support Equipment

2006-10-13
HISTORICAL
ARP1801
The scope of this recommended practice covers specialized internal combustion engine powered equipment used in the support of aircraft operations. The equipment may be self-propelled, truck mounted, trailer mounted, skid mounted or stationary. It does not include construction equipment or equipment designed primarily for operation on highways or within factories or building areas.
Standard

Measurement of Exterior Sound Level of Specialized Aircraft Ground Support Equipment

2021-09-30
CURRENT
ARP1801A
The scope of this SAE Recommended Practice covers specialized internal combustion engine powered equipment used in support of aircraft operations. The equipment may be self-propelled, truck mounted, trailer mounted, skid mounted or stationary. It does not include construction equipment or equipment designed primarily for operation on highways or within factories or building areas. NOTE: Equivalent methodology is provided in (CEN) EN 1915-4, Aircraft ground support equipment - General requirements - Part 4: Noise measurement methods and reduction, to be used for measurements conforming to the EU Machinery Directive
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Ground Electrical Power Unit, Transportable 115/200 Volt AC (Nominal) 400 Hertz, 3-Phase 4-Wire (Grounded Neutral) Y-Connected System

2013-10-22
CURRENT
ARP1148B
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.